Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Synchronized measurement"”.
-
Synchronized measurement data conditioning and real-time applications
<p>Phasor measurement units (PMU), measuring voltage and current phasor with synchronized timestamps, is the fundamental component in wide-area monitoring systems (WAMS) and reveals complex dynamic behaviors of large power systems. The synchronized measurements collected from power grid may degrade …
-
Synchronized Measurement of Machine Rotor Angle and Its Application
… installed on the shaft of a generator. With a synchronized angle measurement, accurate stability studies and wide-area controls can be implemented. The experimental setup for measuring the rotor angle of a generator is explained in this work. A wide-area power system stabilizer implementing the …
-
A New Method of Determining the Transmission Line Parameters of an Untransposed Line using Synchrophasor Measurements
… which the parameter values are calculated using synchronized voltage and current measurements from both ends of a transmission line. One of the biggest problems facing the synchronized measurement method is line transposition. Several methods have been proposed that demonstrate how the line …
-
A Study on Wide-area Measurement-based Approaches for Power System Voltage Stability
… (WAMS) enabled by the synchrophasor technology, measurement-based approaches for power system voltage stability and control have been widely discussed in recent years. Based on high-frequency synchronized measurement signals collected from phasor measurement units (PMUs), these approaches have …
-
Methods for Monitoring Electromechanical Oscillations in Power Systems
… can be monitored for example by using phasor measurement units (PMU). The development of wide area monitoring systems (WAMS) consisting of several PMUs has enabled the use of multiple synchronized measurement signals received from several locations in the power system to be used for the …
-
Evaluation and Standardizing of Phasor Data Concentrators
… major blackouts. In order to isolate the fault, measurements taken at different times throughout the blackout need to be collected and analyzed. With each measurement device having its own time source, time alignment can be a quite tedious and lengthy process. The need for a new time synchronized …
-
High-Resolution Time-Synchronized Monitoring and Anomaly Detection in Modern Distribution System
… frameworks by developing high-resolution, cross-synchronized fundamental and harmonic measurement techniques that assist system operators in more effectively extracting additional dynamic information in modern power distribution systems. The first half of the dissertation focuses on developing …
-
Measurement-Based Monitoring and Control in Power Systems with High Renewable Penetrations
… and control based on the increasingly available measurements are essential in assisting stable operation and effective planning for these evolving systems.</p> <p>First, awareness of the evolving dynamic characteristics is quintessential for secure operation and corrective planning. A quantified …
-
Despiking Velocimetric Data with 2D ARMA Models and the Role of Impulse in Sediment Movement on Variable Bed Slopes
… Lastly, a Proof of Concept is presented for synchronized measurement of fluid velocities and image recordings of particles along the bed. Automated algorithms track a particle of interest and determine the precise time of movement for correlation with the velocity time series. Overall, ARMA …
-
Measurements for Wide Area Monitoring, Protection, and Control systems: algorithms, instruments and architectures
… power grids. WAMPAC systems take advantage of synchronized measurement networks to provide a comprehensive view of grid dynamics over large geographical areas. By utilizing data from Phasor Measurement Units (PMUs), WAMPAC systems enable improved detection of grid disturbances, faster response …
-
Fault Detection on a Full-Scale OH-58 A/C Helicopter Transmission
… the planetary system does not allow for direct measurements of the sun gear. Instead, special measurement and data processing techniques are needed to filter out the effects of the planet gears, bearings, input spiral bevel stage, and other components in and around the gearbox. Planetary …
-
Synchronized Measurements And Applications During Power System Dynamics
Synchronized phasor measurements during dynamics tend to be affected by prevailing system frequency. Some major blackouts in power systems are indeed featured with very large frequency disturbance. Quantitative study done in this dissertation shows that small frequency disturbance may lead to …
-
Evaluation of key factors influencing a South African based electrical utility to utilise smart grid technologies for power quality management
… system. Finally, it is concluded that a need for synchronized measurement of power quality data in a wide area network exists for a South African utility, to allow comparison of PQ data measured at different network locations as though the measurement were all made by a single instrument. This …