Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"Tanδ"”.
-
Dielectrics for High Temperature Capacitors Applications
… 120 to 450 ºC, and low dielectric loss tangent, tanδ ≤ 0.02, over the slightly narrower temperature range, 150 to 360 ºC. Thus an upper operating temperature > 300°C was demonstrated but without also achieving sub-zero temperature capability. Similarly, the system (1–x)[0.85Na0.5Bi0.5TiO3 – …
-
Investigating Ferroelastic and Piezoelectric Vibration Damping Behavior in Nickel-Barium Titanate and Nickel-PZT Composites
… (0.1Hz-10Hz) damping capacity of BaTiO3, tanδ has been measured in three-point bend configuration on a dynamic mechanical analyzer. Tanδ has been found to increase with temperature up to the Curie temperature (Tc) of BaTiO3, after which there was a drop in damping capacity values due to …
-
MICROWAVE AND MILLIMETER-WAVE PERMITTIVITIES OF LOW-LOSS, HIGH-THERMAL-CONDUCTIVITY, AND WIDE-BANDGAP MATERIALS SUCH AS SIC, ALN, AND DIAMOND
… εR is constant at 7.805 ± 0.007, while the tanδ increases linearly with frequency on the order of 10-4, remaining below that of fused silica. A 93-mm-diameter AlN wafer confirms scalability and reproducibility. For single-crystal diamond (≥ 1″), the εR is frequency-independent, while the …
-
Damping and Mechanical Behavior of Multiwalled Carbon Nanotube Epoxy Composites
… the macro-scale, DMA can measure damping factor (tanδ) for viscoelastic solids and glass transition temperature (Tg) can be readily determined from temperature-dependent tanδ ï€ measurements. This thesis attempts to find correlations between nanoindentation creep and impact tests to the macroscale …
-
Lead-free Dielectric and Piezoelectric Ceramics
… stability, ɛr = 800±15% from 40-550 ºC, with tanδ ≤ 0.02 over the temperature range 100-400 ºC. For a slightly higher BMT content, the dielectric properties were superior to 0.5BMT, with ɛr = 950±15% from 70 to 600 ºC and tanδ ≤ 0.02 from 160-550 ºC. Achieving temperature-stability down to -55 …
-
Modelling, characterization and development of new magnetorheological elastomers with enhanced vibration control performance
… while MR effect of tangent of loss angle tanδ is higher in inclined isolator than pure compression. For the inclined test, the highest MR effect of 48% for K’ and 68% for K’’, is observed for the pure anisotropic sample and the lowest of 26% and 30% respectively for the isotropic MRE. …
-
FINITE ELEMENT MODELING OF LIQUID CRYSTAL ELASTOMER EARPLUGS FOR HEARING PROTECTION
… elasticity and high mechanical loss factors (tanδ approaching unity across the audio frequency range), properties that distinguish them fundamentally from conventional earplug materials. The primary contribution is a finite element analysis (FEA) framework in COMSOL Multiphysics to predict the …
-
Dynamics and thermodynamics of small molecule glass formers, polymers and organic crystals
… of relaxation spectrum H(τ) and loss tangent (tanδ) for glass formers. In the dynamic mechanical measurements in the glass-rubber transition zone of polyisobutylene (PIB), an additional shoulder beside the major shoulder was observed in the relaxation spectrum H(τ) and loss tangent (tanδ). We …
-
Chitosan Edible Films Crosslinked by Citric Acid
… produced data that supports the notion that the tanδ relaxation peak of neat films near 165 °C is ascribable to structural relaxation caused by the acid present in the film, and is not a typical glass-rubber transition as it is often described in the literature. The tanδ relaxation peak …
-
Σύνθεση και μελέτη υβριδικών υγρών νανοδιηλεκτρικών για εφαρμογές σε υψηλές τάσεις
… dielectric losses (decreased dissipation factor- tanδ) and very high endurance during discharge stressing. The developed nanofluid is studied and compared with a similar system containing commercial iron oxide nanoparticles, the latter demonstrating extensive sedimentation. Herein, the dielectric …
-
Dynamic properties of nanoparticle magnetic systems
… transfer, which can be quantified by use of the tanδ loss parameter and the energy density heat loss.
-
Carbon Hybrid Materials for Electromagnetic Interference (EMI) Shielding and Charge Storage Applications
… (solution casting at10.0 wt% MXene: ε^'=370.5 ,tanδ=0.11 and VAF at10.0 wt% MXene: ε^'=3165.8 ,tanδ=0.1) were fabricated. The reported dielectric constants in this study are the highest values obtained with low dielectric losses for polymer nanocomposites in X-band frequency.
-
Espectroscopia de impedância elétrica do sistema epóxi : 1,4-butanodiol diglicidil éter/anidrido do ácido cis-1,2-ciclohexanodicarboxílico e trietilamina como iniciador
… permissividade, módulo elétrico, impedância, tanδ e admitância. Picos de relaxação foram observados somente nos diagramas de impedância imaginária (Z”) e módulo elétrico (M”) como função do logaritmo da freqüência. As frequências de relaxação obtidas por Z” e M” são distintas, devido ao fato …
-
Πειραματική μελέτη της επίδρασης των διεπιφανειών στη συμπεριφορά στερεών μονώσεων του εξοπλισμού δικτύων υψηλής τάσης
… AC voltage, experiments for measuring of the tanδ, capacitance and PD in a range of values of AC voltage from 5% up to 85% of the breakdown voltage of the specimens. Experiments were also executed for measuring the treeing inception time in PMMA specimens during electric stressing with a …
-
Crosslinkable Poly(vinyl acetate) Emulsion with Core-shell Structure for Wood Adhesive
… and the curing agent Anquamine 419. Reducing tanδ values and broader tanδ peaks indicated formation of crosslinks. It was observed that crosslinking increased the glass transition temperatures and the storage modulus in rubbery plateau region indicating the improvement of creep and heat …
-
Effect of alternative crosslinking agents on the thermo-rheological properties of SBS-modified asphalts
… by the local minimum on the master curves of tanδ(ω) suggested exceptional resistance of modified asphalts crosslinked by sulfur and sulfur-based crosslinkers to deformation. The development and strength of polymer network were evaluated by the presence of viscosity overshoots and stress …
-
Fabrication And Damping Behavior Of Particulate BaTiO3 Ceramic Reinforced Copper Matrix Composites
… analysis (DMA). The relative damping capacities (tanδ) in the composites were higher than the unreinforced metal. The damping capacity of composites D1 and D2 was also found to be dependent on temperature. Damping capacity was high from room temperature up to the Curie point of barium titanate, …
-
Investigating Human Cell Influence on the Micromechanical Environment of a 3D-Printed Bone Tissue Model
… modulus, loss modulus, and damping coefficient (tanδ). SEM was used to evaluate cell adhesion, mineral deposition, and scaffold degradation, while μCT characterized porosity, strut thickness, and trabecular separation after long-term culture. To assess the metastatic influence of breast cancer …
-
Μελέτη της ιοντικής αγωγιμότητας στερεών ηλεκτρολυτών
… From the study of the dielectric loss (tanδ) versus frequency plots at different temperatures, the presence of dielectric relaxation was suggested in all the compounds.
-
Manufacture of Low Fat Process Cheese with Improved Functional Properties and Manufacture of Full Fat, Reduced Fat and Low Fat Process Cheese with 50% Reduced Sodium
… (G'), viscous modulus (G") and temperature at Tanδ = l were determined using dynamic stress rheometry (DSR). The hardness of the samples was determined with texture profile analysis (TP A). The elastic (G') and viscous (G") moduli results obtained with DSR showed a significant difference …
Page 1 of 2