  1. On Moving Contacts in On-Load Tap Changers

    … life test for the moving contacts in on-load tap changers, simulating the wear of 30 years use regarding oxidation and coking. The secondary topic is to examine the surface structure of silver contacts to aid in understanding how silver iodide contacts can have the superb electrical properties …

    chalmers Repository record for On Moving Contacts in On-Load Tap Changers (opens in a new tab)

  2. Optimal control for on-load tap-changers and inverters in photovoltaic plants applying teaching learning based optimization

    … neglect the coordinated operation of On-Load Tap-Changers (OLTCs), mechanical aging effects, and inverter operating constraints, resulting in suboptimal performance under dynamic operating conditions. This doctoral research develops and experimentally validates an optimized EMS based on an …

    cadiz Repository record for Optimal control for on-load tap-changers and inverters in photovoltaic plants applying teaching learning based optimization (opens in a new tab)

  3. Dielectric Evaluation of Tap-changer

    Abstract Tap-changers are electro-mechanical devises typically inbuilt into power transformers used for voltage regulations in power systems. They operate under extreme electrical stresses and must be reliable to ensure un-interrupted power flow and voltage stability in the power system. Thus, …

    chalmers Repository record for Dielectric Evaluation of Tap-changer (opens in a new tab)

  4. Investigation of long-time stability of electrical contacts

    … power supply. To meet with such load variations, tap-changers are used in transformers which help in the regulation of the output voltage to the required levels. There are different kinds of tap-changers used depending on ratings as well as applications. These tap-changers operate by selecting …

    chalmers Repository record for Investigation of long-time stability of electrical contacts (opens in a new tab)

  5. Evaluation of Single Phase Smart PV Inverter Functions in Unbalanced Residential Distribution Systems

    … capacitor banks, voltage regulators and on load tap changers. These increases can lead to excess wear and tear on the devices causing power utilities to perform unwanted replacement and maintenance. However, smart PV inverters when controlled under specific functions can enable these inverters to …

    arkansas Repository record for Evaluation of Single Phase Smart PV Inverter Functions in Unbalanced Residential Distribution Systems (opens in a new tab)

  6. Improving power system voltage regulation: a capacitive ladder-based power electronic AC voltage regulator

    … which is a substitute for an electromechanical tap changer in power transformers. The proposed CL-EVR employs a combination of capacitors and TRIACs to generate voltage steps that can be added or subtracted from the grid voltage to achieve voltage regulation. In comparison to traditional on-load …

    manitoba Repository record for Improving power system voltage regulation: a capacitive ladder-based power electronic AC voltage regulator (opens in a new tab)

  7. Analysis and control of voltage dynamics in electric power systems

    … load voltage controls, such as ULTC (under load tap changers), is investigated. A detailed reduced-order machine dynamical model is proposed for more reliable study of voltage-related problems. The main contribution of the analytical work is in recognizing voltage problems as unacceptable …

    uiuc Repository record for Analysis and control of voltage dynamics in electric power systems (opens in a new tab)

  8. Comparação de dois métodos de detecção da instabilidade de tensão baseados em medição fasorial e equivalente de Thévenin

    … limiters (OELs), actuation of on load tap changers (OLTCs), systemic contingency and limitation of active generation (turbine limits). The simulations were performed in two systems: 3-Bus System and WSCC 9-Bus System. The simulation is performed in the time domain, using the power …

    brazil-uerj Repository record for Comparação de dois métodos de detecção da instabilidade de tensão baseados em medição fasorial e equivalente de Thévenin (opens in a new tab)

  9. ΣΥΜΒΟΛΗ ΤΗΣ ΠΙΘΑΝΟΤΙΚΗΣ ΡΟΗΣ ΦΟΡΤΙΟΥ ΣΤΟΝ ΕΛΕΓΧΟ ΛΕΙΤΟΥΡΓΙΑΣ ΤΩΝ ΣΥΣΤΗΜΑΤΩΝ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ

    … AS FOR DETERMINING CONSTANT SETTINGS FOR LOAD TAP CHANGERS, VOLTAGE REGULATORS AND SWITCHED CAPACITORS IN DISTRIBUTION NETWORKS BASED ON THE DIFFERENT RESPONSE TIMES OF THE CONTROL DEVICES. IN ADDITION, APPLICATIONS OF THE METHOD IN SYSTEMS INCLUDING WINDGENERATORS ARE PRESENTED, IN ORDER TO …

    greece Repository record for ΣΥΜΒΟΛΗ ΤΗΣ ΠΙΘΑΝΟΤΙΚΗΣ ΡΟΗΣ ΦΟΡΤΙΟΥ ΣΤΟΝ ΕΛΕΓΧΟ ΛΕΙΤΟΥΡΓΙΑΣ ΤΩΝ ΣΥΣΤΗΜΑΤΩΝ ΗΛΕΚΤΡΙΚΗΣ ΕΝΕΡΓΕΙΑΣ (opens in a new tab)

  10. Voltage stability and distance protection zone3

    … by 47% during the pre-fault condition when tap changers are blocked and raised to 52% when tap changers are in operation. It was observed that zone3 distance relay operation should not be entirely blamed for the cascaded trippings because even when zone3 and zone1 were blocked, the voltage …

    chalmers Repository record for Voltage stability and distance protection zone3 (opens in a new tab)

  11. False data injection attacks with incomplete information

    … of circuit breaker switches and transformer tap changers and also because of the attacker's limited physical access to most grid facilities. In this thesis, we have shown the minimum required information for a perfect false data injection attack. Then, we mathematically characterize false …

    ttu Repository record for False data injection attacks with incomplete information (opens in a new tab)

  12. Planning and operation of active smart grids

    … switches, energy storage units, under load tap changers, and shunt capacitors is investigated in the presented VVO methodology. The proposed methodologies in this thesis have been tested on sample distribution systems and their effectiveness is validated using real data of smart meters and …

    ubc Repository record for Planning and operation of active smart grids (opens in a new tab) Download PDF for Planning and operation of active smart grids (opens in a new tab)

  13. An Integrated Voltage Optimization Approach For Industrial Loads

    … substation and the switching operations of Load Tap Changers (LTC). The proposed VO framework is tested on load models developed using simulated and real data. Results suggest that the proposed technique can be successfully implemented by industrial customers or plant operators to improve their …

    waterloo Repository record for An Integrated Voltage Optimization Approach For Industrial Loads (opens in a new tab)

  14. Unbalanced power systems resolution including power and frequency regulation

    … buses can be regulated through the operation of tap changers installed on threephase and single-phase transformers. The implementation code is discussed in detail. High computation speeds could be reached by devising several array-based procedures, among other measures. A number of numerical …

    ets-quebec Download PDF for Unbalanced power systems resolution including power and frequency regulation (opens in a new tab)

  15. Voltage and Var Control and Real-Time Digital Simulator-Based Protection System Testing for Power Distribution Systems

    … Conventional mechanical devices such as on-load tap changers (OLTCs) and capacitor banks (CBs) would require frequent switching to mitigate these fluctuations, increasing operational and maintenance costs. Smart inverter functions within IBRs offer a more flexible means of voltage control. …

    uky-thes Repository record for Voltage and Var Control and Real-Time Digital Simulator-Based Protection System Testing for Power Distribution Systems (opens in a new tab)

  16. Supervisory voltage control scheme for grid-connected wind farms

    … of additional compensating devices (transformer tap changers, switched-capacitors, SVCs, etc.) to meet local power quality conditions. This thesis proposes a supervisory control scheme that uses the individual wind turbines to regulate voltage at the required location, i.e., point of common …

    ubc Repository record for Supervisory voltage control scheme for grid-connected wind farms (opens in a new tab) Download PDF for Supervisory voltage control scheme for grid-connected wind farms (opens in a new tab)

  17. Optimization and control of voltage in active distribution networks

    … networks. While traditional devices like On-Load Tap Changers (OLTCs) provide a foundational means of voltage control, they lack the speed and flexibility to manage the spatial and temporal variations introduced by high DER penetration. This thesis addresses these challenges by proposing and …

    glasgow Repository record for Optimization and control of voltage in active distribution networks (opens in a new tab) Download PDF for Optimization and control of voltage in active distribution networks (opens in a new tab)

  18. Data-driven coordination of assets in power distribution systems for ancillary service provision

    … to address the problem of coordinating load tap changers (LTCs)---an important class of assets used for voltage control in distribution networks---using only measurements of voltage magnitudes. Different from the ODCP that is cast as a static optimization problem, the optimal LTC coordination …

    uiuc Repository record for Data-driven coordination of assets in power distribution systems for ancillary service provision (opens in a new tab)

  19. Operational voltage control of future distribution networks

    … for control equipment such as voltage targets or tap changers of under-load tap changing (ULTC) transformers and switching status of shunt capacitors. These settings are normally determined by operators in control rooms and are changed on the condition that power supply cannot be adequately …

    strathclyde Repository record for Operational voltage control of future distribution networks (opens in a new tab)

  20. Optimization approach for online identification of harmonic resonance due to pending Volt/VAr operation, An

    … support equipment, such as transformer load tap changers, voltage regulators, and capacitor banks. The majority of these algorithms utilize metaheuristic programming methods to determine the Volt/VAr scheme that produces the most energy efficient operating conditions. It has been well …

    colo-mines Repository record for Optimization approach for online identification of harmonic resonance due to pending Volt/VAr operation, An (opens in a new tab)