Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"Target Volume Delineation"”

  1. Target Volume Delineation in Dynamic Positron Emission Tomography Based on Time Activity Curve Differences

    Tumor volume delineation plays a critical role in radiation treatment planning and simulation, since inaccurately defined treatment volumes may lead to the overdosing of normal surrounding structures and potentially missing the cancerous tissue. However, the imaging modality almost exclusively used …

    alberta Repository record for Target Volume Delineation in Dynamic Positron Emission Tomography Based on Time Activity Curve Differences (opens in a new tab)

  2. Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed to mography Image Sets For Stereotactic Body Radiation Therapy

    … because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, …

    uthsc Repository record for Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed to mography Image Sets For Stereotactic Body Radiation Therapy (opens in a new tab)

  3. Neoadjuvant Stereotactic Ablative Radiotherapy To Treat Early Stage Breast Cancer Patients: The Role Of DCE-MRI

    … dynamic contrast-enhanced (DCE)-MRI to guide target volume delineation. A subset also received post-SABR DCE-MRI to facilitate response assessment. Recent safety concerns of long-term retention of gadolinium-based contrast agents (GBCA) in brain and bone led us to reduce the dose of GBCA to …

    uwo Repository record for Neoadjuvant Stereotactic Ablative Radiotherapy To Treat Early Stage Breast Cancer Patients: The Role Of DCE-MRI (opens in a new tab)

  4. Precision oncology: automated segmentation of breast MRI

    … aimed at enhancing the consistency of target volume delineation while addressing inter-observer variability and the labour demands associated with manual workflows in clinical radiotherapy settings. The proposed model was trained on a high-resolution 3D MRI dataset, employing advanced …

    uws Repository record for Precision oncology: automated segmentation of breast MRI (opens in a new tab)

  5. Towards MRI guided radiotherapy for lung cancer

    … a free-breathing protocol was developed to aid target volume delineation and overcome challenges with breath-hold non-compliance. An assessment of a radiologist-led workshop on inter-observer variability in volume delineation showed no significant improvement. To assess the potential benefit of …

    unsw Repository record for Towards MRI guided radiotherapy for lung cancer (opens in a new tab)

  6. A comparison of open source deep learning based models for automatic tumor segmentation in radiotherapy planning of glioblastoma multiforme adult patients

    … with temozolomide. In RT planning, general target volume is defined by an expert radiologist using contrast-enhanced T1-weighted (T1-ce) MR images to locate residual enhancing tumor and T2-FLAIR to extend contours on visible perifocal edema. Procedure requires strong knowledge and consumes …

    catalunya Repository record for A comparison of open source deep learning based models for automatic tumor segmentation in radiotherapy planning of glioblastoma multiforme adult patients (opens in a new tab)

  7. Optimized scanning procedures for 4D CT data acquisition in radiation therapy

    … local tumor control through dose escalation to target volumes while at the same time sparing surrounding healthy tissue. Accurate target volume delineation is essential in achieving this goal to avoid inadequate tumor coverage and/or irradiation of an unnecessary volume of healthy tissue. …

    mcgill Repository record for Optimized scanning procedures for 4D CT data acquisition in radiation therapy (opens in a new tab)

  8. Standardisation and optimisation of radical radiotherapy for cervical cancer

    … known uncertainties in radiotherapy planning; target volume delineation. Having quantified the variation in comparison to a gold standard I investigated the dosimetric impact of the observed variation. I also produced a step-by-step pictorial delineation atlas, having reviewed all available …

    ucl Repository record for Standardisation and optimisation of radical radiotherapy for cervical cancer (opens in a new tab)

  9. Auto-Delineation of Oropharyngeal Clinical Target Volumes Using Deep Learning Techniques

    … radiation dose to the defined treatment targets achieving more accurate target dose distribution and better sparing of normal tissues. However, producing very precise treatment plans may be ineffective if the target volumes are not defined accurately. Furthermore, there are several …

    uthsc Repository record for Auto-Delineation of Oropharyngeal Clinical Target Volumes Using Deep Learning Techniques (opens in a new tab)

  10. Implementation,Validation and Application of an Automated Motion Correction Algorithm in Hepatic Perfusion CT for Image-Guided Radiotherapy

    … (DCE-CT) image series, which consisted of 40 CT volumes acquired sequentially over 2 minutes. Perfusion maps were generated from unregistered and registered DCE-CT scans and compared to determine impact of motion correction on tumour-normal tissue contrast. The motion corrected perfusion maps …

    uwo Repository record for Implementation,Validation and Application of an Automated Motion Correction Algorithm in Hepatic Perfusion CT for Image-Guided Radiotherapy (opens in a new tab)

  11. Development and Optimization of Four-dimensional Magnetic Resonance Imaging (4D-MRI) for Radiation Therapy

    … radiotherapy (RT) is to identify the treatment target accurately, following which the high-dose treatment volume may be expanded into the surrounding tissues in order to create the clinical and planning target volumes. Respiratory motion can induce errors in target volume delineation and dose …

    duke Repository record for Development and Optimization of Four-dimensional Magnetic Resonance Imaging (4D-MRI) for Radiation Therapy (opens in a new tab)

  12. CT-PET guided target delineation in head and neck cancer and implications for improved outcome

    … This thesis has investigated 18FDG CT-PET guided target volume delineation methods and attempted to validate 64Cu-ATSM as a hypoxic radio-nuclide in patients with squamous cell carcinoma of the Head and Neck. Materials and Methods: Eight patients with locally advanced disease underwent 18FDG …

    ucl Repository record for CT-PET guided target delineation in head and neck cancer and implications for improved outcome (opens in a new tab)

  13. Development of computer-based algorithms for unsupervised assessment of radiotherapy contouring

    … the advances in radiotherapy treatment delivery, target volume delineation remains one of the greatest sources of error in the radiotherapy delivery process, which can lead to poor tumour control probability and impact clinical outcome. Contouring assessments are performed to ensure high quality …

    cambridge Repository record for Development of computer-based algorithms for unsupervised assessment of radiotherapy contouring (opens in a new tab)

  14. Automated to ols for Contour Review in Radiotherapy

    Peer review of organ-at-risk and target volume delineation is essential for patient safety and optimization of treatment outcomes. Peer review makes a substantial impact on patient outcomes, reporting notable rates of plan changes when reviewed and worse survival when patient cases are not …

    uthsc Repository record for Automated to ols for Contour Review in Radiotherapy (opens in a new tab)

  15. Gross tumor volume imaging: comparison of MRI, FET-PET and perfusion MRI in patients with recurrent glioblastoma

    … radiation therapy and chemotherapy. The gross target volume (GTV) for radiotherapy may be determined with FET-PET or contrast enhanced MRI. Generally, diagnosis, treatment planning and follow-up of GBM are based on MRI, however conventional MRI has a limitation, the inability to differentiate …

    freiburg-diss Repository record for Gross tumor volume imaging: comparison of MRI, FET-PET and perfusion MRI in patients with recurrent glioblastoma (opens in a new tab)

  16. A Unified Consideration of Geometric Uncertainties in Radiation Therapy Targeting of Oesophageal Carcinoma

    … is currently achieved by enlarging the apparent target volume by various safety margins. This thesis investigated uncertainty sources relating to target position and extent in oesophageal carcinoma, both static and dynamic, and evaluated their impact in a combined model. The first were errors …

    qucosa-diss Repository record for A Unified Consideration of Geometric Uncertainties in Radiation Therapy Targeting of Oesophageal Carcinoma (opens in a new tab)