Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"System resolution"”.
-
Matrizes, Sistemas Lineares e Fatoração LU
… deals with the concepts and results on linear systems, including matrix and vectors theory of R n as the basis for a good understanding of the approaches. In order to deal with the question LU, we consider the results, mainly, in the case of operations between matrices, between vectors, their …
-
Advancing Total Body Photography for Early Detection and Spatio-temporal Monitoring of Skin Cancer
… applications at the bedside, including limited system resolution, limited image sharpness, lack of robust longitudinal tracking methods, and absence of a standardized data format. The first part of the dissertation introduces a 3D-vision-based method to improve TBP image fidelity in terms of …
-
FROM ART TO PART: A SIMULTANEOUS GEOMETRY AND DECORATION WORKFLOW
… and match the reproduction ink jet printing system resolution and specification. Developed software automatically calculates the dot pattern to reproduce the art work onto the correct prototyped surface location.</p>
-
Opposition effect experimentation and a theoretical investigation involving cylinders
… effect are investigated using an optical system of greater resolution than has been used in previously reported studies. . The samples studied, many previously unexamined, include some organic materials. Even with improved system resolution, opposition effect peaks produced by some samples …
-
SMALL SATELLITE SWARM THEORY FOR SPARSE APERTURE RADAR APPLICATIONS
In the next few years, the Space Systems Academic Group (SSAG) and the Small Satellite Laboratory at the Naval Postgraduate School (NPS) may begin work on a small satellite swarm constellation. This thesis introduces flight operations concepts for small satellite formations conducting sparse …
-
Measurement of strain in large structures using the modal power distribution of embedded graded index optical fibre sensors
… compressional and extensional axial strains. The system resolution is estimated to be 100 microstrain and the range is unlimited (measurements were made up to a maximum of 2000 microstrain).
-
Quadrature Radar Demodulation Techniques for Accurate Displacement Detection
Microwave Doppler radar systems can be used to measure human vital signs by tracking torso displacement. Technical requirements for such systems depend on detection object and objective, resolution and sensitivity, as well as practical constraints such as cost, size and power consumption. Due to …
-
Coded Aperture Magnetic Sector Mass Spectrometry
… requires the need for portable or hand-held systems for use in field work or harsh environments. While only requiring “sufficient” mass resolution to meet the needs of their application space, these miniaturized systems suffer from poor signal to background ratio which limits their …
-
Hybrid Reference Datasets for Quantitative Computed Tomography Characterization and Conformance
… clinical advantages in providing high spatial resolution and fast imaging time. Although limited, the high resolution of CT imaging enables small objects such as lesions to be realized with good detail. Partly due to their size and the fact that CT is noise and resolution limited, the effects …
-
A Feature Interaction Resolution Scheme Based on Controlled Phenomena
Systems that are assembled from independently developed features suffer from feature interactions, in which features affect one another's behaviour in surprising ways. To ensure that a system behaves as intended, developers need to analyze all potential interactions -- and many of the identified …
-
The laser mirror alignment system for the LHCb RICH detectors
… mrad so as not to degrade the inherent 0.7 mrad resolution of the detector. As the mirrors move out of alignment over time, the performance of the RICH will deteriorate, unless corrected. This thesis describes the design and characterisation of the Laser Mirror Alignment Monitoring System and its …
-
TIME-OF-FLIGHT AND ENERGY LOSS ANALYSIS ON THE UNM FISSION FRAGMENT SPECTROMETER
… of the spectrometer towards improving the resolution of the system. Different thicknesses of TOF conversion foils were examined with alpha particles and fission fragments: 20, 55, and 100 µg/cm2 carbon foils. For the thinnest carbon foil studied, a timing resolution of 160 ps FWHM over 32 …
-
Development of a Grond-Based High-Resolution 3D-SAR System for Studying the Microwave Scattering Characteristics of Trees
This thesis presents the development of a high-resolution ground-based 3D-SAR system and investigates its application to microwave-vegetation studies. The development process of the system is detailed including an enumeration of high-level requirements, discussions on key design issues, and …
-
A technique for astronomical spectroscopy with a multi-aperture telescope
… A discussion relating to data obtained using the system in single fibre mode and to RPCS data obtained at intermediate resolution is presented in chapters six and seven respectively. The former permitted a preliminary determination to be made of both system resolution and the approximate …
-
Computational Imaging Methods for Analysis of DaTScan SPECT Images
… is challenging due to the limited spatial resolution and high image noise in SPECT images and the physiological variability in these regions. To address this issue, we propose a three-dimensional physics-guided estimation-based method for segmenting SPECT images. The method implicitly …
-
Through-the-Wall Imaging and Multipath Exploitation
… and compute the Cramer-Rao bound to obtain the system resolution. We conduct experiments on a simple array platform to support our theoretical approach.
-
Development of high-speed fibre-optical laser scanning system for defect recogntion
High-speed fibre-optic laser scanning systems are being used in automated industrial manufacturing environments to determine surface defects. Recent methods of surface defect detection involve the use of fibre-optic light emitting and detection assemblies. This thesis deals with the design and …
-
Study of two-photon Line Excitation Array Detection microscopy
… 1 kHz volumetric scan rates with sub-cellular resolution, as action potentials propagate on sub-millisecond time scales. Monitoring these signals requires in vivo experimentation, so additional care must be taken to avoid invasive methods that may damage sample tissue to live animal subjects. …
-
Stress in ion-beam assisted silicon dioxide and tantalum pentoxide thin films
… Influence of deposition conditions (deposition system geometry, nature and amount of gas in the chamber, substrate cleaning and ion-assistance parameters) on films properties (stress, composition, refractive index njoonm and extinction coefficient ksoonm) was investigated.A scanning method, …
-
Advances in Gamma-Ray Imaging with Intensified Quantum-Imaging Detectors
… camera, iQID demonstrated ultra-high spatial resolution (<100 micron) and many other advantages over traditional gamma cameras. This work focuses on advancing this conceptually-proven gamma-ray imaging technology to make it ready for both preclinical and clinical applications. To start with, a …
Page 1 of 3