Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 203 for “"TOF-SIMS"”.

  1. Quantitative evaluation of diffusion in thin filmsvia ToF-SIMS depth profiling

    … mass transport. Secondary Ion Mass Spectrometry (SIMS) is one of the primary techniques for probing diffusion processes with nanoscale depth resolution. However, the quantitative extraction of transport parameters is currently hindered by unvalidated data processing methods,oversimplified …

    texas Repository record for Quantitative evaluation of diffusion in thin filmsvia ToF-SIMS depth profiling (opens in a new tab) Embargoed until 2028-05-01

  2. Correlation of ToF-SIMS surface analysis with particle hydrophobicity and flotation

    … Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and statistically correlated with hydrophobicity, as measured by the water contact angle. A statistical linear model has been derived that calculates the contact angle based on the surface chemical contribution of key ToF-SIMS secondary …

    adelaide Repository record for Correlation of ToF-SIMS surface analysis with particle hydrophobicity and flotation (opens in a new tab)

  3. Visualization of Fibre Products Using ToF-SIMS and Multivariate Data Analysis

    … time-of-flight secondary ion mass spectrometry (ToF-SIMS), along with multivariate data analysis (MVDA) to resolve the chemical hierarchy. The chemical difference between the papers calendered at 100 C and 200 C was investigated by using principal component analysis (PCA) and orthogonal partial …

    chalmers Repository record for Visualization of Fibre Products Using ToF-SIMS and Multivariate Data Analysis (opens in a new tab)

  4. ToF-SIMS IMAGING AND DATA MINING APPROACHES FOR ORGANIC STRUCTURED SAMPLES

    … the 70s and 80s of the 20th century, the use of ToF-SIMS technique was mainly confined to the characterization of inorganic materials, but more recently, especially after the introduction of instrumentation upgrades, it has spread in many other fields, including biology, disease investigation and …

    catania Repository record for ToF-SIMS IMAGING AND DATA MINING APPROACHES FOR ORGANIC STRUCTURED SAMPLES (opens in a new tab)

  5. Correlating microscopy and ToF-SIMS images to cellulose size using deep learning

    … were also analyzed as parts of spots by ToF-SIMS. A 3D CNN model was trained from scratch. The model could successfully distinguish between fractions in this case as well.

    chalmers Repository record for Correlating microscopy and ToF-SIMS images to cellulose size using deep learning (opens in a new tab)

  6. Of impurities, drugs and metabolites - ToF-SIMS application studies for use in the pharmaceutical sciences

    … Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) for applications in the pharmaceutical sciences through three separate studies with different pharmaceutical applications.The first study investigated the use of ToF-SIMS for the surface characterisation of pharmaceutical crystals using …

    strathclyde Repository record for Of impurities, drugs and metabolites - ToF-SIMS application studies for use in the pharmaceutical sciences (opens in a new tab)

  7. Structural Effects in 2D-Stabilized FAPbI3 Films and ToF-SIMS for Ultra-thin h-BN Fabrication

    … time-of-flight secondary ion mass spectrometry (ToF-SIMS). ToF-SIMS is further employed for 3D reconstruction of h-BN flakes.

    rice Repository record for Structural Effects in 2D-Stabilized FAPbI3 Films and ToF-SIMS for Ultra-thin h-BN Fabrication (opens in a new tab)

  8. Oberflächenanalytische Charakterisierung von auf Koordinations- und Klickchemie basierenden organischen Schichten mittels XPS, NEXAFS und ToF-SIMS

    … und Flugzeit-Sekundärionen-Massenspektrometrie (ToF-SIMS) sind diese organischen Schichtsysteme charakterisiert und die folgenden Teilergebnisse erzielt worden: • Die erfolgreiche Bildung der SAM-Metall(II)-Komplexe bzw. der SAM- Metall(II)-Makrocyclen- komplexe wurde sowohl durch die …

    fu-berlin Repository record for Oberflächenanalytische Charakterisierung von auf Koordinations- und Klickchemie basierenden organischen Schichten mittels XPS, NEXAFS und ToF-SIMS (opens in a new tab)

  9. Characterization and Quantification of Biological Surfaces Using Cluster ToF-SIMS with the Event-By-Event Bombardment/Detection Mode

    Cluster ToF-SIMS (time-of-flight secondary ion mass spectrometry) operated in the event-by-event bombardment/detection mode has been applied to: 1) evaluate and screen the manufacturing quality of step-wise prepared micropatterned biointerfaces; 2) quantify the binding density of Au nanoparticles …

    tamu Repository record for Characterization and Quantification of Biological Surfaces Using Cluster ToF-SIMS with the Event-By-Event Bombardment/Detection Mode (opens in a new tab)

  10. The application of time-of-flight secondary ion mass spectrometry (ToF-SIMS) to forensic glass analysis and questioned document examination

    … time-of-flight secondary ion mass spectrometry (ToF-SIMS), with advanced statistical interrogation by principal component analysis (PCA), has allowed a significant advancement in the forensic discrimination of pen, pencil and glass materials based on trace characterisation.

    adelaide Repository record for The application of time-of-flight secondary ion mass spectrometry (ToF-SIMS) to forensic glass analysis and questioned document examination (opens in a new tab)

  11. Identification and imaging different lipid species within phase-separated model membranes by integration of TOF-SIMS and principal component analysis

    Time of flight secondary ion mass spectrometry (TOF-SIMS) enables chemically imaging the distributions of various lipid species in model membranes. However, discriminating the TOF-SIMS spectra of structurally similar lipids is very difficult because the low mass fragment ions that are abundant in …

    uiuc Repository record for Identification and imaging different lipid species within phase-separated model membranes by integration of TOF-SIMS and principal component analysis (opens in a new tab)

  12. Diamond Intracrystalline Stable Isotope Chemical Image Analysis by Time-of-Flight Secondary Ionization Mass Spectrometery

    … Secondary Ionization Mass Spectrometer (ToF-SIMS) as an alternative method for diamond geochemical analyses. ToF-SIMS analysis can perform in cation and anion mode to measure the entire periodic table of an analyte. Establishing a quantitative ToF-SIMS methodology would dramatically …

    mo-state Repository record for Diamond Intracrystalline Stable Isotope Chemical Image Analysis by Time-of-Flight Secondary Ionization Mass Spectrometery (opens in a new tab)

  13. Diagnostika polovodičů a monitorování chemických reakcí metodou SIMS

    … sekundárnych iónov s analýzou doby letu (TOF-SIMS) patrí vďaka vysokej citlivosti na prvkové zloženie medzi významné metódy analýzy pevných povrchov. Táto práca demonštruje možnosti TOF-SIMS v troch odlišných oblastiach výskumu. Prvá časť práce sa zaoberá lokalizáciou defektov …

    brno-tech Repository record for Diagnostika polovodičů a monitorování chemických reakcí metodou SIMS (opens in a new tab)

  14. Spatial Mass Spectral Data Analysis Using Factor and Correlation Models

    ToF-SIMS is a powerful and information rich tool with high resolution and sensitivity compared to conventional mass spectrometers. Recently, its application has been extended to metabolic profiling analysis. However, there are only a few algorithms currently available to handle such output data …

    whiterose Download PDF for Spatial Mass Spectral Data Analysis Using Factor and Correlation Models (opens in a new tab)

  15. Investigating the Uptake and Transport of AgNPs in Arabidopsis thaliana by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS)

    … Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) was used to gain information on the spatial distribution as well as spectral information, characteristic of both plant tissue and AgNPs. Ag levels in shoots and leaves were quantified by Inductively Coupled Plasms Mass Spectrometry …

    buffalo Repository record for Investigating the Uptake and Transport of AgNPs in Arabidopsis thaliana by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) (opens in a new tab)

  16. Applying secondary ion mass spectrometry to cellular and model membranes to image component distribution and quantify composition

    Abstract Secondary ion mass spectrometry (SIMS) returns chemically specific data on membrane component distribution and composition. Of particular interest is a membrane protein’s lipid environment, which may play a role in the protein’s function. Herein, this thesis describes the synthesis of …

    uiuc Repository record for Applying secondary ion mass spectrometry to cellular and model membranes to image component distribution and quantify composition (opens in a new tab)

  17. Mass Spectral Imaging for Chemical Analysis of Cancerous Tissues Using Time-of-Flight Secondary Ion Mass Spectrometry

    … time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to analyze human breast cancer tissue and murine β cell neoplasia. ToF-SIMS for tissue sample analysis is an emerging field, so the development of characterization methods is critical to provide a framework for multiple tissue …

    washington Repository record for Mass Spectral Imaging for Chemical Analysis of Cancerous Tissues Using Time-of-Flight Secondary Ion Mass Spectrometry (opens in a new tab)

Page 1 of 11