Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 38 for “"Synchrotron facility"”
-
OPTIMAL DESIGN OF THE MAGNET PROFILE FOR A COMPACT QUADRUPOLE ON STORAGE RING AT THE CANADIAN SYNCHROTRON FACILITY
This thesis concerns design of a quadrupole magnet for the next generation Canadian Light Source storage ring. The quality of the design is measured by the so-called width of Good Field Region (GFR) in the magnetic field generated by the magnet in a particular configuration, e.g. quadrupole …
-
Synchrotron electron beam control
… of electron beams for the optimal performance of synchrotrons. The techniques have been applied to Diamond Light Source, the UK's national synchrotron facility. Electron beam motion in synchrotrons is considered as a large-scale, two-dimensional process and by using basis functions, controllable …
-
The branching fraction of long-lived kaon going to muon-anti-muon
… National Laboratory Alternating Gradient Synchrotron facility. The apparatus consisted of a two-magnet mass spectrometer, together with dual electromagnetic and muon particle identification systems. A total of 281 $K\sb{L}\to\mu\bar{\mu}$ events were observed. Normalizing to the 15,768 …
-
A search for the rare decay kaon(L) going to muon/electron
… in the B5 beamline of the Alternating Gradient Synchrotron facility at the Brookhaven National Laboratory during the Spring, 1988 slow-extracted beam running period. The experiment was sensitive to approximately fifty million $\rm K\sb{L}\to\pi\pi$ decays. No $\rm K\sb{L}\to\mu e$ candidate …
-
Irradiation Studies of Astrophysical Ice Analogues
… OCS) measured on the UV1 beam line of the Astrid Synchrotron facility at the University of Aarhus in Denmark, are presented. Molecular synthesis (e.g. CO3, CO, H2CO3) induced by ion irradiated CO2/H 2O ices using facilities at Queens University Belfast are also reported. In particular this thesis …
-
Otimização de um protocolo de fixação e marcação para estudo do Rhodnius prolixus usando microtomografia síncrotron
During the years microtomography using synchrotron light technique has proved to be an excellent tool to study the internal and external structures of Rhodnius prolixus, main insect vector of Tripanossoma cruzi, and the etiologic agent of Chagas Disease. However, the first works have shown that the …
-
A comparative study of the existing methods for their suitability to beam stabilization in Storage Ring at Canadian Light Source
… (SR) is an important task in the 3rd generation synchrotron facility worldwide. Deviations in the position and angle of electron beam with respect to a desired orbit must be below 10% of the beam size. This requirement corresponds to about 3 μm deviations at the Canadian Light Source (CLS). …
-
High energy x-ray implementation of phase contrast and dark field imaging
… validated first through a pilot experiment at a synchrotron facility, then in a series of lab experiments. Results clearly indicate that implementations of phase contrast and dark field imaging at high x-ray energy exist, however particular care must be taken in the design and fabrication of the …
-
Measurement of equation of state of compressed hydrogen and deuterium
… (20 keV probe) at the Diamond Light Source synchrotron facility.</p>
-
Gamma-Ray Optical Studies of ⁷³Ge and ⁵⁷Fe
… derived for both a table-top x-ray system and a synchrotron radiation facility. For the table-top system, energy dispersive photon detectors were used to map the crystals in a computer-controlled goniometer system. At the synchrotron facility, the technique of x-ray topography was used to …
-
Substrate binding to MshB, a zinc-dependent deacetylase in the mycothiol biosynthetic pathway of Mycobacterium tuberculosis
… were grown and data were collected at the ESRF synchrotron facility. The crystal structure was solved by molecular replacement and most notably, glycerol and acetate (a product of the natural reaction) was found bound in the active site. This allowed a greater understanding regarding important …
-
Near-field Multi-slice Ptychography
… demonstrated with coherent hard X-rays at the synchrotron facility, achieving sub 100 nm lateral resolution, 300 µm depth resolution and extending the DoF to image samples exceeding 1 mm thickness. The validation of NMP in the hard X-ray regime paves the way for high-resolution large volume …
-
Micro- and macro-mechanical testing of grain boundary sliding in a Sn-Bi alloy
… with diffraction contrast tomography (DCT) at a synchrotron facility.</p> <p>The microcantilever tests enable grain boundary sliding and diffusion creep to be investigated separately by varying the normal and shear stresses on the grain boundary plane. GBS is dependent on grain boundary structure …
-
Advanced control systems for fast orbit feedback of synchrotron electron beams
Diamond Light Source is the UK’s national synchrotron facility that produces synchrotron radiation for research. At source points of synchrotron radiation, the electron beam stability relative to the beam size is critical for the optimal performance of synchrotrons. The current requirement at …
-
Investigations in molecular structure: from scattering to molecular complexes of brominated compounds
… of Strathclyde and also at the central synchrotron facility of Station 2.1 at the SRS Daresbury. Small angle X-ray scattering (SAXS) was carried out on solutions of methyl-4-hydroxybenzoate (pMHB) and 2-bromobenzoic acid. These studies were carried out after developing solution methods …
-
Development of diffraction enhanced computed tomography for imaging joints
… combined with computed tomography (CT) using a synchrotron radiation source. DEI is a modality that derives contrast from x-ray refraction, extinction (an extreme form of scatter rejection), and absorption (as in conventional radiography). The ability to add to an image’s contrast from the …
-
Fibroferrite: crystallographic, optical and synthesis experiments
… a rotating anode source and further studies at a synchrotron facility. None of the selected crystals was suitable for a single crystal X-ray diffraction study and the unit cell could not be found. Energy dispersive X-ray spectroscopy chemical analyses using a scanning electron microscope were …
-
The disordered- and ordered-state structures of κ-carrageenan : an X-ray scattering, molecular dynamics, and density-functional theory study : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Physics at Massey University, Palmerston North, New Zealand
… validated by comparison to data obtained at a synchrotron facility. The models will be further explored using density functional theory to calculate their expected optical rotation behaviour, which finds that the formation of double-helices from single chains is able to explain the increase in …
-
Tabletop imaging of antiferromagnetism with magneto-thermal microscopy
… antiferromagnetism rely on x-ray sources from a synchrotron facility, which limits the range of practical experiments. The focus of this dissertation is to develop magneto-thermal microscopy as a new tabletop technique for imaging antiferromagnets. We focus on materials in which the N\'eel order …
-
Investigations of catalyst and energy storage materials using 57Fe Mössbauer spectroscopy
… Mössbauer measurements of full cells at the ESRF synchrotron facility. Commercial materials were studied along with the effect of fabricating electrodes, and the charge state of electrodes, yielding useful information on their hyperfine structure. The studies herein, driven by industrial …
Page 1 of 2