Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 32 for “"T-Stub"”

  1. Mathematical Modeling of Behavior of T-Stub Connections

    … with minimal loss of strength or stiffness. A T-stub connection, which can be designed to resist high moments expected in multi-story steel building frames, is becoming a popular alternative to WMC. This study reports the findings of an investigation conducted to mathematically describe the …

    ohiolink Repository record for Mathematical Modeling of Behavior of T-Stub Connections (opens in a new tab)

  2. Large deformation of T-stub connection in bolted steel joints

    … which are represented by an equivalent T-stub. Understanding how large deformation develops in T-stubs is, therefore, needed to characterise the joint performance. However, the Eurocodes only provide guidance on how to determine the moment resistance of a joint and no information were …

    ucl Repository record for Large deformation of T-stub connection in bolted steel joints (opens in a new tab)

  3. Assessment of the behaviour of T-stub joint under impact loading

    … a estabelecer a resposta não linear de T-stubs. Os modelos são validados com resultados de ensaios experimentais desenvolvidos no âmbito do projecto de investigação “ImpactFIRE”, desenvolvido na Universidade de Coimbra. São considerados T-stubs soldados chapas de espessura de 10 e 15 mm em …

    coimbro Repository record for Assessment of the behaviour of T-stub joint under impact loading (opens in a new tab)

  4. Improvement of the mechanical model for mode 1 T-stub plastic strength

    … The component studied in this thesis is the T-stub. First, the state-of-the-art is reviewed. A detailed presentation of this component is given. The same applies to various characterisation models. These range from the current standards, which is conservative and easy to apply, to the most …

    liege Repository record for Improvement of the mechanical model for mode 1 T-stub plastic strength (opens in a new tab)

  5. Behavior Of Thick Flange Built-up T-stub Connections For Moment Resisting Frames

    … this research is to widen the applicability of T-stub connections by investigating the behavior of thick-flange built-up T-stubs needed for deep beams which meet the prequalification requirements for moment-resisting-frames (MRF). Oftentimes the heavy rolled profiles needed to fabricate the T-stub …

    ohiolink Repository record for Behavior Of Thick Flange Built-up T-stub Connections For Moment Resisting Frames (opens in a new tab)

  6. Prequalification and Design of Rolled Bolted T-stub Connections in Moment Resisting Frames

    … costs have led to the development of bolted T-stub connections as a financially viable option. Brittle failures of what was, at the time, considered an acceptable FR connection forced the American Institute of Steel Construction (AISC) to require pre-testing of all moment connections used in …

    ohiolink Repository record for Prequalification and Design of Rolled Bolted T-stub Connections in Moment Resisting Frames (opens in a new tab)

  7. Evaluation of a Multi-linear Stiffness Model for T-Stub Connection Under Varying Fastener Pretension Levels

    … determining important stiffness parameters of T-Stub Bolted Connection under varying pretension levels in fasteners. The parameters obtained through regression analysis as part of the research enables the Swanson’s Mathematical model to predict P - Δ curve more accurately.

    ohiolink Repository record for Evaluation of a Multi-linear Stiffness Model for T-Stub Connection Under Varying Fastener Pretension Levels (opens in a new tab)

  8. Response of Flush End-Plate Joints under Combined Actions

    … of a basic component of the connection: the T-stub. Research works carried out in the recent past extensively investigated the T-stub response under tension, while no data are available for the T-stub's response under combined tension (N) and shear force (V). In the thesis experimental, …

    trento Repository record for Response of Flush End-Plate Joints under Combined Actions (opens in a new tab)

  9. Ανάπτυξη των γραμμών διαρροής σε εφελκυόμενες κοχλιωτές συνδέσεις αλουμινίου. Αριθμητική και πειραματική προσέγγιση

    … of aluminium connections by means of the T-stub idealization is imperative as long as it represents an efficient modeling tool for the resistance of the components of bolted joints. In the present work, both a numerical simulation and an experimental analysis program concerning the …

    greece Repository record for Ανάπτυξη των γραμμών διαρροής σε εφελκυόμενες κοχλιωτές συνδέσεις αλουμινίου. Αριθμητική και πειραματική προσέγγιση (opens in a new tab)

  10. MODELING OF SLIP AND BEARING INTERACTIONS IN BOLTED CONNECTIONS SUBJECTED TO CYCLIC LOADING

    … of the combined slip and bearing mechanisms in T-Stub connections or bolted connections of similar geometry. A monotonic, multi-linear response is presented which accounts for variable initial bolt locations. A cyclic model is developed based upon the monotonic response and predetermined loading …

    ohiolink Repository record for MODELING OF SLIP AND BEARING INTERACTIONS IN BOLTED CONNECTIONS SUBJECTED TO CYCLIC LOADING (opens in a new tab)

  11. Assessment of risk of disproportionate collapse of steel building structures exposed to multiple hazards

    … were considered. A macro-model for a bolted T-stub connections was developed by considering the behavior of each connection element individually (i.e. T-stub, shear tab and panel zone) and assembling the elements to form a complete connection model, which was subsequently calibrated to …

    gatech Repository record for Assessment of risk of disproportionate collapse of steel building structures exposed to multiple hazards (opens in a new tab)

  12. Performance Prediction and Evaluation of Low Ductility Steel Moment Frames for Seismic Loads

    … to 120 feet tall. All of the buildings with T-stub connections performed well except for the 3-story building in SDC D which exceeded the permanent residual drift limit. As was seen from the measured moment-rotation behavior of the connection, the end-plate connection behaves very similar to …

    uiuc Repository record for Performance Prediction and Evaluation of Low Ductility Steel Moment Frames for Seismic Loads (opens in a new tab)

  13. A Model for Prediction of Fracture Initiation in Finite Element Analysis of Bolted Steel Connections

    … the procedure. These included two bolted T-stub connections and two top-and-seat angle connections. Load-displacement curves for the full scale models were found to coincide with experimental results.

    ohiolink Repository record for A Model for Prediction of Fracture Initiation in Finite Element Analysis of Bolted Steel Connections (opens in a new tab)

  14. Conexiones Viga-Columna de Momento Utilizando Perfiles T Soldados

    … de momento precalificada por FEMA, T-Stub, la que corresponde a dos perfiles T dispuestos de forma apernada en la unión. Se estima que su uso agiliza el proceso constructivo ya que estás piezas pueden ser fabricadas en serie en maestranzas y sólo son apernadas en terreno. El objetivo …

    chile Repository record for Conexiones Viga-Columna de Momento Utilizando Perfiles T Soldados (opens in a new tab)

  15. Desempeño sísmico de edificio de acero con conexiones apernadas doble T

    … en FEMA-350, donde se precalifica la conexión t-stub plegada para ser usada como SMF solo hasta perfiles tamaño W24.

    chile Repository record for Desempeño sísmico de edificio de acero con conexiones apernadas doble T (opens in a new tab)

Page 1 of 2