Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 16 of 16 for “"Synthetic diagnostic"”
-
Validation of ion and electron scale gyrokinetic simulations in an NSTX H-mode and comparisons with a synthetic diagnostic for high-k scattering
In this thesis I perform an extensive validation study in an NSTX NBI-heated H-mode discharge, predicting that electron thermal transport can be entirely explained by shortwavelength electron-scale turbulence fluctuations driven by the electron temperature gradient mode (ETG), both in conditions of …
-
Indirectly Driven High Yield Implosions and Phase Contrast Imaging the N+1 Shock
… shaping errors of a NIF-like laser system. A synthetic diagnostic code (GREENER) is also presented, it was written to simulate X-ray phase contrast imaging (XPCI), a particularly useful diagnostic for examining shocks and interfaces. The synthetic diagnostic code was developed within the …
-
An experimental and computational study of tokamak plasma turbulence
… of the Tangential Phase Contrast Imaging (TPCI) diagnostic that measures electron density fluctuations. On the experimental side of this work, the TPCI diagnostic is upgraded with new equipment to perform ion scale measurements. The diagnostic is used in an initial study of turbulence when the …
-
The ITER electron cyclotron emission diagnostic : conventional and advanced techniques for assessment, operation, and neoclassical tearing mode control
… by an electron cyclotron emission (ECE) diagnostic, which will also provide the primary measurement of electron temperature profiles. This dissertation discusses the design and assessment of the ITER ECE diagnostic. Development of the ECE diagnostic for ITER poses additional physical …
-
Experimental analysis of suprathermal electrons generated by electron cyclotron waves in tokamak plasmas
… Plasma Center at EPFL, Switzerland. A hard X-ray diagnostic, which measures the bremsstrahlung radiation of the suprathermal electrons in radial and energy spaces, has been mainly used for the analysis, and the measurement has been compared to an estimation made by Fokker-Planck modeling coupled …
-
A study of reversed shear Alfvén eigenmodes in Alcator C-Mod with phase contrast imaging
… phase contrast imaging, and interpreted with a synthetic diagnostic using numerical results from the ideal MHD code NOVA, provides constraints on the evolution of qmi,. Additional observations including mode coupling, mode tunneling, and minimum frequency scaling are discussed in light of …
-
Experimental measurements and numerical modeling of fast-ion distributions in the Alcator C-Mod Tokamak
… bounce-averaged Fokker-Planck code CQL3D. A new synthetic diagnostic integrated into CQL3D is used to make direct comparisons with the CNPA. We find that for plasmas that have a steady-state fast-ion distribution (df /dt = 0) the simulation and the experiment have good agreement. However, in …
-
Turbulence and transport measurements in Alcator C-Mod and comparisons with Gyrokinetic simulations
… monitored using a phase contrast imaging (PCI) diagnostic, an absolutely calibrated diagnostic that measures the line-integral of the electron density fluctuations along 32 vertical chords. In these experiments the seeding reduced the PCI density fluctuations, and had a stabilizing effect on the …
-
Subcritical turbulence in the Mega Ampere Spherical Tokamak
… ion-scale density fluctuations from the MAST BES diagnostic. We apply a synthetic diagnostic to our simulation data and find reasonable agreement of the correlation properties of the simulated and experimental turbulence, most notably of the correlation time, for which significant discrepancies …
-
Generative AI for Digital Pathology: Advancing Diffusion, Vision-Language, and Safety-Aware Models
… decision-making processes to generating synthetic diagnostic text for enhancing vision-language model (VLM) representation and alignment. The work further explores the integration of safety and context awareness into generative frameworks to significantly improve model performance and …
-
Modelling of Lower Hybrid Current Drive in the Tore Supra Tokamak
… the current profile, LH power deposition, and a synthetic diagnostic for the FEB emission of the LH accelerated electrons in the energy range 50 110 keV. The reconstructed emission can be directly compared to FEB measurement from hard x-ray (HXR) detection system. A study of fully non-inductive …
-
Investigation of the interplay between Electron-Cyclotron waves, suprathermal electrons and turbulence in tokamak plasmas
… forward modeling of a discharge thanks to the synthetic diagnostic embedded in the quasilinear bounce-average drift-kinetic Fokker-Planck solver LUKE. It is shown, by analyzing experimental data, that the radial transport of fast electrons increases with the injected wave power. This is further …
-
Tentative First Observations of Quasi-Stationary Zonal Flows in a Spherical Tokamak & Improvements in Image-Velocimetry Workflows
… this end, the Beam Emission Spectroscopy (BES) diagnostic on the upgraded Mega-Ampere Spherical Tokamak (MAST-Upgrade) was utilised. Image-velocimetry techniques, which are used to infer velocity fields from imag- ing diagnostics such as BES, were extensively performance tested for the first …
-
Advanced numerical modelling of transport in tokamak plasma and confrontation to experiments
… développements proposés incluent la création de diagnostics synthétiques de bolomètrie et caméra visible. Les comparaisons avec l'expérience ont révélé des faiblesses dans les modèles physiques initiaux, traitées au cours de cette thèse. Parmi les améliorations, on note une meilleure cohérence du …
-
Développement d’un diagnostic de diffusion Thomson Haute Résolution pour le contrôle temps réel de l’extraction de particules et de puissance à partir des profils cinétiques de bords
… refroidis. Pour caractériser ces plasmas, divers diagnostics sont utilisés, mais des limitations subsistent, notamment pour mesurer certaines régions spécifiques du plasma.Pour surmonter ces limitations, un nouveau diagnostic de diffusion Thomson est en cours d'installation sur WEST. Ce système, …