Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"TEOM"”.
-
Evaluation of the TEOM method for the measurement of particulate matter for Texas cattle feedlots
The Tapered Element Oscillating Microbalance (TEOM) sampler is an EPA approved Federal Equivalent Method Sampler for measuring PM10 concentrations. The Center for Agricultural Air Quality Engineering and Science (CAAQES) owns two Rupprecht and Patashnick (R&P) Series1400a monitors. The R&P Series …
-
ADSORPTION/DESORPTION STUDIES ON SOLID ACID ALKYLATION CATALYSTS USING A TAPERED ELEMENT OSCILLATING MICROBALANCE (TEOM)
… A tapered element oscillating microbalance (TEOM) was used to elucidate for the first time the adsorption/desorption characteristics of alkylation reactants and products on promising large-pore beta- and USY-zeolites. A deeper understanding of the limitations of this instrument was gained for …
-
Analysis of Corticosteroid Drug Delivery using Tissue Engineered Oral Mucosa for the Treatment of Inflammatory Mucosal Diseases
Introduction: Tissue-engineered oral mucosa (TEOM) is increasingly being used to assess drug delivery and toxicity, as well as for modeling oral diseases. Current TEOM models are constructed using primary oral fibroblasts and keratinocytes that display donor-to-donor variability and whose …
-
Investigation into the use of a tapered element oscillating microbalance for real-time particulate measurement
… Tapered Element Oscillating Microbalance (TEOM) mass measuring device. The objectives of testing with a TEOM diesel particulate analyzer were to validate its collection capability and evaluate its real-time characteristics on transient test cycles. Conventional PM filtration was used as the …
-
Comparison Between Tapered Element Microbalance (TEOM) and Federal Reference Method (FRM) for PM<sub>2.5</sub> Measurement in East Tennessee
… Element Oscillating Microbalance Monitors (TEOM) and the Federal Reference Method (FRM). The difference is generally related to lower ambient temperatures (i.e., at lower temperatures, the TEOM has been cited to under report PM2.5 concentrations).</p> <p>To determine if this same …
-
Observations of the tapered element oscillating microbalance as compared to a gravimetric method for particulate matter measurement
… a tapered element oscillating microbalance (TEOM) and the traditional gravimetric filter method designed per 40 CFR §1065.145. A repeatability test, consisting of multiple emission tests, was also performed for the TEOM system that shows that the TEOM was a consistent instrument. The TEOM was …
-
The effect of exhaust gas recirculation on particulate matter emissions from a compression-ignition, natural gas fuelled engine
… and a tapered element oscillating microbalance (TEOM). A repeatability study was conducted to determine the experimental error associated with PM measurements and to compare results from pre-weighed filters with those taken using a TEOM. The PM emission rate uncertainty was determined to be at …
-
Modeling of Particulate Matter Emissions from Agricultural Operations
… and Tapered Element Oscillating Microbalance (TEOM) sampler data. Corrections were applied to the TEOM measurements to account for TEOM vs. filter-based low-volume (FBLV) sampler bias and over-sampling of PM10 pre-collectors. Invalid concentrations and dust peaks larger than mean ± 3 times the …
-
Spatial assessment of forest fire smoke exposure and its health impacts in Southeastern British Columbia during the summer of 2003
… individual according to residential location: TEOM averaged PM concentrations measured by the nearest of six air quality monitors; SMOKE indicated the presence of a plume over the area in satellite imagery; and CALPUFF averaged PM concentrations estimated by a dispersion model. The latter was …
-
Spatial and temporal variations of PM2.5 mass and composition in Atlanta: ASACA 1999 2006
… is also used where applicable. Yearly-averaged TEOM measurements recorded violations of the annual PM2.5 NAAQS (>15 μg/m3) every year of the study, and the daily NAAQS (>65 μg/m3) was exceeded on five separate occasions. Seven-year PM2.5 averages for the sites ranged from 18.8 – 19.8 μg/m3. PCMs …
-
Monitoring of airborne particulate mass and number concentrations in the UK atmosphere
… size distribution in the range 11-450 nm) and TEOM (PM2.5 and PM10) at urban roadside, urban background, and rural sites. Chemical measurements were also made with Partisol and Dichotomous instruments at a rural and the Birmingham site. PM10 was generally dominated by fine particles at all …
-
Development of Cookstove Emissions and Performance Testing Suite with Time-resolved Particulate Matter Analysis and Excess Air Estimation
… a Tapered Element Oscillating Microbalance (TEOM) system. Significant modification and calibration of the TEOM system is presented to bring it into agreement with the standard gravimetric filter method. The real-time measurement system is able to correlate operator actions/operating …
-
Characterization and Evaluation of Performance of a Whole-Body Human Exposure Chamber
… instrument, the Rupprecht and Patashnick PM-10 TEOM, was used for determination of particle concentration. Particle size distributions were determined by a QCM cascade impactor. Data from gravimetric analysis were used to test for the evenness of dust concentrations in the chamber. CO2 is used …
-
Methane decomposition and partial oxidation in a cyclic mode over supported Co and Ni catalysts
… TEM. A tapered element oscillating microbalance (TEOM), used in the present study to monitor the reactions, operates as fixed bed micro-reactor that can measure the real time mass change of the catalyst during reaction. Product gases from the TEOM reactor were analyzed continuously by a quadrupole …
-
Inhalation exposure system for diesel exhaust particulates
… The Tapered Element Oscillating Microbalance (TEOM) was found to satisfactorily monitor the mass concentration but the filter lifetime at high mass concentrations would necessitate periodic observations.
-
Measurement, Characterization, and Source Apportionment of the Major Chemical Components of Fine Particulate Material, Including Semi-Volatile Species
… or Tapered Element Oscillating Microbalance (TEOM). However, SVM is often a major fraction of urban aerosols. Recent advances in atmospheric sampling instrumentation allowed for the semi-continuous characterization of urban PM2.5, including SVM. The Filter Dynamic Measurement System (FDMS) was …
-
Catalysts Development and Mechanistic Study of Ethanol Steam Reforming for Low Temperature H2 Production
… and tapered element oscillating microbalance (TEOM) are employed to study the effect of the promoters (Ca and Fe) and the reaction mechanisms. The deactivation mechanism in the Ni/Al2O3 system is found to be closely related to Ni particle size, catalyst electronic properties, and the steam …
-
The association between wildfire emitted PM2.5 and hospital admissions in the greater Seattle area
… from a tapered element oscillating microbalance (TEOM) PM2.5 monitor located in Seattle-Beacon Hill to estimate exposure concentrations throughout the GSA. Generalized linear models were created using 3rd degree B-splines to estimate the relative risk (effect estimates) of daily hospital …
-
The Measurement and Characterisation of Aerosol in the Urban Atmosphere (PM10) and an Evaluation ofthe Sources of these Particles by Number
… the tapered element oscillating microbalance (TEOM) mass of panicles had a low correlation with the particles less than 5 µm and an increased correlation to the particles greater than 5 µm in size. Outside of these peak periods the PM10 TEOM mass was most closely correlated with the number of …
-
Chemical and Physical Studies of Secondary Organic Aerosol Formed from Beta-pinene Photooxidation
… microbalance-scanning mobility particle sizer (TEOM-SMPS) method. Our results showed a correlation between the determined particle density and the particle chemical composition of the respective system. This demonstrates that changes in particle density can be indicative of the changes in …
Page 1 of 2