Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 65 for “"TEGDMA"”.
-
Tegdma induction of apoptotic proteins in pulp fibroblasts
Monomers like triethylene glycol dimethacrylate (TEGDMA) leach from dental composites and adhesives due to incomplete polymerization or polymer degradation. The release of these monomers causes a variety of reactions that can lead to cell death. This death can be either necrotic, which is …
-
Preparation and testing of novel dental adhesives based on Bis- GMA/TEGDMA monomer system
… silane is used in Bis-GMA/TEGDMA monomer system. All the raw materials and finished products are characterized with infrared spectra, vapor pressure osmometry, viscosity and gel test. The bonding strength to tooth materials is determined by Instron machine. The work …
-
Einfluss des Monomers TEGDMA als Bestandteil dentaler Composite auf das COP9 Signalosom und die Differenzierung von LiSa-2 Zellen
… Composite ist das Triethylenglycoldimethacrylat (TEGDMA), ein Ester aus α,β-Methacrylatsäure und Ethylenglycol. Viele Studien bescheinigen dem Monomer TEGDMA cytotoxische und genotoxische Wirkungen verbunden mit negativen Effekten auf die Vitalität von Zellen und auf die Differenzierung von …
-
DNA-Strangbruchinduktion, Mikrokernbildung, Zellzyklusalteration und Apoptose durch Zahnwerkstoffe in humanen Lymphozyten
… HEMA (Hydroxyethylmethacrylat) und TEGDMA (Triethylenglycol-dimethacrylat) gehören zu den so genannten Restmonomeren. Sie liegen nach der Polymerisation noch ungebunden vor und werden anschließend freigesetzt. Sie gelangen in den Organismus über die Pulpa, die Gingiva oder über den …
-
Werkstoffkundliche Untersuchung von Polymer-infiltrierten tetrapodalen Zinkoxidnetzwerken unter Einfluss eines MDP-haltigen Primer und reinen Polymeren
… in zwei Untergruppen (je n=37) aufgeteilt: UDMA/TEGDMA und BisGMA/TEGDMA. Zum Vergleich wurden jeweils 37 reine Polymerproben aus UDMA/TEGDMA und BisGMA/TEGDMA hergestellt. Die biaxiale Biegefestigkeit wurde vor und nach einer Wasserlagerung (150 Tage bei 37 °C; 37.500 Thermozyklen zwischen 5 °C …
-
Σύνθεση καινοτόμων οδοντιατρικών υλικών προερχόμενων από προϊόντα χημικής ανακύκλωσης του πολύ(τερεφθαλικού αιθυλενεστέρα) (ΡΕΤ)
… they were gradually incorporated into Bis-GMA/TEGDMA (triethylene glycol dimethacrylate) resin mixtures, synthesizing the following monomer blend systems: PET-GLY 1-DM/Bis-GMA/TEGDMA 10:40:50 % w/w, PET-GLY 2-DM/Bis-GMA/TEGDMA 10:40:50 % w/w, and PET-GLY 1-DM/Bis-GMA/TEGDMA 25:25:50 % w/w. In …
-
Hydrophobically modified isosorbide dimethacrylates as biomaterials for bisphenol a free dental fillings
… mixed with triethylene glycol dimethacrylate (TEGDMA) at a 60:40 weight ratio, and evaluated for viscosity, degree of conversion, polymerization shrinkage, water sorption, glass transition temperature, flexural strength, and modulus. BisGMA is prepared and evaluated as a reference. Isosorbide …
-
Διάχυση μονομερών συνθετικών υλικών μέσω οδοντίνης σε συνθήκες εξομοίωσης πολφικής πίεσης
… methacrylate), ΒΡΑ (bisphenol A), TEGDMA (Triethylene glycol dimethacrylate), UDMA (Urethane dimethacrylate) and BisGMA (Bisphenol A glycerolate dimethacrylate), in the pulp chamber of human teeth, through the remaining dentin.Materials and Methods: For the determination of the …
-
Herstellung und Charakterisierung photopolymerisierbarer Opaquer mit verbesserter Adhäsion zur Metalloberfläche
… Der synthetisierte Opaquer mit einem Bis-GMA/TEGDMA-Verhältnis von 90:10 zeigte auf Grund seiner Zusammensetzung die besten Verarbeitungseigenschaften und weist nach Kochen der Klebungen für 24h die besten Haftwerte mit einer verbleibenden Haftfestigkeit von 94,7% auf. Nach …
-
Preparation and Evaluation of Novel Initiators for the Thermally Mild Living and Controlled Free Radical Polymerization of Methacrylates: Potential Application in Dental Composite Resins
… (MMA), tri-ethylene glycol dimethacrylate (TEGDMA) and ethoxylated bisphenol A dimethacrylate (EBPADMA) were accomplished, for the first time ever for most of the initiators. Linear polymers (PMMA) were produced in high yield (93 %) under mildly thermal conditions (T = 70 oC) and with …
-
Elution von Monomeren aus einem Infiltranten im Vergleich zu verschiedenen Dentalmaterialien in vitro
… h und 76 h) erneuert. Der Nachweis der Eluate (TEGDMA, BisGMA, G-1,3-DMA und HEMA) (n = 10) erfolgte mittels High Performance Liquid Chromatography (HPLC). Die Gesamtkonzentrationen aller freigesetzten Monomere aus den polierten Probenkörpern nach 10 Tagen Lagerung [Spanne Mittelwerte (MW): …
-
Effect of different percentages of silica nanofibers filler loads on mechanical and physical properties of flowable and hybrid composite resins
… or urethane dimethacrylate (UDMA) along with TEGDMA (tetraethylglycidylmethacrylate). Exhaustive researches has been conducted in recent years to improve physical and mechanical properties of resin-based dental composites, since the existing resin-filler systems may not be suitable for long …
-
Accelerated radiation polymerization of vinyl-divinyl comonomer systems
… and tetraethylene glycol dimethacry-late (TEGDMA), were used as DVM accelerators and crosslinking agents. The course of polymerization was followed by temperature (T)-time(t) polymerization exotherm curves. A new technique was developed to determine the "Gel-Effect Point" (GEP) and …
-
The effect of the oxygen inhibition layer on interfacial bond strengths and stain resistance of dental resin composites
… and stain resistance. Experimental BisGMA and TEGDMA comonomer resin mixtures loaded with either barium- or strontium-silicate glass fillers were fabricated. Commercially available dental resin composite restorative materials, including a novel epoxy-based system were also examined. The OIL of …
-
Einfluss des Bleichens auf die Freisetzung von Monomeren aus modernen dentalen Kompositmaterialien
… keinen Einfluß auf die eluierte Bis-GMA und <br>TEGDMA Menge aus Ceram XTM. Die freigesetzte Menge an Bisphenol A aus den <br>gebleichten Ceram XTM Proben war signifikant geringer im Vergleich zu den <br>Kontrollgruppen. Bleichen setzt signifikant geringere Mengen an BisGMA aus Filtek …
-
Einfluss verschiedener Lösungsmittel auf die Freisetzung von Monomeren aus dentalen Kompositen
… bei Lagerung in Ethanol und Aceton gefunden. TEGDMA wurde in allen vier Lösungsmitteln nachgewiesen und war im Speichel nach 7 Tagen Lagerungszeit in größeren Mengen vorhanden als in Ethanol. UDMA 2 wurde in Ethanol und Aceton herausgelöst. Die Menge an eluierbaren Monomeren wurde statistisch …
-
Σύνθεση και μελέτη ιδιοτήτων οδοντιατρικών νανοσύνθετων υλικών πολυμεθακρυλικής μήτρας
… These nanocomposites consist of a Bis-GMA/TEGDMA (50/50wt/wt) matrix, fumed silica nanoparticles (Aerosil OX50) as filler, which are silanized with the silanes or their blends: (i) MPS, (ii) OTMS, (iii) UDMS, (iv) MPS/OTMS (50/50 wt/wt) και (v) UDMS/OTMS (50/50 wt/wt). It is pointed out …
-
Synthesis and Photopolymerization of Novel Dimethacrylates
… of BisGMA/triethyleneglycoldimethacrylate (TEGDMA) mixtures was also studied by isothermal photo-DSC. Dilution with TEGDMA significantly reduced the viscosity and glass transition temperatures of the mixtures due to the increase in the flexibility. The extent of polymerization increased with …
-
Development of a graduated alumina polymer composite as a potential orthodontic bracket material
… (20-8) were infiltrated with UDMA/TEGDMA to test for compressive strength,<br/>modulus of elasticity and fracture toughness.<br/>Results: Graded ceramic structures of varying pore architecture were produced. Most of the<br/>ceramic scaffolds displayed porosity gradients across the …
-
Effect Of Different Percentages Of Silica Nanofibers Filler Loads On Mechanical And Physical Properties Of Flowable Composite Resins
… or urethane dimethacrylate (UDMA) along with TEGDMA (tetraethylglycidylmethacrylate). Novel techniques for the reinforcement of these resin-based composites continue in a research and development phase, since the existing resin-filler systems may not be suitable for long term applications in …
Page 1 of 4