Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 47 for “"Tandem accelerator"”.
-
An Embedded Temporal Expert for Control of a Tandem Accelerator
… the terminal charging subsystem of a model FN Tandem particle accelerator: a problem which is resistant to an analytic solution. Using the expert system, cooperating 68HC16 microprocessors have successfully operated the accelerator, performing as well, or better than an experienced human …
-
Design of a negative helium ion injection system for the 6MV en tandem accelerator at iThemba laboratory for accelerator based sciences
… of alpha particles is of great interest in tandem electrostatic accelerator facilities. The Tandem accelerator at iThemba LABS makes use of an 860A Cs-Sputtering negative ion source. This particular procedure assisted by sputtering is totally ineffective for atoms of the inert gasses such as …
-
Investigation of electron capture in swift C4+ (1s2s 3S) collisions with gas targets using a zero-degree Auger projectile spectroscopy apparatus built with the L45 beam line at the ‘Demokritos’ 5.5MV tandem accelerator
… with the 1s2 ground state ions as provided by accelerators. One of the main interests in the aforementioned process has to do with the question of whether the similarly configured 1s2s2p 4P and 2P± states are populated in the collision according to spin statistics, i.e. in the ratio R of their …
-
The McMaster Polarized Ion Source
… of such as source for the McMaster University Tandem Accelerator is described. Finally, measurements and calibrations of the operating parameters are presented.</p>
-
Charge State Dependence of M-Shell X-Ray Production in 67Ho by 2-12 MeV Carbon Ions
… The experiment was performed using an NEC 9SDH-2 tandem accelerator at the Ion Beam Modification and Analysis Laboratory of the University of North Texas. The high charge state carbon ions were produced by a post-accelerator stripping gas cell. Ultra-clean holmium targets were used in ion-atom …
-
Measurements of scintillation light quenching for protons in rare-earth inorganic scintillators
… proton energies from 1-25 MeV range using a 3 MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)4He. Using a variation of the Birks formula, I extracted the Birks’ parameter to understand the nonproportional lightoutput response of these materials as a function of temperature and …
-
Search for the decays of 113Ba
… carried out in Japan Atomic Energy Agency (JAEA) tandem accelerator in Tokai, Japan. This work aimed to discover barium-113 produced via the fusion-evaporation reaction nickel-58(nickel-58,3n)barium-113 and observation through its alpha-decay chain from barium-113 to xenon-109 to tellurium-105 and …
-
Spektroskopie der Oktupolkorrelationen von 231Pa und 229Pa mit adaptierten Koinzidenzteilchendetektorsystemen
… MeV p,t)229Pa at the Munich Universities tandem accelerator laboratory gave experimental clues of the 229Pa ground-state energy. A detailed study of231Pa by Coulomb-excitation with 148 MeV 32S und 255, 260, 261 MeV 58Ni projectiles can answer open questions on octupole correlations and …
-
Identification of Nilsson Orbitals in the Superdeformed Minimum of 237Pu
… (Ealpha =24 MeV, Deltat=400 ns) from the Cologne Tandem accelerator. A metallic 235U target (3.7 mg/cm2)was used, where the 237Pu reaction products were stopped and fission products were emitted in opposite directions. The rare gamma-rays from the second potential well in delayed coincidence with …
-
HiSPANoS (HiSPAlis Neutron Source) at CNA: installation and commissioning of the rst neutron time of ight beamline in Spain
… the beam in a new dedicated neutron line of the Tandem Accelerator at CNA. The goal of this project was the first measurement of the 7Li(p,n)7Be (Ep = 1912 keV) angular-energy neutron field at the implemented HiSPANoS time-of-fight facility at CNA from 2:5 to 130 keV. The measurement has been …
-
Recoil-energy measurements of slow highly-charged ions produced by synchrotron radiation and by swift-ion impact
… ions produced by swift-ion impact using the EN Tandem accelerator at Oak Ridge National Laboratory. Average energies for the higher charge states were found to be up to 2 orders of magnitude larger than for those produced by photoionization. Impact parameters important in the collision processes …
-
Transmission electron microscopy investigation of ion implantation damage in gallium arsenide and other semiconductors
… included those performed in situ using the HVEM-Tandem Accelerator Facility at Argonne National Laboratory and also those performed using high-resolution TEM. The implantations were made with Ar$\sp+$, Kr$\sp+$, Xe$\sp+$, and Au$\sp+$ ions (energy 50 or 80 keV) at 30 and 300 K. The …
-
Fusion Reaction Cross-section Measurements near <sup>100</sup>Sn
… at Oak Ridge National Laboratory using the 25 MV Tandem Accelerator and Recoil Mass Spectrometer. This work can be used in planning of future experiments on exotic isotopes near <sup>100</sup>Sn. Results for the production of <sup>109</sup>Sb were found to agree fairly well with HIVAP prediction, …
-
On the spectrometry of laser-accelerated particle bunches and laser-driven proton radiography
… from electrostatic or radio-frequency driven accelerators. Among these characteristics are high beam intensities (∼ 10^9 protons/ns), a broad energy distribution (∼ 100%) and a strong electromagnetic pulse generated in the laser-plasma interaction. Due to these peculiar properties, …
-
An investigation of radiative lifetimes and oscillator strengths for allowed intra L-shell transitions in multiply-charged chlorine ions
… produced by the Oak Ridge 2 National Laboratory tandem accelerator were directed through 5 µg/cm carbon excitor foils. The foil-excited EUV beam radiation was dispersed and detected with a 2.2 m grazing incidence spectrometer. Lifetimes have been converted to oscillator strengths (f-values) for …
-
PROTON IRRADIATION SAMPLE HOLDER II (PISH II)
… as the evolution of new nuclear reactors. The tandem accelerator in RMTL is used to simulate the radiation damage and changes to materials occurring in a nuclear reactor. Previously, it used the sample holder known as PISH I to hold samples during proton or alpha particle irradiation. The …
-
A Study of the Astrophysically Important States of 31S via the 32S(d,t)31S Reaction
… single-nucleon transfer reaction using the MP tandem accelerator and Q3D magnetic spectrograph at MLL in Munich, Germany. Excited states of <sup>31</sup>S in the 6-7 MeV region were observed and spin-parity constraints have been suggested. In this work we describe the experimental setup, data …
-
A Radio Frequency Quadrupole Instrument for use with Accelerator Mass Spectrometry: Application to Low Kinetic Energy Reactive Isobar Suppression and Gas–phase Anion Reaction Studies
… for Anions (ISA), has been integrated into an Accelerator Mass Spectrometry (AMS) system to facilitate anion–gas reactions before the tandem accelerator. An AMS Cs+ sputter source provided > 15 keV ions that were decelerated in the prototype ISA to < 20 eV for reaction in a single collision …
-
Pb-Pb Isotopic and X-ray Tomographic Constraints on the Origin of Chondrules
… using LaF−4 to suppress the 137Ba isobar during tandem accelerator mass spectrometry combined with a novel instrumental technique for isobar separation.
-
Fluorine-18 Production for PET and an Investigation of the Fluorine-18(p,alpha)Oxygen-15 Reaction with a Radioactive Beam
… An ^{18}F ion beam was generated by a dual-accelerator method incorporating off-line chemical separation. ^ {18}F was produced on the UW radioisotope production cyclotron, then delivered to Argonne National Laboratory (ANL) for beam formation on the tandem accelerator on ATLAS. An average …
Page 1 of 3