Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"Synchronous generator (SG)"”

  1. Modeling and performance analysis of artificial intelligence (AI) based controllers for AVR of a synchronous generator (SG)

    … voltage level at the stator terminals of a synchronous generator (SG). Hence, the voltage stability of a power system network is affected by AVR’s performance. Maintaining constancy and stability of the nominal voltage level in power systems remains a major control problem. Another critical …

    dut Repository record for Modeling and performance analysis of artificial intelligence (AI) based controllers for AVR of a synchronous generator (SG) (opens in a new tab)

  2. Modeling, Stability Analysis, and Control of Distributed Generation in the Context of Microgrids

    … the dynamics of the primary governor, generators, and their interfaces and controls. A new comprehensive investigation is also presented of the effects of system unbalance on the stability of distribution grids with DG units based on synchronous generator (SG) and doubly-fed induction …

    waterloo Repository record for Modeling, Stability Analysis, and Control of Distributed Generation in the Context of Microgrids (opens in a new tab)

  3. Estratégia Grid-Forming para geração eólica em microrredes utilizando regulador eletromagnético de frequência

    … approaches aim to emulate the behavior of a synchronous generator (SG) to mitigate these problems. In this context, the use of an Electromagnetic Frequency Regulator (EFR) emerges as a promising solution for wind power systems (WPS), as it enables the use of an SG in the connection to the …

    brazil-ufrn Repository record for Estratégia Grid-Forming para geração eólica em microrredes utilizando regulador eletromagnético de frequência (opens in a new tab)

  4. Three-Phase Power Converter Based Real-Time Synchronous Generator Emulation

    … the development and verification of a real-time synchronous generator (SG) emulator in the HTB. The research involved in this dissertation aims at designing a proper control to achieve emulator performance goal and investigating the sources of error and its influence on interconnected SG-emulator …

    utk-theses Repository record for Three-Phase Power Converter Based Real-Time Synchronous Generator Emulation (opens in a new tab)

  5. Stability of Frequency Regulation with a Grid Following Inverter

    … grid-connected and islanded operation with a synchronous generator (SG), while synthetic inertia stability limits were assessed only during grid-connected operation. Grid strength was varied through changes in the impedance between the inverter and the local grid connection. The stability …

    chalmers Repository record for Stability of Frequency Regulation with a Grid Following Inverter (opens in a new tab)

  6. Stability analysis of virtual synchronous machine control strategy in power system

    … In order to deal with this issue, virtual synchronous machine (VSM) control is proposed. Associated with such a solution, it is of great interest to know the impacts of VSM on power system stability, in particular, power system oscillations. Hence, the focus of this doctoral research work …

    birmingham Repository record for Stability analysis of virtual synchronous machine control strategy in power system (opens in a new tab)

  7. A virtual synchronous generator control in the power system with high penetration of renewable energies--weak grid!

    … experiencing a paradigm shift from conventional synchronous generators (SG) based systems to mixed generation systems with a large portion of renewable energies (RE). This has resulted in the erosion of the conventional power system’s frequency control. This is because, inertia of the system …

    whiterose Repository record for A virtual synchronous generator control in the power system with high penetration of renewable energies--weak grid! (opens in a new tab)

  8. Inertia Redressing Scheme for Power Grid with Renewable Energy Generation

    … and centralized generation that is equipped with synchronous generators. Different from these synchronous generators, most of the renewable energy generation does not provide the system with inertia, an essential system attribute that dominates the frequency response with respect to any …

    calgary Repository record for Inertia Redressing Scheme for Power Grid with Renewable Energy Generation (opens in a new tab)

  9. Stability analysis and robust control of power networks in stochastic environment

    … detailed higher order differential equations for synchronous generator (SG), wind turbine generator (WTG). The network power flow equations are expressed as algebraic equations. The resultant system is described by a detailed higher order nonlinear differential-algebraic model. It is shown that …

    iastate Repository record for Stability analysis and robust control of power networks in stochastic environment (opens in a new tab)

  10. Control Strategies for Minimizing the DC-Link Capacitance in Power Electronics Converters for Aircraft Electrical Power Systems

    … In main power generation, variable frequency generators (VFGs) generate VF AC supply (380-800Hz 115/230V) to feed frequency insensitive loads. The VF AC is also converted into DC (+/-270V or 540V) by using transformers and power electronics converters (PECs) to feed DC loads. The DC is further …

    houston Repository record for Control Strategies for Minimizing the DC-Link Capacitance in Power Electronics Converters for Aircraft Electrical Power Systems (opens in a new tab)