Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"TOF-PET"”
-
TOF-PET Imaging within the Framework of Sparse Reconstruction
Recently, the limited-angle TOF-PET system has become an active topic mainly due to the considerable reduction of hardware cost and potential applicability for performing needle biopsy on patients while in the scanner. However, this kind of measurement configurations oftentimes suffers from the …
-
Design and Development of ToF-PET Detectors based on Metascintillators
… por Emisión de Positrones con Tiempo de Vuelo (ToF-PET), con el objetivo de mejorar la resolución temporal utilizando metacentelleadores. La información temporal mejora la relación señal-ruido de las imágenes clínicas, ofreciendo mayor contraste que permite detectar precozmente tumores de …
-
Development and Performance Evaluation of High Resolution TOF-PET Detectors Suitable for Novel PET Scanners
[ES] La Tomografía por Emisión de Positrones (PET) es una de las técnicas más importantes en la medicina de diagnóstico actual y la más representativa en el campo de la Imagen Molecular. Esta modalidad de imagen es capaz de producir información funcional única, que permite la visualización en …
-
Parameterizing Image Quality of TOF versus Non-TOF PET as a Function of Body Size
<p>Positron emission tomography (PET) is a nuclear medicine diagnostic imaging exam of metabolic processes in the body. Radiotracers, which consist of positron emitting radioisotopes and a molecular probe, are introduced into the body, emitted radiation is detected, and tomographic images are …
-
Anatomically informed image reconstruction for time of flight positron emission tomography
Positron emission tomography (PET) has an important role in disease diagnosis, drug development and patient management. PET images are accompanied with computed tomography (CT) or magnetic resonance (MR) to provide the complementary structural information. GE SIGNA PET/MR is the state-of-the-art …
-
Statistical Reconstruction of Positronium Lifetime Imaging Using Time-of-Flight Positron Emission Tomography
… is a technique used in time-of-flight (TOF) positron emission tomography (PET) that involves measuring the lifespan of positronium, more preciselyortho-positronium (o-Ps), before annihilation, in addition to the traditional uptake image of PET tracer. PLI faces the challenge of limited …
-
IN-PIXEL TIME DIGITAL CONVERTER FOR TIME-OF-FLIGHT PET IMAGING
… of patients. Positron emission tomography (PET) imaging, as one of the recent imaging technologies, provides imaging from cellular-level metabolic changes in tissues. This gives PET imaging a substantial lead in detecting disease in their very early stages. PET imaging provides high …
-
CMOS BASED SINGLE PHOTON AVALANCHE DIODE AND TIME-TO-DIGITAL CONVERTER TOWARDS PET IMAGING APPLICATIONS
Time-of-flight (ToF) positron emission tomography (PET) is a non-invasive, functional biomedical imaging modality. It can be used to determine the metabolic activity difference between lesion and normal cells, thus, making it possible to detect tumors at their early stages. In such a system, …
-
Optimized PET module for both pixelated and monolithic scintillator crystals
Time-of-Flight Positron Emission Tomography (TOF-PET) scanners demand fast and efficient photo-sensors and scintillators coupled to fast readout electronics. Nowadays, there are two main configurations regarding the scintillator crystal geometry: the segmented or pixelated and the monolithic …
-
Optimization of novel developments in Positron Emission Tomography (PET) imaging
Positron Emission Tomography (PET) is a widely used imaging modality for diagnosing patients with cancer. Recently, there have been three novel developments in PET imaging aiming to increase PET image quality and quantification. This thesis focuses on the optimization of PET image quality on these …
-
Transmission-based attenuation correction for time-of-flight positron emission tomography
Positronemissietomografie (PET) is een beeldvormingstechniek binnen de nucleaire geneeskunde waarbij met behulp van een radioactieve speurstof fysiologische processen in het lichaam in beeld gebracht worden. De techniek speelt een belangrijke rol in de diagnose van verschillende aandoeningen. Het …
-
Image reconstruction for three-gamma PET imaging
… comme pour la différence en temps d’arrivé en TOF-PET. Nous présentons une étude de simulation GATE de deux phantoms (NEMA et Digimouse) pour évaluer les améliorations de la reconstruction d’image 3-gamma par rapport à la TEP conventionnelle, et nous étudions aussi la correction du range du …
-
Dosimetry of Y-90 Liquid Brachytherapy in a Dog with Osteosarcoma Using PET/CT
… of Y-90 is assessed using a time-of-flight (TOF) PET/CT scanner. A patient-specific geometry is built using anatomical data obtained from CT images. The material properties of tumor and surrounding tissues are calculated based on a CT number - electron density calibration. The Y-90 …
-
Data-driven methods for respiratory signal detection in positron emission tomography
Positron Emission Tomography (PET) is a nuclear medicine imaging technique which allows quantitative assessment of functional processes, by determining the distribution of radioactive tracers inside the patient body. It is mainly used in oncology. Respiration during PET data acquisition of the …
-
A Geant4 Simulation Study Of A Xenon-Doped Liquid Argon, Full-Body, Time-of-Flight Positron Emission Tomography Scanner To Understand Its Performance And Noise Profile
Positron Emission Tomography (PET) is used to observe metabolic processes within living tissue. It works by reconstructing the annihilation origin of incident gamma rays produced by a positron emitting radiotracer. This field of nuclear imaging has seen a steady improvement of PET imaging largely …
-
Development of a fast-timing detector for Time-of-Flight Applications: enabling new opportunities in Positron Emission Tomography and Velocity Map Imaging Mass Spectrometry
… time-of-flight positron emission tomography (TOF-PET) and time-of-flight mass spectrometry, with a particular focus on velocity map imaging mass spectrometry (VMImMS). In time-of-flight positron emission tomography (TOF-PET), the com-bination of SiPMs and fast scintillators has enabled the …
-
Design of SiPM Front-End Readout Integrated Circuits for Large Area Single-Photon Imagers
… as Time-of-Flight Positron Emission Tomography (ToF-PET), particle detectors in high-energy physics experiments like the Large Hadron Collider beauty (LHCb) at CERN, and the advanced cameras for the Large-Size Telescope (LST) in the Cherenkov Telescope Array (CTA), pose significant challenges. …
-
Development of methods for time efficient scatter correction and improved attenuation correction in time-of-flight PET/MR
… der Bildrekonstruktion in der time-of-flight (TOF) PET bearbeitet: Beschleunigung der TOF-Streukorrektur sowie Verbesserung der emissionsbasierten Schwächungskorrektur. Aufgrund der fehlenden Möglichkeit, die Photonenabschwächung direkt zu messen, ist eine Verbesserung der Schwächungskorrektur …
-
Enhancing PET Functionalities with Novel Geometries and Multimodal Imaging Techniques
Positron emission tomography (PET) is a highly sensitive imaging modality that can provide in vivo quantitative information of biological processes at a biochemical level. The majority of PET systems have a ring geometry where the detectors fully encircle an axial section of a patient to provide …
-
Characterisation of Silicon Photomultipliers for the detection of Near Ultraviolet and Visible light
… and Astroparticle Physics experiments and in the PET or SPECT medical techniques. Two different types of light detectors are usually used: thermal detectors and photoelectric effect based detectors. Among the rst type detectors, the Bolometer is the most widely used and developed. Its invention …
Page 1 of 2