Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 48 for “"Synchronized measurements"”.

  1. Fault Location in Transmission Systems Using Synchronized Measurements

    Compared with conventional measurements from supervisory control and data acquisition (SCADA) system, phasor measurement units (PMUs) provide time-synchronized and direct measurements of phasors. The availability of synchronized phasor measurements can significantly improve power system protection …

    uky-thes Repository record for Fault Location in Transmission Systems Using Synchronized Measurements (opens in a new tab)

  2. Synchronized Measurements And Applications During Power System Dynamics

    Synchronized phasor measurements during dynamics tend to be affected by prevailing system frequency. Some major blackouts in power systems are indeed featured with very large frequency disturbance. Quantitative study done in this dissertation shows that small frequency disturbance may lead to …

    vt Repository record for Synchronized Measurements And Applications During Power System Dynamics (opens in a new tab)

  3. Method of Modeling the Swing Equation Using Time Synchronized Measurements

    … from oscillations and transients using time-synchronized measurements can provide real-time information, including angular displacements, voltage and current phasors, frequency changes, and rate of signal system decay from positive-sequence components. Power system voltage and current …

    portland-state Repository record for Method of Modeling the Swing Equation Using Time Synchronized Measurements (opens in a new tab)

  4. Assessment of Cyber Vulnerabilities and Countermeasures for GPS-Time Synchronized Measurements in Smart Grids

    We aim at expanding the horizon of existing research on cyberattacks against the time-syncrhonized devices such as PMUs and PDCs, along with corresponding countermeasures. We develop a PMU-PDC cybersecurity testbed at Virginia Tech Power and Energy Center (PEC) lab. The testbed is able to simulate …

    vt Repository record for Assessment of Cyber Vulnerabilities and Countermeasures for GPS-Time Synchronized Measurements in Smart Grids (opens in a new tab)

  5. Synchronized measurement data conditioning and real-time applications

    … (PMU), measuring voltage and current phasor with synchronized timestamps, is the fundamental component in wide-area monitoring systems (WAMS) and reveals complex dynamic behaviors of large power systems. The synchronized measurements collected from power grid may degrade due to many factors and …

    utk-theses Repository record for Synchronized measurement data conditioning and real-time applications (opens in a new tab)

  6. Synchrophasor based method for computing the Thevenin equivalent impedance seen by a concentrated wind farm region

    … a line. Synchrophasors provide the advantage of synchronized measurements of phase angles which are essential in determining the transmission line reactance. This thesis provides the results of applying this model to estimate the Thevenin equivalent line reactance between McDonald Observatory in …

    texas Repository record for Synchrophasor based method for computing the Thevenin equivalent impedance seen by a concentrated wind farm region (opens in a new tab)

  7. The assessment of waveform distortion in power systems : validation of methods based on single–point measurements

    … design. Methods utilizing single-point measurements, usually taken at the Point of Common Coupling, for the assessment of the harmonic distortion generated by loads are continuously being published. It's been proven by means of computer simulations and laboratory experiments that in an …

    nwu-za Repository record for The assessment of waveform distortion in power systems : validation of methods based on single–point measurements (opens in a new tab)

  8. Phasor Measurement Units Applications Prioritization Based on Wide-Area Disturbance Events

    … frequency, among others. PMUs take these synchronized measurements as fast as 60 times per second; compared with the traditional 2-4 second SCADA measurements, PMUs bring a much clear and real-time picture of what is happening in the power system. PMUs have been increasingly deployed …

    vt Repository record for Phasor Measurement Units Applications Prioritization Based on Wide-Area Disturbance Events (opens in a new tab)

  9. IMPROVING NETWORK DIAGNOSTICS USING PROGRAMMABLE NETWORKS

    … DPTP: a time-synchronization protocol to enable synchronized measurements in the data-plane, 2) SyNDB: a framework which leverages DPTP to provide synchronized packet-level network-wide recording of events at data-plane to perform debugging, and 3) BNV: a scalable framework of creating arbitrary …

    nus Repository record for IMPROVING NETWORK DIAGNOSTICS USING PROGRAMMABLE NETWORKS (opens in a new tab) Download file for IMPROVING NETWORK DIAGNOSTICS USING PROGRAMMABLE NETWORKS (opens in a new tab)

  10. Programmable Network Approaches to Resilience and Security in Phasor Measurement Unit Networks

    … an important source of high-frequency, time-synchronized measurements that support wide-area monitoring, control, and protection. However, the growing complexity of smart grids and their reliance on real-time communication expose them to a range of cyber threats, including data loss, …

    arkansas Repository record for Programmable Network Approaches to Resilience and Security in Phasor Measurement Unit Networks (opens in a new tab)

  11. Voltage Stability Analysis Using Simulated Synchrophasor Measurements

    … Significant research have been focused on time-synchronized measurements of power systems which can be used to frequently determine the state of a power system and can lead to a more robust protection, control and operation performance. This thesis discusses the applicability of two voltage …

    calpoly Repository record for Voltage Stability Analysis Using Simulated Synchrophasor Measurements (opens in a new tab)

  12. Detection and Location of Faults in Wide Area Systems based on Error-Dependent Communication Strategy

    … every bus. Hence linear state estimator based on synchronized measurements is employed for estimating the state of the entire system. The estimated states of the system are then compared to a certain threshold and if any abnormality is found, fault is detected. Once the faulted bus is detected, …

    wvu Repository record for Detection and Location of Faults in Wide Area Systems based on Error-Dependent Communication Strategy (opens in a new tab)

  13. One millimeter for man, one meter for mankind: establishing millimeter wave radar as a ubiquitous sensor in consumer applications

    … only RGB-D (color and depth) aligned but also synchronized with inertial measurement unit (IMU) measurements in the presence of ego-motion. Moreover, having time-synchronized measurements allow for verification, automated or assisted labelling of the radar data, and opens the door for novel …

    uiuc Repository record for One millimeter for man, one meter for mankind: establishing millimeter wave radar as a ubiquitous sensor in consumer applications (opens in a new tab)

  14. Development and implementation of an open-box distribution-level phasor measurement unit

    … monitoring three-phase power. They provide synchronized measurements from any location where devices are installed. This synchronization is due to the micro-second Global Positioning System (GPS) time accuracy and is necessary for data to have meaning when compared across different …

    uiuc Repository record for Development and implementation of an open-box distribution-level phasor measurement unit (opens in a new tab)

  15. A New Method of Determining the Transmission Line Parameters of an Untransposed Line using Synchrophasor Measurements

    … which the parameter values are calculated using synchronized voltage and current measurements from both ends of a transmission line. One of the biggest problems facing the synchronized measurement method is line transposition. Several methods have been proposed that demonstrate how the line …

    vt Repository record for A New Method of Determining the Transmission Line Parameters of an Untransposed Line using Synchrophasor Measurements (opens in a new tab)

  16. Cascading Outages Detection and Mitigation Tool to Prevent Major Blackouts

    … Measurement Units, or PMUs that are taking synchronized measurements using the GPS clock signal. The PMUs can calculate time-synchronized phasor values of voltage and currents, frequency and rate of change of frequency. Such measurements, alternatively called synchrophasors, can be utilized …

    tamu Repository record for Cascading Outages Detection and Mitigation Tool to Prevent Major Blackouts (opens in a new tab)

  17. Sensing, communications and monitoring for the smart grid

    … wide area power grid monitoring based on synchronized measurements from newly developed devices such as phasor measurement units (PMUs), mode meters and so on. In addition, an optimal fusion technique is studied as a good foundation for detection in wireless sensor networks, with …

    colostate Repository record for Sensing, communications and monitoring for the smart grid (opens in a new tab)

  18. A comprehensive protection scheme for distribution systems

    … scheme, is illustrated in this thesis based on synchronized measurements. The method uses dynamic state estimation, based on the dynamic model of the component that accurately reflects the nonlinear characteristics of the component. Numerical experiments show that the protection of active …

    gatech Repository record for A comprehensive protection scheme for distribution systems (opens in a new tab)

  19. Real-time power system topology change detection and identification

    … is model-free, and exploits the high-speed synchronized measurements provided by phasor measurement units (PMUs). In this framework, a statistical quickest change algorithm is applied to the voltage phase angle measurements collected from PMUs to detect the change-point that corresponds to …

    uiuc Repository record for Real-time power system topology change detection and identification (opens in a new tab)

  20. Enhancing Smartgrid Situational Awareness and Resiliency to Data Attack using Dynamic State Estimation

    … angle and speed). With the advent of fast and synchronized measurements from Phasor Measurement Units and using dynamical state estimation tools such as Kalman filtering, it is now possible to estimated these nonlinear dynamical states (PSDSE). This dissertation is about improving situational …

    ttu Repository record for Enhancing Smartgrid Situational Awareness and Resiliency to Data Attack using Dynamic State Estimation (opens in a new tab)

Page 1 of 3