Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 306 for “"TDR"”.

  1. Impulse TDR and its Application to Characterisation of Antennas

    … using a step-function time domain reflectometer (TDR) along with frequency-domain processing techniques. Localisation of the measurement in time prior to transformation allows for the dismissal of unwanted spurious reflections, eliminating the need for an anechoic chamber. An alternative technique …

    waikato-masters Repository record for Impulse TDR and its Application to Characterisation of Antennas (opens in a new tab) Download file for Impulse TDR and its Application to Characterisation of Antennas (opens in a new tab)

  2. Accuracy and Bias of TDR Measurements in Compacted Sands

    … parameters. Time domain reflectometry (TDR) is one such method. Relying on the propagation of an electromagnetic wave through the soil sample, TDR can be used to measure both in-situ moisture content as well as soil dry density. Although TDR is relatively new to the field of geotechnical …

    usf Repository record for Accuracy and Bias of TDR Measurements in Compacted Sands (opens in a new tab)

  3. Design of a Multilevel - TDR Probe for Measuring Soil Water Content

    ABSTRACT The TDR measures soil water content by measuring the travel time of an electromagnetic step pulse through a wave guide embedded in the soil. Damage during insertion and retrieval of the probe makes it unsuitable for repeated use. A multilevel-TDR probe with adequate protection for cable …

    manitoba Repository record for Design of a Multilevel - TDR Probe for Measuring Soil Water Content (opens in a new tab)

  4. Time domain reflectometry (TDR) techniques for the design of distributed sensors

    … system consists of time domain reflectometry (TDR) signal processing equipment and specially designed sensing cables. The TDR equipment sends a high-frequency electric pulse (in the gigahertz range) along the sensing cable. Any change in electric impedance along the cable reflects some portion …

    vt Repository record for Time domain reflectometry (TDR) techniques for the design of distributed sensors (opens in a new tab)

  5. A Study on the Calibration and Accuracy of the One-Step TDR Method

    … parameters. Time domain reflectometry (TDR) is one such method. Several advances have been made over the past few years to further the use of TDR technology in water content and density measurement of compacted fill. The one-step method relies on the measurement of the apparent …

    usf Repository record for A Study on the Calibration and Accuracy of the One-Step TDR Method (opens in a new tab)

  6. Numerical methods in soil hydrology: TDR waveform analysis and water vapor diode simulation

    … water content from time domain reflectometry (TDR) measurements and simulate soil water accumulation in selected soil layers. TDR enables nondestructive and continuous soil water content measurements. Traditional TDR waveguides have relatively long probes (>150 mm), but new TDR waveguides tend …

    iastate Repository record for Numerical methods in soil hydrology: TDR waveform analysis and water vapor diode simulation (opens in a new tab)

  7. Application of e-TDR to achieve precise time synchronization and controlled asynchronization of remotely located signals

    Time Domain Reflectometer (TDR) measures the electrical length of a cable from the applied end to the location of an impedance change. An impedance change causes a portion of the applied signal to reflect back based on the value of its reflection coefficient. The time of flight (TOF) between the …

    texas Repository record for Application of e-TDR to achieve precise time synchronization and controlled asynchronization of remotely located signals (opens in a new tab)

  8. Time Domain Reflectometry Measurement of Water Content and Electrical Conductivity Using a Polyolefin Coated TDR Probe

    The use of time domain reflectometry (TDR) to determine water content (θv) from the measurement of the apparent dielectric constant (Ka) or the square root of the apparent dielectric constant (Ka 0.5) in highly saline environments has been limited due to the dampening effect that electrical …

    waterloo Repository record for Time Domain Reflectometry Measurement of Water Content and Electrical Conductivity Using a Polyolefin Coated TDR Probe (opens in a new tab)

  9. Thermo-TDR measurements of thermal properties and volume fractions of water, solids, and air in soil

    A thermo-TDR probe is a new device that allows rapid and accurate determination of soil thermal and electrical properties. The thermo-TDR was used to examine the relationships between thermal properties and the volume fractions of soil water ([Theta]), solids (v[Subfield s]), and air (n[Subfield …

    iastate Repository record for Thermo-TDR measurements of thermal properties and volume fractions of water, solids, and air in soil (opens in a new tab)

  10. Using rainfall simulation, TDR, and tracer anions to determine effects of soil properties on nitrate leaching

    … of non-destructive time domain reflectometry (TDR) techniques. A laboratory experiment was conducted to study the effects of different soil bulk density (1.10, 1.33, 1.57, and 1.81 g/cm 3) in the zone of N application and antecedent soil moisture by mass (10 and 15%) on NO3-N leaching during …

    iastate Repository record for Using rainfall simulation, TDR, and tracer anions to determine effects of soil properties on nitrate leaching (opens in a new tab)

  11. Concordância entre procedimentos de triagem auditiva e o teste de dígitos no ruído (TDR) em estudantes

    Introduction: Identifying hearing loss in students is essential to ensure adequate educational and social development. Objective: To assess the agreement between auditory screening procedures and the Hearing-in-Noise Test (HINT) adapted as the Digits-in-Noise Test (DIN) in students. Method: This …

    brazil-ufrn Repository record for Concordância entre procedimentos de triagem auditiva e o teste de dígitos no ruído (TDR) em estudantes (opens in a new tab) Embargoed until 2028-02-02

  12. Is TDR in Virginia DOA? A Study of the State of Transfer of Development Rights Programs in Virginia

    … regarding obstacles and limitations to TDR program development and implementation, from every locality in the Commonwealth authorized to employ this tool. Based on findings of pertinent TDR literature, this research outlines the environment in which policy in Virginia is being developed …

    vcu Repository record for Is TDR in Virginia DOA? A Study of the State of Transfer of Development Rights Programs in Virginia (opens in a new tab)

  13. Análise de falhas dos cabos utilizados nas redes metálicas em telecomunicações com as técnicas de Time Domain Reflectometry (TDR)

    … no domínio do tempo do espectro de dispersão (SSTDR) e a reflectometria no domínio do tempo de sequência (STDR). São analisados os sinais comumente presentes nos cabos telefônicos, com o objetivo de localizar falhas intermitentes. Essa análise se faz necessária porque a linha telefônica, …

    brazil-ufrgs Repository record for Análise de falhas dos cabos utilizados nas redes metálicas em telecomunicações com as técnicas de Time Domain Reflectometry (TDR) (opens in a new tab)

  14. Transferable development rights : a policy analysis of a planning instrument and its application in Vancouver

    … known as the transfer of development rights (TDR) and discuss its application in Vancouver. Before addressing Vancouver's use of TDR, I establish the context of TDR use in North America, suggest appropriate policy objectives and constraints for TDR programs, and outline a series of operational …

    ubc Repository record for Transferable development rights : a policy analysis of a planning instrument and its application in Vancouver (opens in a new tab) Download PDF for Transferable development rights : a policy analysis of a planning instrument and its application in Vancouver (opens in a new tab)

  15. Procedural Rates, Economic Costs, and Geographic Variation of Primary and Revision Lumbar Total Disc Replacement

    Lumbar total disc replacement (TDR) surgery is a new procedure that treats degenerative disc disease, a remarkably common, disabling, and costly condition. Three distinct studies were conducted to address the longevity, costs, and geographic variation of the lumbar TDR procedure. These three …

    utahstate Repository record for Procedural Rates, Economic Costs, and Geographic Variation of Primary and Revision Lumbar Total Disc Replacement (opens in a new tab)

  16. Time domain reflectometry waveform analysis with second order bounded mean oscillation

    <p>Time domain reflectometry (TDR) is a well-established electromagnetic technique used to estimate in situ soil water content, and thermo-TDR is an extension of the traditional TDR, which can measure both soil water content and thermal properties. Tangent line methods and adaptive waveform …

    iastate Repository record for Time domain reflectometry waveform analysis with second order bounded mean oscillation (opens in a new tab)

  17. Characterization of preferential solute transport in soil

    … the effluent BTC;Two time domain reflectometry (TDR) methods for determining MIM parameters were developed and evaluated by using carefully controlled laboratory experiments. For a shallow (0--2 cm) TDR probe method, the TDR determined parameters were similar to the parameters estimated from the …

    iastate Repository record for Characterization of preferential solute transport in soil (opens in a new tab)

Page 1 of 16