Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 35 for “"TEPC"”.
-
Characteristics of High Reliability TEPC for Long Term Space Missions
The Tissue Equivalent Proportional Counters (TEPC) have become a major part of the dosimetry system used on the International Space Station (ISS). TEPCs provide near real-time measurements of absorbed dose and dose equivalent in different parts of the ISS. The current TEPC model used at ISS uses …
-
Development and Test of a GEM-Based TEPC for Neutron Protection Dosimetry
… a new tissue equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10), which is a conservative estimate of H, for neutrons was designed and constructed. The deposited energy distribution for two different neutron sources (a Cf-252 source and a AmBe …
-
Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer
Tissue equivalent proportional counters (TEPCs) are recognized as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic …
-
Modeling the wall effects of a tissue equivalent proportional counter using MCNP
<p>Tissue equivalent proportional counters (TEPCs) utilize tissue equivalent materials to depict homogeneous microscopic volumes of human tissue. Although both the walls and gas simulate the same medium, they respond to radiation differently. Differences between the densities of the two materials …
-
Characterization of mixed linear energy transfer environments utilizing tissue-equivalent proportional counters
… A tissue equivalent proportional counter (TEPC) was used to produce dose-equivalent measurements and quantify neutron exposures. Three neutron sources were used to simulate high energy, mixed LET environments: californium-252, a plutonium-beryllium source, and a deuterium-tritium neutron …
-
Development of an Advanced Two-Dimensional Microdosimetric Detector based on THick Gas Electron Multipliers
… based tissue-equivalent proportional counter (TEPC) has been proven to be useful for microdosimetry due to its flexibility in varying the gaseous sensitive volume and achieving high multiplication gain. Aiming at measuring the spatial distribution of radiation dose for mixed neutron-gamma …
-
The response of a spherical tissue-equivalent proportional counter to different heavy ions with similar velocities
A tissue-equivalent proportional counter (TEPC) has been used as an area monitor to measure absorbed dose and estimate equivalent dose during Space Transport Shuttle and International Space Station missions. This detector measures energy deposition events in simulated small volumes of tissue on the …
-
Design and characterization of next-generation tissue equivalent proportional counters for use in low energy neutron fields
Tissue Equivalent Proportional Counters (TEPCs) are devices that can measure the radiation dose levels for the mixed neutron and gamma ray fields that are encountered in nuclear facilities. TEPC designs typically consist of a low density gas sensitive volume surrounded by a solid wall, each of …
-
Response of a tissue equivalent proportional counter to different ions having a similar linear energy transfer
The Tissue Equivalent Proportional Counter (TEPC) is a part of the active dosimetry of current space missions, measuring high-energy charged particles making up the proton and galactic cosmic radiation (GCR) fields, as well as the fragmentation products produced when these radiations interact with …
-
Simulation and Analysis of a Tissue Equivalent Proportional Counter Using the Monte Carlo Transport Code FLUKA
… a tissue-equivalent proportional counter (TEPC) and produce the expected delta ray events when exposed to high energy heavy ions (HZE) like in the galactic cosmic ray (GCR) environment. Accurate transport codes are desirable because of the high cost of beam time, the inability to measure …
-
The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon
… Tissue-equivalent proportional counters (TEPC) are used as active dosimeters on manned space flights. These TEPC's are further used to determine average quality factor for each space mission. A TEPC simulating a 1-μm diameter sphere of tissue was exposed as part of a particle spectrometer …
-
Investigation and use of dual (twin) low pressure proportional counters for active neutron-gamma mixed field dosimetry
… Tissue equivalent proportional counters (TEPCs) have been used, but their accuracy is limited. In this study, a custom-built Cylindrical Graphite Proportional Counter (Cy-GPC) along with a twin Cylindrical TEPC (Cy-TEPC) has been extensively investigated for n-γ mixed field dosimetry. …
-
Development of a neutron area monitor and characterization system
… <p>A tissue equivalent proportional counter (TEPC) system has also been utilized along with the sphere system. The TEPC was used to gather comparison data, and the results of the comparison have been presented.</p>
-
DEVELOPMENT OF A THICK GAS ELECTRON MULTIPLIER-BASED MULTI-ELEMENT MICRODOSIMETRIC DETECTOR
Tissue Equivalent Proportional Counters (TEPCs) are considered the standard instrument for microdosimetry, aiming at measuring the distribution of the energy deposited by ionizing radiation in a micrometric target, and have been employed for a number of radiation physics, radiation protection and …
-
Development of a Thick Gas Electron Multiplier Detector for Microdosimetry
… tissue-equivalent proportional counter (TEPC) is the most common detector currently used for microdosimetry. A new microdosimetric detector based on a thick gas electron multiplier (THGEM) was developed. To investigate the feasibility of the THGEM type detector for microdosimetry, a …
-
Benchmarking computations using the Monte Carlo code RITRACKS with data from a tissue equivalent proportional counter
… Tissue-equivalent proportional counters (TEPCs) have been used experimentally to measure energy deposition in volumes similar in dimension to a mammalian cell. As these experiments begin to include a wider range of ions and energies, considerations to cost, time, and radiation protection …
-
Quantifying Uncertainty In A Measurement-Based Assessment of Relative Biological Effectiveness In Carbon Ion Radiotherapy
… using a Tissue Equivalent Proportional Counter (TEPC). Microdosimetric spectra, kinetic energy spectra, and dose fragment contributions were calculated using Monte Carlo (GEANT IV) for monoenergetic and SOBP carbon beams of clinical energy. From microdosimetric spectra, lineal energy values were …
-
Design and implementation of the Hybrid Detector for Microdosimetry (HDM): Challenges in readout architecture and experimental results
… the microdosimeter used in this work, i.e. the TEPC or Tissue Equivalent Proportional Counter, a gas microdosimeter that is equivalent in terms of energy deposition to 2 um of tissue. A comprehensive characterization of the TEPC response to different ions and energies can be found in the …
-
Design, construction and implementation of spherical tissue equivalent proportional counter
Tissue equivalent proportional counters (TEPC) are used for medical and space activities whenever a combination of high and low LET (lineal energy transfer) radiations are present. With the frequency and duration of space activities increasing, exposure to fast heavy ions from galactic cosmic …
-
Properties of bread dough and finished bread with added fibre polysaccharides and phenolic antioxidants
… breads. Total extractable phenolic content (TEPC), antioxidant activity (AA), and HPLC results suggest that the ingredients used in bread formulation can induce various changes in secondary structure of wheat protein. HPLC- Mass (MS) spectrometry PP profiling revealed that baking caused …
Page 1 of 2