Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 42 for “"Swept-source OCT"”.
-
Spatially multiplexed swept source optical coherence tomography
… technique in optical coherence tomography (OCT) using a broadband frequency-tunable laser is presented for high-speed, high-resolution, depth-resolved imaging of tissue microstructure. Spectral domain techniques in OCT have become the focus of investigation in recent times due to its high …
-
Three-Dimensional Imaging Techniques for Biomedical Applications
… microscopy and Optical Coherence Tomography (OCT) stand out as two techniques offering high-resolution, non-invasive 3D visualization of living tissues and organisms. Chromatic confocal microscopy utilizes longitudinal chromatic aberration to conduct depth scans, facilitating high-resolution …
-
Επίπτωση κυστεοειδούς οιδήματος ωχράς κηλίδας σε γλαυκωματικούς ασθενείς μετά από επέμβαση καταρράκτη
… Hospital in Athens. The study utilized Swept Source OCT for measurements and found significant changes in choroidal thickness post-surgery. Purpose: The primary objective of this research was to examine the effect of cataract surgery on choroidal thickness and to investigate the …
-
Non-invasively measuring blood glucose by use of OCT
… with the optical coherence tomography (OCT) technique. Measurements on polystyrene microsphere solutions with dissolved glucose were carried out with an swept source OCT system. Physical averaging and wavelet filter denoising techniques were used to reduce speckles in the OCT images. …
-
Development of Extended-Depth Swept Source Optical Coherence Tomography for Applications in Ophthalmic Imaging of the Anterior and Posterior Eye
<p>Optical coherence tomography (OCT) is a non-invasive optical imaging modality that provides micron-scale resolution of tissue micro-structure over depth ranges of several millimeters. This imaging technique has had a profound effect on the field of ophthalmology, wherein it has become the …
-
Swept-Frequency Sampled Grating Distributed Bragg Reflector Lasers Optimized for Optical Coherence Tomography Applications
Swept Frequency Source Optical Coherence Tomography (OCT) requires high repetition rate and wide spectral width wavelength tunable sources at a low cost. The sampled grating distributed Bragg reflector (SG-DBR) laser provides wide wavelength tuning range while exhibiting a wavelength switching …
-
Development of a Dual Modality Swept Source Optical Coherence Tomography and Novel Frequency Domain Fluorescence Lifetime Imaging System Using Field Programmable Gate Arrays for Real Time Imaging of Ex-Vivo Human Coronary Artery Atherosclerotic Plaques
… in-vivo. Optical coherence tomography (OCT) and fluorescence lifetime imaging (FLIM) are optical imaging modalities that have the potential to extract complimentary morphological and biochemical information, respectively, from plaques without exogenous contrast agents. OCT has been used …
-
Optical coherence tomography methods using 2-D detector arrays
Optical coherence tomography (OCT) is a non-invasive, non-contact optical technique that allows cross-section imaging of biological tissues with high spatial resolution, high sensitivity and high dynamic range. Standard OCT uses a focused beam to illuminate a point on the target and detects the …
-
Development and application of Optical Coherence Tomography for the assessment of mammalian oocytes and embryos
… the application of optical coherence tomography (OCT) to the assessment of mammalian oocytes and early-stage embryos. A high-resolution spectral-domain OCT system was developed, and over 50 oocytes and embryos from several species were imaged. The results support a complementary role of OCT …
-
Development of Novel Optical Design and Signal Processing Approaches in Optical Coherence Imaging
<p>Optical coherence tomography (OCT) is a non-invasive optical imaging modality which can provide high-resolution, cross-sectional images of retina and cornea. It has become a standard of care in ophthalmology for the diagnosis and monitoring of ocular diseases. However, current OCT systems face …
-
Development of Optical Coherence Tomography (OCT) and OCT Angiography (OCTA) for Skin Applications
… aims to develop Optical Coherence Tomography (OCT) and OCT angiography (OCTA) techniques that can provide high-resolution microstructural and microvascular images from normal and pathological skin conditions in a non-invasive and in-vivo way. The research thesis also demonstrates the potential …
-
Development of Deep-learning-based Technologies for Optical Coherence Tomography (OCT) and OCT-Angiography in Clinical Applications
… trade-offs. Optical coherence tomography (OCT) and angiography (OCTA) offer non-invasive, high-resolution imaging (1-3 mm depth) for visualizing tissue microstructure and microvasculature without contrast agents, showing promise in dermatology and oral medicine. This thesis advances …
-
OPTICAL COHERENCE TOMOGRAPHY OPHTHALMIC SURGICAL GUIDANCE
Optical coherence tomography (OCT) performs high-resolution cross-sectional and volumetric tissue imaging in situ through the combination of confocal gating, coherence gating, and polarization gating. Because it is noninvasive, OCT has been used in multiple clinical applications such as tissue …
-
Source Development and Dispersion Measurements in Optical Coherence Tomography
OPTICAL coherence tomography (OCT) is a non-invasive imaging modality, which provides mm-deep cross sectional and volumetric images in real-time at micrometer resolution. Additional to its promising imaging capabilities it can provide label-free detection of flow in semi-transparent and translucent …
-
Development of Fourier Domain Optical Coherence Tomography for Applications in Developmental Biology
… available for use. Optical coherence tomography (OCT) is one such technology. OCT fills a niche between the high resolution of confocal microscopy and deep imaging penetration of ultrasound. Developmental studies of the chicken embryo heart are of great interest. Studies in mature hearts, …
-
Advances in Axial Motion-like Artefact correction in Optical Coherence Tomography Imaging
… back in the 1990s, Optical Coherence Tomography (OCT) has been an invaluable tool for biomedical imaging, more so in the area of ophthalmology, thanks to its ability to retrieve structural information from within a scattering sample in a non-destructive, non-invasive, and contactless way. …
-
Development of Dual-Modality Optical Imaging Systems Consisting of Optical Coherence Tomography and Fluorescence Lifetime Imaging Microscopy
… that incorporate Optical coherence Tomography (OCT) and Fluorescence Lifetime Imaging Microscopy (FLIM) for simultaneous characterization of tissue morphology and its biochemistry. In the first phase of the research, we combined spectral-domain OCT with FLIM that is designed for endogenous …
-
Sensors and structured beams in optical coherence tomography
Optical coherence tomography (OCT) is an emerging medical imaging technique that provides images of various tissue structures at micrometer scale resolution. A swept source laser which emits time-varying wavelengths light at a high-speed was developed that greatly improves OCT processing speed and …
-
Optical coherence tomography for retinal diagnostics
Optical Coherence Tomography (OCT) is a non-invasive three-dimensional imaging technique. OCT synthesizes a cross-sectional image from a series of lateral adjacent depth scans, and with a two-dimensional scanning scheme, three-dimensional intensity image of sample can be constructed. Due to its …
Page 1 of 3