Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 70 for “"Symmetrical Components"”

  1. Islanding Detection of Grid Connected Distributed Generation Resources Using Symmetrical Components

    … method is based on the well-known theory of symmetrical components. Single variable threshold limit for islanding detection leads to incorrect results. As a result, a new mathematical formula with more than one variable has been implemented. In this dissertation, islanded and normal …

    calgary Repository record for Islanding Detection of Grid Connected Distributed Generation Resources Using Symmetrical Components (opens in a new tab)

  2. Novel Symmetrical Components-Based Methods for Protection of Systems with High-Level Penetration of IBRs

    … systems. The works employ various models using symmetrical components. The first work models a superimposed quantity to provide a new fault detection element for unbalanced faults. The element also provides a way to determine the direction of faults detected to improve selectivity. The second …

    ucf Repository record for Novel Symmetrical Components-Based Methods for Protection of Systems with High-Level Penetration of IBRs (opens in a new tab)

  3. Time-Domain Symmetrical Components for Detection and Analysis of Unbalanced Faults in Three-Phase Systems

    … approaches using phasor analysis and symmetrical components offer valuable steady-state insights but respond too slowly for transient or rapidly changing conditions. This thesis investigates time-domain symmetrical components (ISCs) as a faster, physically interpretable method for …

    calpoly Repository record for Time-Domain Symmetrical Components for Detection and Analysis of Unbalanced Faults in Three-Phase Systems (opens in a new tab)

  4. Monitoring and Control for Fault Ride-Through of Power grids and Microgrids using Phasor Estimator of Symmetrical Components

    … to observe the electrical grid and foresee unsymmetrical components in the occurrence of faults. This research steers towards improving fault detection and taking the required control strategies to suppress the unsymmetrical components in the power system, implementing the positive, negative, …

    ttu Repository record for Monitoring and Control for Fault Ride-Through of Power grids and Microgrids using Phasor Estimator of Symmetrical Components (opens in a new tab)

  5. Improved synchronous source modelling with particular reference to the development of high speed protection.

    … waves are studied. A new technique utilising symmetrical components and the Fourier transform to analyse a system containing a large turboalternator, generator transformer and a distributed parameter transmission line is developed and compared with time domain phase coordinate solutions.

    bath Repository record for Improved synchronous source modelling with particular reference to the development of high speed protection. (opens in a new tab)

  6. Earth Fault Distance Computation Methods Based on Transients in Power Distribution Systems

    … signals consist of many different frequency components, which result from charging and discharging of the network capacitances. The transient components provide valuable information for fault location purposes. The charging component has higher amplitude and lower frequency than the discharge …

    aalto Repository record for Earth Fault Distance Computation Methods Based on Transients in Power Distribution Systems (opens in a new tab)

  7. Sequence filters: A critical review of sequence filters, analysis of design principles and an experimental investigation of the transient response of selected filters

    … were developed from the mathematical theory of symmetrical components. Filters are systematically reviewed on this basis. Initially the elements required for the construction of filters are considered. Generalised theories for the basic filters are developed and design principles established. A …

    glasgow Repository record for Sequence filters: A critical review of sequence filters, analysis of design principles and an experimental investigation of the transient response of selected filters (opens in a new tab)

  8. Induction and permanent-magnet synchronous generators for small-scale power system applications

    … IG are proposed and analyzed. The method of symmetrical components is found to be a versatile tool for analyzing all the circuit configurations to be studied, including the Smith connection. Microcontroller-based multi-mode operation of an IG with the Smith connection is also investigated. …

    city-london Repository record for Induction and permanent-magnet synchronous generators for small-scale power system applications (opens in a new tab)

  9. CANONICAL REPRESENTATION OF A CLASS OF LINEAR DISCRETE-TIME TIME-VARIANT SYSTEMS

    … can also be interpreted as a (two dimensional) symmetrical component decomposition of [H ]. Since a sampled and quantized image can be represented by a matrix, an application involving image representation in terms of its symmetrical components is presented.

    sask Repository record for CANONICAL REPRESENTATION OF A CLASS OF LINEAR DISCRETE-TIME TIME-VARIANT SYSTEMS (opens in a new tab)

  10. Συμβολή στην ανάλυση του ηλεκτρικού και του μαγνητικού πεδίου στο περιβάλλον εναέριων γραμμών ηλεκτρικής ενέργειας

    … the analysis of the conductors’ charges in their symmetrical components, the description of the intensity of the electric field using double complex numbers and the use of multipole expansions to express the intensity of the electric field. The use of double complex numbers allows the simultaneous …

    greece Repository record for Συμβολή στην ανάλυση του ηλεκτρικού και του μαγνητικού πεδίου στο περιβάλλον εναέριων γραμμών ηλεκτρικής ενέργειας (opens in a new tab)

  11. DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY

    … beginning of this thesis. Distance relay using symmetrical components approach is one of the well established distance protection schemes. After a thorough analysis of the previously suggested algorithms, a combined algorithm of symmetrical components and compensation current scheme is …

    nus Repository record for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab)

  12. Algoritmos de proteção de distância para linhas de transmissão longas paralelas equilibradas

    … the obtained formulations has been proved using symmetrical components and graph theory, being the test systems modeled exactly like they were considered for the derivation of such algorithms. The applicability of the constant zero-sequence compensation parameters approach has also been attested, …

    brazil-ufmg Repository record for Algoritmos de proteção de distância para linhas de transmissão longas paralelas equilibradas (opens in a new tab)

  13. Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems

    … spectrum analysis (MCSA), negative sequence components analysis utilizing a symmetrical components transformation, and the space-vector pendulous oscillation method. The applicability of these diagnosis techniques to this case-study experimental interior permanent- magnet machine demonstrate …

    marquette Repository record for Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems (opens in a new tab)

  14. Fault Analysis and Protection of Doubly Fed Induction Generator-Based Wind Farms

    … circuit condition. Fault calculations using symmetrical components and factors which determine the fault current contribution are also discussed. A nine MW wind farm with six units of 1.5 MW DFIGs are modeled using Matlab/Simulink/SimPowerSystems and simulated for symmetrical and asymmetrical …

    okstate Repository record for Fault Analysis and Protection of Doubly Fed Induction Generator-Based Wind Farms (opens in a new tab)

  15. Control and operation of wind power plants connected to DC grids

    … consequently implies that control strategies in symmetrical components are considered. Furthermore, the reduction of over-modulation and over-voltages by the power converters in the offshore grid is dealt with.

    barcelona Repository record for Control and operation of wind power plants connected to DC grids (opens in a new tab)

  16. APPLICATION OF MODAL TRANSFORMATION FOR FAULT ANALYSIS AND DIGITAL DISTANCE RELAYING

    … Presently, electromechanical and solid state components are used for implementing distance relay schemes. During the past 15 years, the development of digital processor based relays has received considerable attention. The symmetrical and Clarke components are generally used for the analysis …

    sask Repository record for APPLICATION OF MODAL TRANSFORMATION FOR FAULT ANALYSIS AND DIGITAL DISTANCE RELAYING (opens in a new tab)

Page 1 of 4