Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"TWIMS"”.

  1. Ion Mobility Spectrometry Coupled to Mass Spectrometry for Glycoanalysis: Ion-Neutral Collision Cross Section Calibration and Application to Glycopeptides

    … traveling wave ion mobility spectrometry (TWIMS), commercialized in the Waters Synapt HDMS instrument, allows for traditional IMSMS analysis in addition to multiple dissociation techniques for a more enriched analysis. However, TWIMS CCS measurements are more complicated to calculate as the …

    nebraska Repository record for Ion Mobility Spectrometry Coupled to Mass Spectrometry for Glycoanalysis: Ion-Neutral Collision Cross Section Calibration and Application to Glycopeptides (opens in a new tab)

  2. Liquid micro-junction surface sampling and MALDI imaging of small and large molecules in human liver disease

    … FAIMS, traveling wave ion mobility spectrometry (TWIMS) was also coupled to LESA. In addition to the separation of lipids from proteins, several lipids also showed a separation in drift. MS/MS of one of these lipids revealed that the composition of the two drift peaks differed. MALDI imaging was …

    birmingham Download PDF for Liquid micro-junction surface sampling and MALDI imaging of small and large molecules in human liver disease (opens in a new tab)

  3. Protein complexes in the gas phase: structural insights from ion mobility-mass spectrometry and computational modelling

    … measurement accuracy using travelling-wave IM (TWIMS) instrumentation was carried out (Chapter 3). Through the collation of a protein complex CCS database and the development of a calibration framework for TWIMS, significant improvements to CCS measurement accuracy have been achieved. Next, the …

    oxford Repository record for Protein complexes in the gas phase: structural insights from ion mobility-mass spectrometry and computational modelling (opens in a new tab)

  4. Advancing Cyclic Ion Mobility Mass Spectrometry for Structural Characterization, Isomer Discrimination and Gas-Phase Ion Chemistry

    … traveling-wave ion mobility spectrometry (cyclic TWIMS), implemented in a commercial cyclic ion mobility-mass spectrometry (cIMS) platform, to systematically evaluate both the capabilities and limitations of high-resolution IMS in resolving subtle structural differences. Initial studies …

    byu Repository record for Advancing Cyclic Ion Mobility Mass Spectrometry for Structural Characterization, Isomer Discrimination and Gas-Phase Ion Chemistry (opens in a new tab) Download PDF for Advancing Cyclic Ion Mobility Mass Spectrometry for Structural Characterization, Isomer Discrimination and Gas-Phase Ion Chemistry (opens in a new tab)

  5. Defining the mechanism of small molecule inhibition of amyloid fibril formation using ion mobility spectrometry – mass spectrometry

    … Travelling wave ion mobility spectrometry (TWIMS), when combined with mass spectrometry (MS), has the unique and unrivalled capability of separating molecular ions based on their collision cross-sectional area in addition to their mass-to-charge ratio, thus facilitating structural studies of …

    whiterose Download PDF for Defining the mechanism of small molecule inhibition of amyloid fibril formation using ion mobility spectrometry – mass spectrometry (opens in a new tab)

  6. Front-End Methods For Enhancing the Analytical Power of Mass Spectrometry

    … with Travelling Wave Ion Mobility Spectrometry (TWIMS) to compare equilibrium and kinetic unfolding intermediates of cytochrome c, showing a high degree of correlation between all species populated under these substantially different regimes. We then combine TRESI with Hydrogen Deuterium Exchange …

    york Repository record for Front-End Methods For Enhancing the Analytical Power of Mass Spectrometry (opens in a new tab)

  7. Modeling and experimenting a novel inverted drift tube device for improved mobility analysis of aerosol particles

    … ion mobility spectrometers, the DTIMS, FAIMS, TWIMS, DMA are notable. Though all the IMS systems have some uniqueness in case of particle separation and detection, however, all instruments have common shortcomings. They lack in resolution, which is independent of mobility of different charged …

    iupui Repository record for Modeling and experimenting a novel inverted drift tube device for improved mobility analysis of aerosol particles (opens in a new tab)

  8. Enhanced screening methods for pesticides in food based on travelling-wave ion-mobility-high-resolution mass spectrometry

    … using traveling wave ion mobility spectrometry (TWIMS). We have identified nitrogen as suitable gas for the mobility separation of multi-class pesticides and optimized the different T-wave parameters for a wide range of molecular weight pesticides. We observed for 100 pesticides tested that drift …

    liege Repository record for Enhanced screening methods for pesticides in food based on travelling-wave ion-mobility-high-resolution mass spectrometry (opens in a new tab) Restricted access

  9. Investigating structural and stability characteristics of native-like proteins using ion mobility-mass spectrometry (IM-MS) in positive- and negative-ion mode.

    … for Traveling-Wave Ion Mobility Spectrometry (TWIMS) calibration, so we developed an error propagation method that quantifies some of this uncertainty. Quantifying this uncertainty allows for a more robust comparison of protein gas-phase structures. Chapter Three focuses on how a protein's …

    baylor Repository record for Investigating structural and stability characteristics of native-like proteins using ion mobility-mass spectrometry (IM-MS) in positive- and negative-ion mode. (opens in a new tab)

  10. Mass spectrometry imaging of lung in pulmonary arterial hypertension

    … (PPZ)) was also tested by TWIMS. PPZ derivatisation allowed separation of a group of isomeric metabolites (11βOHE2, 16αOHE2, 16βOHE2), increasing CCSN2 difference from < 2 Å2 to > 10 Å2. Further work evaluated CCS prediction tools. There was good agreement between the …

    edinburgh Repository record for Mass spectrometry imaging of lung in pulmonary arterial hypertension (opens in a new tab)

  11. Development of mass spectrometry methods for the diagnosis and stratification of non-alcoholic fatty liver disease

    … and travelling wave ion mobility spectrometry (TWIMS). Intact proteins were successfully detected and their distribution across the tissue visualised. A heterogeneous distribution of proteins was observed in non-alcoholic steatohepatitis (NASH) tissue in which the regenerative nodules and …

    birmingham Download PDF for Development of mass spectrometry methods for the diagnosis and stratification of non-alcoholic fatty liver disease (opens in a new tab)

  12. Applications and challenges in mass spectrometry-based untargeted metabolomics

    … with traveling wave ion mobility spectrometry (TWIMS) time-of-flight (TOF) MS for the analysis of EBC samples from cystic fibrosis patients and healthy controls. TM-DART-TWIMS-TOF MS was able to successfully detect cystic fibrosis in this small sample cohort, thereby, demonstrating it can be …

    gatech Repository record for Applications and challenges in mass spectrometry-based untargeted metabolomics (opens in a new tab)

  13. Elucidating the structural consequences of phosphorylation by mass spectrometry, ion mobility and molecular modelling

    … of travelling wave ion mobility spectrometry (TWIMS) in ETD experiments produced similar levels of fragment coverage to ECD fragmentation of β-casein, and allowed the identification of a subset of fragments in the GSK3β-pY11 spectrum that were produced by a slow dissociation process from a …

    birmingham Download PDF for Elucidating the structural consequences of phosphorylation by mass spectrometry, ion mobility and molecular modelling (opens in a new tab)

  14. Application of Native Mass Spectrometry and Ion Mobility-Mass Spectrometry Towards the Study of Small Molecule Complexes, Protein Complexes, and Antibodies

    … been performed on travelling-wave IMS (TWIMS) based instrumentation; however, these instruments require external calibrants for CCS determinations and lose considerable sensitivity at the high m/z regimes needed to sample larger native protein complexes. We worked to evaluate a new …

    tamu Repository record for Application of Native Mass Spectrometry and Ion Mobility-Mass Spectrometry Towards the Study of Small Molecule Complexes, Protein Complexes, and Antibodies (opens in a new tab)

  15. Multi-dimensional Analysis of Molecular Clusters in the Gas-phase

    … N2]–. Travelling wave ion mobility spectrometry (TWIMS) analysis of HB12F12– finds CCSTWIMS = 142 ± 6.7 Å2. IRMPD spectroscopy, aided by computational modelling, indicates that the bidentate conformation is the major sub-population in the gas-phase ensemble.

    waterloo Repository record for Multi-dimensional Analysis of Molecular Clusters in the Gas-phase (opens in a new tab)

  16. Biosimilarity assessment of biopharmaceuticals for quality control

    … Traveling wave ion-mobility spectrometry (TWIMS) and NMR (nuclear magnetic resonance) spectroscopy affirm close similarity of the higher-order structure of both biopharmaceuticals. Potency of the biodrugs was analyzed by a coagulation assay demonstrating comparable bioactivity. …

    fu-berlin Repository record for Biosimilarity assessment of biopharmaceuticals for quality control (opens in a new tab)