Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 55 for “"Synthetic urine"”.

  1. EFFECT OF URINARY MACROMOLECULES ON CRYSTALLIZATION OF CALCIUM-OXALATE IN SYNTHETIC URINE SOLUTIONS

    … on the crystallization of calcium oxalate from a synthetic urine-like solution was studied in a mixed suspension-mixed product removal (MSMPR) continuous crystallizer. Precipitation of calcium oxalate crystals occurs during the continuous passage of urine through the renal system (kidney, bladder …

    arizona-thes Repository record for EFFECT OF URINARY MACROMOLECULES ON CRYSTALLIZATION OF CALCIUM-OXALATE IN SYNTHETIC URINE SOLUTIONS (opens in a new tab)

  2. The Potential of Iron Electrodes in Electrochemical Cells for the Stabilization of Synthetic Urine

    Source separation and urine treatment present the opportunity to significantly reduce influent concentrations of nitrogen and phosphorus in wastewater treatment plants and to capture those minerals for reuse. This study aims to use electrochemical cells with a sacrificial iron electrode to produce …

    clemson Repository record for The Potential of Iron Electrodes in Electrochemical Cells for the Stabilization of Synthetic Urine (opens in a new tab)

  3. Comparison of Functional Porous Organic Polymers (POPs) and Natural Material Zeolite for Nitrogen Removal and Recovery from Synthetic Urine

    Urine comprises around 1% of domestic sewage volume but holds 80% of total nitrogen. Source separation is a sustainable way to wastewater management than traditional way due to low energy cost and preventing certain pollutants into wastewater treatment plants. Currently, removing and recovering …

    usf Repository record for Comparison of Functional Porous Organic Polymers (POPs) and Natural Material Zeolite for Nitrogen Removal and Recovery from Synthetic Urine (opens in a new tab)

  4. Detecting fentanyl, norfentanyl, and fentanyl analog metabolites in synthetic urine using biocompatible-solid phase microextraction and direct analysis in real time-mass spectrometry

    … Spectrometry (DART®-MS). Given the increase of synthetic opioid-overdose deaths in the past several years, the development and use of rapid analytical techniques is necessary for crime laboratories and medical examiner offices to consider implementing. This project involved the optimization of …

    bu Repository record for Detecting fentanyl, norfentanyl, and fentanyl analog metabolites in synthetic urine using biocompatible-solid phase microextraction and direct analysis in real time-mass spectrometry (opens in a new tab)

  5. High throughput quantitative analysis of four commonly encountered drug metabolites in synthetic urine via biocompatible-solid phase microextraction and direct analysis in real time-mass spectrometry

    … identify, and quantitate drugs of abuse in urine samples. When these methods are combined, the entire analytical process, from start to finish, can be completed manually in just over 2 minutes per sample. By increasing sample throughput and decreasing human labor, toxicology labs would …

    bu Repository record for High throughput quantitative analysis of four commonly encountered drug metabolites in synthetic urine via biocompatible-solid phase microextraction and direct analysis in real time-mass spectrometry (opens in a new tab)

  6. Comparison of Liquid-Liquid Extraction and Solid Phase Extraction of Mephedrone

    … was a difference and which was more efficient. Synthetic urine samples were spiked with mephedrone, extracted using both methods, and analyzed with GC-MS. Spiked synthetic urine samples were also analyzed to determine the limit of detection for mephedrone. A T-ratio test determined that there is …

    usm Repository record for Comparison of Liquid-Liquid Extraction and Solid Phase Extraction of Mephedrone (opens in a new tab)

  7. Investigation of Trace Uranium in Biological Matrices

    A system for the analysis of urine bioassay samples for the purpose of inversely investigating an unknown exposure to uranium has been developed. This technique involves the use of a thin flow electrochemical cell in conjunction with an anodized glassy carbon electrode to selectively separate …

    tamu Repository record for Investigation of Trace Uranium in Biological Matrices (opens in a new tab)

  8. Evaluation of the progressive freeze concentration process for water recovery and nutrient concentration

    … reverse osmosis (RO) brine concentrate, and synthetic urine. In this study, a one-factor-at-a-time approach was used to investigate the impact of eight process parameters on salt percent removal, ice percent recovery, and the effective partition constant (K). Based on the regression analysis, …

    iastate Repository record for Evaluation of the progressive freeze concentration process for water recovery and nutrient concentration (opens in a new tab)

  9. Determination of the Role of Glucose and pH in the Production of Biofilms, Phospholipase and Protease in Candida auris

    … high-risk group. The study investigated whether synthetic urine mimicking the high glucose and low pH conditions found in diabetic urine would increase the production of biofilms, protease and phospholipase of an aggregating (NCPF 8977) and non-aggregating strain (NCPF 8971) of C. auris. C. auris …

    cent-lancashire Download file for Determination of the Role of Glucose and pH in the Production of Biofilms, Phospholipase and Protease in Candida auris (opens in a new tab)

  10. J- and H-Aggregates of Cyanine Dyes for Dopamine Detection.

    … then use these nanoparticles to detect DA in a synthetic urine medium. Second, we demonstrate lithocholic acid (LCA) and DiSC2(5) coassembly at the equimolar ratio in ammonia solution into J-aggregate nanotubes. By integrating the J-aggregate nanotubes into transparent agarose hydrogel film, we …

    ucf Repository record for J- and H-Aggregates of Cyanine Dyes for Dopamine Detection. (opens in a new tab)

  11. Potential adulterating capabilities of commercial zinc products on preliminary immunoassay screenings for the detection of ethyl glucuronide (ETG)

    … (2, 3). False negatives have been reported from urine testing of drugs such as cocaine, methamphetamine, opiates, and cannabinoids. Nevertheless, minimal research has been conducted concerning zinc’s effect on the adulteration of alcohol metabolite testing. Ethyl glucuronide (EtG) is a promising …

    bu Repository record for Potential adulterating capabilities of commercial zinc products on preliminary immunoassay screenings for the detection of ethyl glucuronide (ETG) (opens in a new tab)

  12. Intensification of Micro-Plasma Bubble Processing for N-Fixation and its Potential Application

    … opportunities; (4) air plasma processing in urea/synthetic urine solutions for ammonia recovery as well as synergy of plasma-enzyme catalysis; (5) mini-review of potential plasma treatment that could be applied in human space exploration. Firstly, air plasma is much superior to nitrogen plasma for …

    adelaide Repository record for Intensification of Micro-Plasma Bubble Processing for N-Fixation and its Potential Application (opens in a new tab)

  13. Dual-Energy Computed Tomography Scan and Color Doppler Twinkling Artifact of Canine Uroliths to Determine Urolith Fragility by Laser Lithotripsy.

    … study were to 1) Determine whether uroliths in a synthetic urine bath will have a large increase in their overall weight. 2a) Determine whether Dual energy CT measurements including dual energy number and the dual energy ratio correlates with urolith fragility by laser lithotripsy. 2b) Determine …

    guelph Repository record for Dual-Energy Computed Tomography Scan and Color Doppler Twinkling Artifact of Canine Uroliths to Determine Urolith Fragility by Laser Lithotripsy. (opens in a new tab)

  14. The Development and Evaluation of Methods for the Screening of Steroids using Molecular Imprinted Polymers coupled with comprehensive Gas Chromatography/Mass Spectrometry and Aptamers coupled with Liquid Chromatography/Mass Spectrometry

    … detection of steroids is usually undertaken in urine and these analyses present many challenges. Issues related to the complexity of the matrix, the separation of exogenous from endogenous species and the very low detection limits have placed increasing demands on clinical and International …

    the-open-u Download PDF for The Development and Evaluation of Methods for the Screening of Steroids using Molecular Imprinted Polymers coupled with comprehensive Gas Chromatography/Mass Spectrometry and Aptamers coupled with Liquid Chromatography/Mass Spectrometry (opens in a new tab)

  15. The Development of M3+-Doped Mesoporous Ti4O7 Electrode for Pharmaceutical Degradation in Fresh Human Urine

    … and pharmaceutical degradation rate in a full synthetic urine matrix with four common pharmaceuticals. Our results show that the Cobalt (Co3+) doped-mesoporous Ti4O7 electrodes have a 30 hours lifetime and were able to degrade 96.7% sulfamethoxazole (SMX) within 60 minutes. In conclusion, the …

    washington Repository record for The Development of M3+-Doped Mesoporous Ti4O7 Electrode for Pharmaceutical Degradation in Fresh Human Urine (opens in a new tab)

  16. Developing Salicylate-Selective Polymer Membrane Electrodes Based on Lutetium (Iii) Porphyrins

    … metalloporphyrin-based ISEs were placed in a synthetic urine medium to analyze salicylate levels of clinical interest, where these ion-selective electrodes continued to exhibit excellent selectivity toward salicylate. Finally, the electrode results were then compared with the Trinder method of …

    mo-state Repository record for Developing Salicylate-Selective Polymer Membrane Electrodes Based on Lutetium (Iii) Porphyrins (opens in a new tab)

  17. A metabolomics analysis and the development of a fluorescent assay for kynurenine for the diagnosis of sepsis in trauma patients

    … to quantify the amount of kynurenine in a urine sample. The standard addition technique was chosen as it removes matrix affects which would be present when using biological samples. Tests performed on pure samples of kynurenine, gave results within 5 % of the actual concentration. Synthetic …

    birmingham Download PDF for A metabolomics analysis and the development of a fluorescent assay for kynurenine for the diagnosis of sepsis in trauma patients (opens in a new tab)

  18. Turn-On Fluorescence of H-Aggregate Nanoparticles for Selective Protein Detection

    … a small amount of serum albumin may leak into urine from blood if there is damage to kidneys. Therefore, the detection of urine albumin has become a non-invasive method for screening kidney disease. Cyanine dyes are a fluorescent compound, which are used in biotechnology such as membrane …

    ucf Repository record for Turn-On Fluorescence of H-Aggregate Nanoparticles for Selective Protein Detection (opens in a new tab)

  19. ENABLING RAPID DIAGNOSTICS FROM LARGE-VOLUME COMPLEX SAMPLES WITH AUTOMATED BIOMARKER ENRICHMENT STRATEGIES

    … fragmented Borrelia burgdorferi genomic DNA in synthetic urine. Third, the Auto-MATICS is adapted for bloodstream infection workflows by pairing it with Fc-containing mannose binding lectin (FcMBL)-functionalized magnetic beads to capture and enrich low-concentration bacteria from 8 mL whole …

    maryland Repository record for ENABLING RAPID DIAGNOSTICS FROM LARGE-VOLUME COMPLEX SAMPLES WITH AUTOMATED BIOMARKER ENRICHMENT STRATEGIES (opens in a new tab)

  20. Removing Pharmaceuticals and Personal Care Products from Urine with Waterless Urinal Sealants

    … domestic sewage, which are excreted via human urine and feces. Therefore, this dissertation focused on removing PPCPs from the urine using waterless urinal sealant fluids.At first, I investigated the potential for waterless urinal sealant fluids to remove pharmaceuticals from urine. 1H-NMR, …

    unr Repository record for Removing Pharmaceuticals and Personal Care Products from Urine with Waterless Urinal Sealants (opens in a new tab)

Page 1 of 3