Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 125 for “"Synchrotron light"”
-
A Synchrotron Light Fast Camera for EROS*
… to, and mis-steering in, the injection line. The synchrotron light fast camera works well; the resolution attained is near the theoretical limits calculated. While the resolution limits were not measured rigorously, tests with the camera indicated the 100 μm resolution requirement was achieved.
-
Ultra-low emittance lattice design for advanced synchrotron light sources
<p>Storage ring based synchrotron light sources deliver high brightness radiation generated by high quality electron beam. The electron beam emittance plays an importance role in controlling the brightness and coherence of the radiation output. An extensive design effort is required to optimse the …
-
Imaging dilute contrast materials in small animals using synchrotron light
… in the head of small animals, such as a rat, two synchrotron-based imaging methods were studied: K-Edge Subtraction (KES) imaging and Fluorescence Subtraction Imaging (FSI). KES needs wide monochromatic x-ray beams at two energies bracketing the K-edge of the contrast agent existing or injected in …
-
The absorption and reflection of linearly polarised synchrotron light by graphene and its interfaces
… have been characterised using synchrotron light at energies spanning the carbon 1s absorption edge. This method selects carbon bonds via the resonant excitation of atomic electrons of carbon into molecular orbitals. Polarisation-dependent reflection spectroscopy has been …
-
Development of a solid state amplifier for the 3rd harmonic cavity for ALBA synchrotron light source
In Synchrotron Light Source facilities with high energy and low emittance electron beams different techniques for improving the quality of the synchrotron light for the users are applied. With this aim ALBA, the Spanish 3rd generation Synchrotron Light Source, is developing a 3rd Harmonic …
-
Design of a Novel Readout ASIC for X-ray Diffraction Experiments at High-Energy Synchrotron Light Sources
… X-ray sources like the European Synchrotron Radiation Facility (ESRF). The requirements include a wide dynamic photon counting range up to 1 × 10^11 ph s^(−1) mm^(−2) with single photon sensitivity and a high versatility for many different measurement conditions. In addition, the …
-
X-ray imaging by partially coherent synchrotron light: Application to metallic alloys, tooth dentin and natural rock
Das harte Spektrum der BAMline am Berliner Synchrotron BESSY bietet die seltene Möglichkeit, Experimente mit hochauflösender Röntgenbildgebung und teil-kohärenter Strahlung zu machen. Diese Promotionsarbeit umfasst die Entwicklung eines neuen Tomographieaufbaus und dessen Anwendung auf drei …
-
Desenvolvimento de um método para definição de limites de posição e ângulo para o sistema de interlock de órbita do Sirius
… system whose purpose is to guarantee that the light beam generated by insertion devices of synchrotron light sources does not damage the vacuum chambers and other components present in the particle accelerator storage rings. Although some synchrotrons already have systems like this, there are …
-
Implementação da troca de emitâncias no booster do SIRIUS para melhoria da eficiência de injeção no anel de armazenamento
SIRIUS is the newest 4th generation synchrotron light source, built and operated by the Brazilian Synchrotron Light Laboratory (LNLS) at the Brazilian Center for Research in Energy and Materials (CNPEM). The injection system responsible for accumulating electrons in the storage ring comprises two …
-
Otimização de um protocolo de fixação e marcação para estudo do Rhodnius prolixus usando microtomografia síncrotron
During the years microtomography using synchrotron light technique has proved to be an excellent tool to study the internal and external structures of Rhodnius prolixus, main insect vector of Tripanossoma cruzi, and the etiologic agent of Chagas Disease. However, the first works have shown that the …
-
X -Ray and Pressure Measurements on Helium Solids
… data obtained from experiments at the National Synchrotron Light Source at the Brookhaven National Laboratory are also presented here. The vacancy formation energy of fcc 4He at 10.4 cm3 /mol was obtained by two different methods. In addition, c/a ratios were determined to be ideal for hcp 4He …
-
Energy Recovery Linear Accelerator Lattice Design and Coherent Synchrotron Radiation
… potential drivers for novel fourth-generation synchrotron light sources. An ERL combines the high quality beams of a linear accelerator with the high currents possible in a storage ring. The excessive power needs of a lone linac are avoided by circulating accelerated particles back through the …
-
Electron beam sizes and lifetimes at MAX II and MAX III
The MAX II and MAX III synchrotron light sources at MAX-lab provide synchrotron radiation for experiments in a wide variety of research fields. The synchrotron radiation is emitted by ultra-relativistic electrons circulating in electron storage rings. In this thesis the transverse and longitudinal …
-
Synchrotron infrared spectroscopy of domain walls and high pressure phases of multiferroics
<p>Synchrotron light sources provide high throughput, broadband infrared light enabling the development of novel techniques, inaccessible using traditional sources. High pressure techniques benefit greatly, as significant signal loss occurs from focusing the light through diamonds into a small …
-
PROBING BAND MAGNETISM IN DIFFERENT DIMENSIONS: ENERGY, SPIN AND TIME-RESOLVED STUDIES
… HHG at NFFA-SPRINT laboratory) and soft X-ray synchrotron light (at Elettra, Diamond and ESRF synchrotron light sources). I used photoemission as the main tool in my investigation, supplementing my results with absorption spectroscopy. I focused on three materials, Fe(001)-p(1x1)O/MgO(001), …
-
Advancing X-ray Multi-Projection Imaging : Towards Four-Dimensional Reconstruction and Analysis of Rapid Flows
Fourth-generation synchrotron light sources deliver flux densities up to two orders of magnitude higher than previous generations, enabling X-ray imaging at unprecedented spatiotemporal resolution. This is attractive for non-destructive 4D (3D + time) studies of fast dynamics under in-situ or …
-
The controlled drift detector as an x-ray imaging device for diffraction enhanced imaging
… of DEI data taken with the CDD in the ELETTRA synchrotron light source facility in Trieste (Italy) in 2005, is presented and the applicability of both this new technique and the novel detector are discussed.
Page 1 of 7