Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 48 for “"Talif"”

  1. Two-photon absorption laser induced fluorescence (TALIF) of neutral xenon in a Hall Effect thruster plasma

    … absorption laser induced fluorescence (TALIF). Neutral xenon particles in the thruster plasma play an important role in ionization processes, overall energy conversion, and life-limiting interactions with surrounding wall materials in the thruster. Therefore, a detailed understanding of …

    colostate Repository record for Two-photon absorption laser induced fluorescence (TALIF) of neutral xenon in a Hall Effect thruster plasma (opens in a new tab)

  2. Ultrashort Two-Photon-Absorption Laser-Induced Fluorescence in Nanosecond-Duration, Repetitively Pulsed Discharges

    … absorption laser-induced fluorescence (TALIF). Relatively high plasma discharge pulse energies (=1 mJ/pulse) are used to generate atomic hydrogen, oxygen, and nitrogen in a variety of discharge conditions and geometries. Unique to this work is the development of femtosecond-laser-based …

    ohiolink Repository record for Ultrashort Two-Photon-Absorption Laser-Induced Fluorescence in Nanosecond-Duration, Repetitively Pulsed Discharges (opens in a new tab)

  3. Absolute calibration and quantification of atomic oxygen in nanosecond plasmas using two-photon absorption laser-induced fluorescence

    … induite par laser en absorbant deux photons (TALIF) s’est imposée comme une technique non-intrusive efficace pour détecter les espèces atomiques. Utilisant des impulsions laser rapides (nanoseconde) ou ultra-rapides (picoseconde/femtoseconde), la technique TALIF permet l’excitation localisée …

    star-france Repository record for Absolute calibration and quantification of atomic oxygen in nanosecond plasmas using two-photon absorption laser-induced fluorescence (opens in a new tab)

  4. A spectroscopic study on the detection of carbon monoxide for solar fuel production

    … CO. Non-equilibrium plasma discharges like the TALIF or microwave discharges have been proposed to achieve efficient dissociation, while keeping investment costs low. To measure conversion efficiency, a detection method is required for CO, which can be achieved using TALIF. In contrast to …

    eindhoven Repository record for A spectroscopic study on the detection of carbon monoxide for solar fuel production (opens in a new tab)

  5. Measurements of neutral particles and simulations of plasma-neutral dynamics in the HIT-SI3 experiment

    … absorption laser induced fluorescence (TALIF) diagnostic system measured monatomic, ground state deuterium neutral densities and temperatures in HIT-SI3 spheromak plasmas. These data were compared to dynamic plasma-neutral simulations performed with the PSI-Tet code. The plasma-neutral …

    washington Repository record for Measurements of neutral particles and simulations of plasma-neutral dynamics in the HIT-SI3 experiment (opens in a new tab)

  6. Two-Photon Absorption Laser Induced Fluorescence Measurements of Neutral Density in Helicon Plasma

    … absorption laser induced fluorescence (TALIF), capable of making direct ground state measurement is developed. A high intensity (5 MW/cm2), narrow bandwidth (0.1 cm -1) laser is used to directly probe the ground state of neutral hydrogen, deuterium and krypton. The diagnostic represents …

    wvu Repository record for Two-Photon Absorption Laser Induced Fluorescence Measurements of Neutral Density in Helicon Plasma (opens in a new tab)

  7. Atomic Hydrogen Dynamics and Neutral Depletion in a High Power Linear Plasma Device

    … absorption laser-induced fluorescence (TALIF) diagnostic is established to investigate the properties of neutral atomic hydrogen in a high density pulsed plasma. A Nd:YAG-pumped dye laser at 205.1nm is used to directly probe the ground state of atomic hydrogen, by monitoring the …

    anu Repository record for Atomic Hydrogen Dynamics and Neutral Depletion in a High Power Linear Plasma Device (opens in a new tab)

  8. Spatial and Temporal Mapping of Atomic Species at the Plasma-Liquid Interface

    … ab-sorption laser induced fluorescence (fs TALIF) for planar imaging of reactive atomic species in atmospheric pressure plasma jets and plasma water interaction geometries. Strong gradients in composition and temperature produce spatially varying collisional quenching and background emission …

    tamu Repository record for Spatial and Temporal Mapping of Atomic Species at the Plasma-Liquid Interface (opens in a new tab) Embargoed until 2028-05-01

  9. Spatial and Temporal Mapping of Atomic Species at the Plasma-Liquid Interface

    … ab-sorption laser induced fluorescence (fs TALIF) for planar imaging of reactive atomic species in atmospheric pressure plasma jets and plasma water interaction geometries. Strong gradients in composition and temperature produce spatially varying collisional quenching and background emission …

    tamu Repository record for Spatial and Temporal Mapping of Atomic Species at the Plasma-Liquid Interface (opens in a new tab) Embargoed until 2028-05-01

  10. Spatial and Temporal Mapping of Atomic Species at the Plasma-Liquid Interface

    … ab-sorption laser induced fluorescence (fs TALIF) for planar imaging of reactive atomic species in atmospheric pressure plasma jets and plasma water interaction geometries. Strong gradients in composition and temperature produce spatially varying collisional quenching and background emission …

    tamu Repository record for Spatial and Temporal Mapping of Atomic Species at the Plasma-Liquid Interface (opens in a new tab) Embargoed until 2028-05-01

  11. Diagnostic par spectroscopie d'émission et par TALIF de post décharge micro-ondes en flux à pression réduite de diazote et de mélanges binaires de diazote avec l'argon, l'hélium et le dihydrogène

    … (fluorescence à deux photons induite par laser TALIF). Le premier chapitre du manuscrit expose quelques généralités concernant les différents moyens de génération des décharges électriques dans les gaz, présente les distributions énergétiques des différentes espèces chimiques contenues dans les …

    star-france Repository record for Diagnostic par spectroscopie d'émission et par TALIF de post décharge micro-ondes en flux à pression réduite de diazote et de mélanges binaires de diazote avec l'argon, l'hélium et le dihydrogène (opens in a new tab)

  12. Single and Multi-photon Laser Induced Fluorescence for Electric Thruster and Fusion Applications

    … absorption laser induced fluorescence (TALIF) are used to investigate electric propulsion and fusion-relevant plasmas, respectively. Ion velocity distribution functions (IVDF) of singly ionized atomic iodine (I II) are measured for the first time and lineshape characteristics are …

    wvu Repository record for Single and Multi-photon Laser Induced Fluorescence for Electric Thruster and Fusion Applications (opens in a new tab)

  13. Kinetics of Low-Temperature Fuel Oxidation and Ignition by Repetitively Pulsed Nonequilibrium Plasmas

    … Photon Absorption Laser Induced Fluorescence (TALIF) measurements, with Xenon calibration, give the absolute O atom concentration in a variety of mixtures. Finally, the sensitivity of a plasma chemistry kinetic model has been studied and gives insight into the chemical processes that are …

    ohiolink Repository record for Kinetics of Low-Temperature Fuel Oxidation and Ignition by Repetitively Pulsed Nonequilibrium Plasmas (opens in a new tab)

  14. Atomic Oxygen Densities in Pulsed Inductively Coupled Plasmas: Laser Spectroscopy and Energy Resolved Actinometry

    … Absorption Laser Induced Fluorescence (TALIF) spectroscopy can accurately measure atomic densities with high spatial and temporal resolution, implementing it as a routine industrial method is challenging. As such, this thesis was motivated by the need to develop compatible diagnostics …

    whiterose Repository record for Atomic Oxygen Densities in Pulsed Inductively Coupled Plasmas: Laser Spectroscopy and Energy Resolved Actinometry (opens in a new tab)

  15. Barium sensing in hollow cathode plasma using cavity ring-down spectroscopy (CRDS)

    … Absorption Laser Induced Fluorescence (TALIF) technique and apply it to a BaO HC plasma. We utilize a dye laser at 212.6 nm to excite TALIF fluorescence within the plume, with the fluorescence detected at 758.7 nm. We present spatial maps for krypton neutral densities at a cathode flow …

    colostate Repository record for Barium sensing in hollow cathode plasma using cavity ring-down spectroscopy (CRDS) (opens in a new tab)

  16. Experimental investigation of a low pressure capacitively-coupled discharge

    … two-photon laser-induced fluorescence (TALIF), appearance potential mass spectrometry (APMS), Langmuir and hairpin probes. The behaviour of atomic oxygen density in mixtures of O2/SF6 was investigated using TALIF and a Langmuir probe. A significant five-fold increase of [O] was observed …

    dcu Repository record for Experimental investigation of a low pressure capacitively-coupled discharge (opens in a new tab)

Page 1 of 3