Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 418 for “"Swir"”
-
Active Targeting in the SWIR and Extended SWIR
… environments such as smoke, haze, and fog. The SWIR and extended SWIR (eSWIR) imaging bands provide a balance between atmospheric scattering and absorption and diffraction-limited spot size, but are still subject to performance degradation when passive illumination is reduced. This has led to …
-
SWIR objective design using seidel aberration theory
… candidate of these operable wavebands is the SWIR (Shortwave infrared). Shortwave infrared (SWIR) imaging is an extension of Near Infrared (NIR) and visible (VIS) imaging applications and SWIR waveband is defined between 0.9-1.7 m for InGaAs SWIR detectors. SWIR radiation in the atmosphere is …
-
Active surface passivation for SWIR InGaAs photodetectors
… are noted. Lattice-matched short-wave infrared (SWIR) Indium-Gallium-Arsenide (InGaAs) grown on Indium-Phosphide (InP) sample with a cut-off wavelength of 1.7 μm is processed with wet etching of 30 μm pixel pitch to verify this claim. The proper operation of the photodetector is verified using …
-
Concentrateurs luminescents pour l'imagerie active dans le SWIR
La bande de longueurs d'onde SWIR (Short Wave Infrared 1 µm - 3 µm) est très intéressante en imagerie car elle permet de collecter des informations différentes et complémentaires de l'imagerie visible. Elle nécessite d'utiliser des sources d'éclairage spécifique qui, idéalement, sont des sources …
-
Antimonide-based SWIR avalanche photodiodes on InP substrates
… (SWaP-c) of the system. Commercially available SWIR APDs are demonstrated on cost-effective InP substrates using a separate absorption, charge, and multiplication (SACM) structure. These SACM APDs, featuring a mature In0.53Ga0.47As (InGaAs) absorber, exhibit high material quality, ease of …
-
SWIR Imaging and Echelle Spectroscopy via Compressive Sensing
A new sampling theory, called compressive sensing (CS), has recently emerged and its fundamental idea can be distilled as: it is possible to obtain near complete recovery of a signal/image from a small set of mixed measurements of it if the signal/image possesses properties akin to sparseness. …
-
Targeting Performance of SWIR/MWIR Superband Camera Systems
… superband contains both the short-wave infrared (SWIR) waveband – where most of the signal comes from reflected light – and mid-wave infrared (MWIR) waveband – where most of the signal comes from emitted light. It is commonly understood that in many cases, having more spectral information leads to …
-
Target detection and scene classification with VNIR/SWIR spectral imagery
… Imaging Spectrometer (NVIS), provides VNIR/SWIR (0.4-2.5 m) spectra, which are used to here to study such applications. NVIS has a nominal GSD of 0.5- 1.5 meters in operational modes utilized for this work, which make the data well suited for studying mapping and classification algorithms. …
-
Silicon CMOS and InGaAs(P)/InP SPADs for NIR/SWIR detection
… at near-infrared (NIR) and short-wave infrared (SWIR) wavelengths, such as quantum information science, biophotonics, space imaging, and light detection and ranging (LiDAR), have accelerated the development of NIR/SWIR single-photon detectors. Up to date, there have been various detector types …
-
Spectrométrie en Réflexion Diffuse dans le SWIR pour détection moléculaire non invasive
Le diabète est une maladie touchant un nombre croissant d'individu chaque année, près de 550 millions de personnes dans le monde aujourd'hui. Pour ces patients, le contrôle régulier du taux de glycémie est essentiel. Ce contrôle se fait de manière invasive, avec un implant ou par prélèvement de …
-
Développement de photodiodes InGaAs petit pas pixel pour la détection du SWIR
… d’image petit pas pixel en InGaAs pour le SWIR.La méthode traditionnelle de dopage des photodiodes InGaAs par diffusion de Zn présente des contraintes qui pourrait limiter la réduction du pas de pixel sous 5 µm. Cette thèse propose d’explorer deux méthodologies alternatives de dopage soit …
-
Development of a Multispectral VIS-SWIR Imaging Modality for Cutaneous Water Assessment
… reflectance imaging in the short-wave infrared (SWIR) spectrum is an effective method for quantitatively mapping relative cutaneous fluid content. Unlike the visible and near infrared spectra, the SWIR spectrum exhibits strong water absorption and relatively weak melanin absorption. Therefore, …
-
Advanced Silicon and SWIR Single-Photon Avalanche Diodes: Design, Simulation, and Characterization
… the near-infrared (NIR) and short-wave infrared (SWIR) regions due to their bandgap (1.1 eV) and since silicon is an indirect bandgap material. Extending SPAD's efficiency towards the NIR/SWIR region is a key requirement for eye-safe LiDAR and fiber optic-based telecommunication applications. This …
-
SIGNAL PROCESSING FOR SHORT WAVE INFRARED (SWIR) RAMAN SPECTROSCOPY DIAGNOSIS OF CANCER
… beyond 830 nm and short-wave infrared (SWIR) InGaAs Array detectors resulted in dramatically reduced auto-fluorescence. The unique characteristics of Raman signals collected from SWIR systems versus NIR Raman systems requires inspection of the suitability of spectral pre-processing …
-
VISIBLENEAR INFRARED (VNIR) AND SHORTWAVE INFRARED (SWIR) SPECTRAL VARIABILITY OF URBAN MATERIALS
The advent of relatively high spatial resolution hyperspectral imagery (HSI) provides a different perspective of the urban environment than lower spatial resolution hyperspectral data and either multispectral or panchromatic images. The objective of this thesis was to build and analyze a spectral …
-
Nouvelle génération de photodiodes à base de pérovskites pour la détection NIR-SWIR
… proche et courte bande infrarouge (NIR et SWIR).Dans un premier temps, un alliage des pérovskites halogénées plomb-étain a été évalué pour la détection dans le proche infrarouge (NIR). Un bilan bref est dessiné au travers d’une intégration dans des dispositifs photodiodes testées en …
-
On Designing Tattoo Registration and Matching Approaches in the Visible and SWIR Bands
… is using as an input raw Short-Wave Infrared (SWIR) band tattoo images and matches them successfully against their visible band counterparts. The SWIR tattoo images are captured at 1100 nm, 1200 nm, 1300 nm, 1400 nm and 1500 nm. After an empirical study where multiple photometric normalization …
-
Fabrication and Characterization of SWIR/eSWIR Dual-Band nBn InGaAs Focal Plane Arrays
… for extended short wavelength infrared (eSWIR) operating mode as %60 at 1.7 μm and the cut-off wavelength of the detector for eSWIR mode is 2.0 μm. For SWIR operation mode, %48 peak quantum efficiency is obtained at 1.5 μm and the cut-off wavelength for SWIR mode is 1.7 μm. These results …
-
Lead Sulfide colloidal quantum dot-based solution-processed short-wave infrared (SWIR) photodetector
… and fabrication of PbS CQD shortwave infrared (SWIR) photodetectors using a solution processed method. The synthesis involves the controlled reaction between lead oxide and oleic acid in a high-temperature solvent, followed by the addition of a stabilizing ligand (Hexamethyldisilathiane) …
Page 1 of 21