Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"THGEM"”.

  1. Development of THGEM based detectors for AT-TPC applications

    … Two THick Gaseous Electron Multipliers (THGEM) in cascade were found to operate at a gain of up to 10^4 in pure helium for pressures between 200 torr and 600 torr, while also providing a good energy resolution. The THGEM is a hole-type gaseous electron multiplier produced by multilayer …

    msu

  2. Development of a THGEM Imaging Detector with Delay Line Readout

    … lower. A Thick Gaseous Electron Multiplier (THGEM) imaging detector, with a two-dimensional delay line readout, has been constructed as a concept for a large area imaging detector with reasonable spatial resolution. The delay line based THGEM imaging detector is robust, easy to manufacture …

    mcmaster Repository record for Development of a THGEM Imaging Detector with Delay Line Readout (opens in a new tab)

  3. Development of a Thick Gas Electron Multiplier Detector for Microdosimetry

    … based on a thick gas electron multiplier (THGEM) was developed. To investigate the feasibility of the THGEM type detector for microdosimetry, a prototype detector was designed and manufactured. The THGEM detector is robust, easy to manufacture and is cost effective. The THGEM foil is …

    mcmaster Repository record for Development of a Thick Gas Electron Multiplier Detector for Microdosimetry (opens in a new tab)

  4. Development of a Thick Gas Electron Multiplier Based Beta-ray Detector

    … using the Thick Gas Electron Multiplier (THGEM) technology is presented. Traditional proportional counters have been considered the standard for many decades for radiation contamination monitoring. However, it has always been challenging to detect low energy beta-emitters such as 3H and …

    mcmaster Repository record for Development of a Thick Gas Electron Multiplier Based Beta-ray Detector (opens in a new tab)

  5. Development of an Advanced Two-Dimensional Microdosimetric Detector based on THick Gas Electron Multipliers

    The THick Gas Electron Multiplier (THGEM) based tissue-equivalent proportional counter (TEPC) has been proven to be useful for microdosimetry due to its flexibility in varying the gaseous sensitive volume and achieving high multiplication gain. Aiming at measuring the spatial distribution of …

    mcmaster Repository record for Development of an Advanced Two-Dimensional Microdosimetric Detector based on THick Gas Electron Multipliers (opens in a new tab)

  6. New Negative Ion Time Projection Chamber Technology for Directional Detection of Dark Matter, Neutrinos and Fast Neutrons

    … Initially the gain and energy resolution of the ThGEM device is determined in low pressure SF6. Results for the first operation of the novel MM-ThGEM amplification device in a negative ion drift gas are presented, showing that the device overcomes a number of problems encountered with the ThGEM …

    whiterose Download PDF for New Negative Ion Time Projection Chamber Technology for Directional Detection of Dark Matter, Neutrinos and Fast Neutrons (opens in a new tab)

  7. DEVELOPMENT OF A THICK GAS ELECTRON MULTIPLIER-BASED MULTI-ELEMENT MICRODOSIMETRIC DETECTOR

    … using the Thick Gas Electron Multiplier (THGEM) technique. The multi-element design was employed to increase the neutron detection efficiency. The prototype THGEM multi-element detector consists of three alternating layers of tissue equivalent plastic hexagons and each layer houses a …

    mcmaster Repository record for DEVELOPMENT OF A THICK GAS ELECTRON MULTIPLIER-BASED MULTI-ELEMENT MICRODOSIMETRIC DETECTOR (opens in a new tab)

  8. Developments Towards a Scaled-Up One-Dimensional Directional Dark Matter Detector

    … have also been taken with a small scale THGEM TPC in both CF4 and SF6 gas. The results from CF4 showed the high gas gains achievable from the THGEM detector and allowed a direct measurement of the Townsend coefficients of the gas. Gains of up to 8600 ± 150 have been achieved in low …

    whiterose Download PDF for Developments Towards a Scaled-Up One-Dimensional Directional Dark Matter Detector (opens in a new tab)

  9. Towards CYGNUS: A Large Scale, Low Threshold TPC for the Direct Detection of Dark Matter

    … an MWPC (Multi-Wire Proportional Chamber) and ThGEM (Thick Gaseous Electron Multiplier) amplification stage was found to produce the least background for a CYGNUS TPC. This result led to the construction of an MWPC-ThGEM hybrid prototype using a 10 cm diameter ThGEM and a 30 cm long wire array …

    whiterose Download PDF for Towards CYGNUS: A Large Scale, Low Threshold TPC for the Direct Detection of Dark Matter (opens in a new tab)

  10. Studio dello scattering 18O + 48Ti a 275 MeV, simulazioni Monte Carlo e caratterizzazione sperimentale del rivelatore di piano focale di MAGNEX per il progetto NUMEN

    … da un tracciatore a gas basato sulle M-THGEM e da un muro di rivelatori a telescopio ΔE-E, basato sulla tecnologia SiC-CsI(Tl), per l’identificazione delle particelle (Particle IDentification, PID). In questo contesto, è stata svolta un’intensa attività di ricerca e sviluppo, che ha …

    catania Repository record for Studio dello scattering 18O + 48Ti a 275 MeV, simulazioni Monte Carlo e caratterizzazione sperimentale del rivelatore di piano focale di MAGNEX per il progetto NUMEN (opens in a new tab)

  11. Optimization of a GEM-based detector to measure tritium and discriminate against other radiation types

    … and long-range beta particles and electrons. The THGEM gain was also investigated with experimental and computational modelling. Recommendations include modification of the collection plate and increasing the gain of the detector to improve the efficiency of tritium detection and discrimination …

    uoit Repository record for Optimization of a GEM-based detector to measure tritium and discriminate against other radiation types (opens in a new tab)

  12. Development of an advanced gaseous neutron imaging system based on thick gas electron multipliers with 2d delay line readout

    … utilizing a 10B4C solid state converter and THGEM technology and 2D passive delay line readout. THGEMs used for signal amplification can be produced cost effectively and in large areas by PCB manufacturers. This combined with the reduced channel processing requirements of delay lines over …

    mcmaster Repository record for Development of an advanced gaseous neutron imaging system based on thick gas electron multipliers with 2d delay line readout (opens in a new tab)

  13. Towards CYGNUS-UK: Developments in Negative Ion Charge Amplification and Readout Technologies for Directional Dark Matter Detection

    … with a single Thick Gaseous Electron Multiplier (ThGEM) for the first time. Significant work with a novel multi-stage Multi-Mesh ThGEM (MMThGEM) demonstrated large charge amplification on the order of 10⁴ in an NID gas, low pressure SF₆, for the first time. The MMThGEM also showed promise for …

    whiterose Download PDF for Towards CYGNUS-UK: Developments in Negative Ion Charge Amplification and Readout Technologies for Directional Dark Matter Detection (opens in a new tab)

  14. ATLAS Electromagnetic Calorimeter performance measurements, search for the Higgs boson in the H→Zγ channel and detector development for position reconstruction of noble liquid scintillation

    … and a CsI photocathode deposited on the first THGEM. A 10 cm2 area is instrumented with four readout channels. A gain of 8·10E5 per photoelectron and ~100% photoelectron collection efficiency are measured at stable operation settings. A ~100 μm position resolution at 100 kHz readout rate is …

    whiterose Download PDF for ATLAS Electromagnetic Calorimeter performance measurements, search for the Higgs boson in the H→Zγ channel and detector development for position reconstruction of noble liquid scintillation (opens in a new tab)

  15. Studio di reazioni nucleari di interesse per la ricerca del decadimento 0νββ nel conteso del progetto NUMEN: i casi 76Se(18O,17O)77Se e 76Se(18O,19F)75As a 15 MeV/u e sviluppo di un nuovo tracciatore a gas per applicazioni ad alto rate

    Il doppio decadimento beta senza neutrini (0νββ) rappresenta un tema cruciale nella Fisica moderna, che potenzialmente aprirebbe nuovi scenari oltre il Modello Standard della fisica delle particelle. Il progetto NUMEN propone una tecnica innovativa per accedere agli elementi di matrice nucleare, …

    catania Repository record for Studio di reazioni nucleari di interesse per la ricerca del decadimento 0νββ nel conteso del progetto NUMEN: i casi 76Se(18O,17O)77Se e 76Se(18O,19F)75As a 15 MeV/u e sviluppo di un nuovo tracciatore a gas per applicazioni ad alto rate (opens in a new tab)

  16. Novel applications of FBK SiPMs in the detection of low energy ionizing radiation

    … of a high electric field in the TPC towards a THGEM where they created light with timing depending on the distance of each track segment from the scintillator. The LG detector was able to reconstruct the 3D track particle inside the chamber with an error below 8 mm RMS inside the 40 l chamber …

    trento Repository record for Novel applications of FBK SiPMs in the detection of low energy ionizing radiation (opens in a new tab)