Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 34 for “"Target registration error"”.

  1. Comparing Measured and Theoretical Target Registration Error of an Optical Tracking System

    … constructing a mechanism that allows a tracked target to move with spherical motion (i.e., there exists a single point on the mechanism—the center of the sphere—that does not change position when the tracked target is moved). We imagine that the center of the sphere is the tip of a surgical tool …

    york Repository record for Comparing Measured and Theoretical Target Registration Error of an Optical Tracking System (opens in a new tab)

  2. Mathematical methods for 2D-3D cardiac image registration

    … aimed at intensity-based slice-to-volume registration, aligning a cross-sectional slice of a 3D volume to a 2D image. The approach is flexible and can accommodate various regularization schemes, similarity measures, and optimizers. We evaluate the framework by registering 2D and 3D cardiac …

    uoit Repository record for Mathematical methods for 2D-3D cardiac image registration (opens in a new tab)

  3. Registration of Three-Dimensional Cranial Ultrasound Images and Segmentations using Classical and Deep Learning Approaches

    … to each other to spatially align images. Current registration methods for this task require a manual rigid-body registration, requiring precise picking of points in each image, a technical and time-consuming procedure subject to observer variability. To this end, I developed and tested an …

    guelph Repository record for Registration of Three-Dimensional Cranial Ultrasound Images and Segmentations using Classical and Deep Learning Approaches (opens in a new tab)

  4. 4D-CT Lung Registration and its Application for Lung Radiation Therapy

    … multi-level and multi-resolution optical flow registration coupled with thin plate splines (TPS), to address registration issue of inconsistent intensity across respiratory phases. It achieves higher accuracy as compared to multi-resolution optical flow registration and other commonly used …

    ucf Repository record for 4D-CT Lung Registration and its Application for Lung Radiation Therapy (opens in a new tab)

  5. A comparison of three methods of ultrasound to computed tomography registration

    … instruments and the placement of implants. Registration (i.e. alignment) can be accomplished in many ways: by registering implanted fiducial markers, by touching a probe to the bone surface, or by aligning intraoperative two dimensional flouro images with the the three dimensional CT data. …

    queens Repository record for A comparison of three methods of ultrasound to computed tomography registration (opens in a new tab)

  6. Calibration of a Mobile-Gantry CT Scanner for Surgical Navigation

    … potentially uncertain process of intra-operative registration of the images to the patient. In a direct navigation system, such an intra-operative registration is replaced with pre-operative patient-independent calibration in a process that determines the relationship between the coordinate frame …

    queens Repository record for Calibration of a Mobile-Gantry CT Scanner for Surgical Navigation (opens in a new tab)

  7. A Novel Registration Algorithm for Intraoperative Surgical Guidance System with da Vinci Robot Platform

    … surgical outcomes are highly sensitive to the co-registration accuracy between the endoscopic camera and the TRUS frames. Based on the photoacoustic effect, this study focuses on the photoacoustic marker (PM) technique where the laser sources can be localized by the TRUS. Despite the high accuracy …

    jhu Repository record for A Novel Registration Algorithm for Intraoperative Surgical Guidance System with da Vinci Robot Platform (opens in a new tab) Embargoed until 2026-12-01

  8. A System For Computer-Assisted Surgery With Intraoperative CT Imaging

    … especially by needing neither image-to-patient registration nor a lengthy process of segmenting and generating a 3D model. In this dissertation, a method for computer-assisted surgery using direct navigation on intraoperative images is presented. In this system the registration step of a …

    queens Repository record for A System For Computer-Assisted Surgery With Intraoperative CT Imaging (opens in a new tab)

  9. Feature Based Registration of Ultrasound and CT Data of a Scaphoid

    … approach, and an Unscented Kalman Filter-based Registration (UKF). We use two different ultrasound segmentation methods; a semi-automatic segmentation, and a Bayesian segmentation technique. The segmented ultrasound data is then registered to a CT volume. The success or failure of the …

    queens Repository record for Feature Based Registration of Ultrasound and CT Data of a Scaphoid (opens in a new tab)

  10. 3D ultrasound-based patient positioning for radiotherapy

    … ultrasound-based patient positioning system for target localisation during radiotherapy is described. This system incorporates the use of optically tracked dedicated 3D ultrasound probes to acquire images of the target anatomy during both the radiotherapy simulation and treatment procedures. The …

    ubc Repository record for 3D ultrasound-based patient positioning for radiotherapy (opens in a new tab) Download PDF for 3D ultrasound-based patient positioning for radiotherapy (opens in a new tab)

  11. Reconstruction of 3D Histology Volumes from Breast Lumpectomy Specimens

    … this thesis, we hypothesize that by using image registration algorithms, 3D histology volumes can be automatically reconstructed from stacked 2D images of histology sections. We present an image registration framework for histology volume reconstruction, which is also extendable for registration …

    toronto-retro Repository record for Reconstruction of 3D Histology Volumes from Breast Lumpectomy Specimens (opens in a new tab)

  12. Three-Dimensional Medical Image Registration with Applications in Proton Therapy

    Three-dimensional deformable image registration (DIR) is an important technique in medical imaging, facilitating the alignment of images acquired from different sources or at different times for clinical diagnosis and treatment planning. In clinical proton therapy dose planning, dual-energy …

    wustl Repository record for Three-Dimensional Medical Image Registration with Applications in Proton Therapy (opens in a new tab)

  13. Linear Object Registration for Image-Guided Interventions

    Purpose: Image-guided interventions rely on registration of images, models, and surgical tools into a common navigation space. Point-set registration is commonly used to perform this registration, but requires well-defined landmark points to be present on these tools. In this thesis, a …

    queens Repository record for Linear Object Registration for Image-Guided Interventions (opens in a new tab)

  14. Über die klinische Testung eines elektromagnetischen Navigationsverfahrens und die Entwicklung verschiedener Werkzeuge für den intraoperativen Einsatz am fixierten und unfixierten Cranium

    … der Bilddatenregistrierung wurden der Fiducial Registration Error (FRE) und der Target Registration Error (TRE) erfasst. Als Maß für die Anwendungsgenauigkeit wurde der Positionsfehler (PE) gemessen, außerdem wurden Brainshift, Zielvolumen und Zieltiefe bestimmt. Die Daten wurden gesamt und nach …

    fu-berlin Repository record for Über die klinische Testung eines elektromagnetischen Navigationsverfahrens und die Entwicklung verschiedener Werkzeuge für den intraoperativen Einsatz am fixierten und unfixierten Cranium (opens in a new tab)

  15. Development of an image-guided surgical workflow and tracked surgical tools for mandibular reconstruction surgery

    … cover the aims of developing and verifying a registration protocol, developing the tracked surgical tools and testing the system on cadaver specimens. Using a combined paired-point and fiducial-model registration method we found we could achieve a Target Registration Error of 1.25 ± 0.06mm on …

    ubc Repository record for Development of an image-guided surgical workflow and tracked surgical tools for mandibular reconstruction surgery (opens in a new tab) Download PDF for Development of an image-guided surgical workflow and tracked surgical tools for mandibular reconstruction surgery (opens in a new tab)

  16. Image-Guided Robotic Dental Implantation With Natural-Root-Formed Implants

    … operations of the robot using a two-step registration procedure with the help of a Coordinate Measurement Machine (CMM). The natural-root implants mimic the root structure of natural teeth and were proved by Finite Element Method (FEM) to provide superior stress distribution than current …

    odu Repository record for Image-Guided Robotic Dental Implantation With Natural-Root-Formed Implants (opens in a new tab)

  17. VIRTUAL FLUOROSCOPY SYSTEM FOR ARTHROSCOPIC SURGICAL TRAINING

    … similar to that of a fluoroscopy system. The registration accuracy was evaluated using Root Mean Square Target Registration Error (RMS TRE). The RMS TRE for the system setup with the mechanical tracker was evaluated at 2:0 mm, 2:1 mm, and 2:5 mm, for 4, 5, and 6 control points, respectively. …

    mcmaster Repository record for VIRTUAL FLUOROSCOPY SYSTEM FOR ARTHROSCOPIC SURGICAL TRAINING (opens in a new tab)

  18. Transperineal ultrasound image guidance system for robot-assisted laparoscopic radical prostatectomy

    … frame. In dry lab experiments, calibration error was determined to be 0.84±0.49mm. Next, using a deformable finite element model-based deformable registration, annotated preoperative MRI is registered the ultrasound volume for intraoperative visualization of cancerous lesions. A virtual …

    ubc Repository record for Transperineal ultrasound image guidance system for robot-assisted laparoscopic radical prostatectomy (opens in a new tab) Download PDF for Transperineal ultrasound image guidance system for robot-assisted laparoscopic radical prostatectomy (opens in a new tab)

  19. Real-time ultrasound bone segmentation and robust US-CT registration for surgical navigation of pelvic fractures

    … X-rays. The surgery is prone to screw insertion errors, which can harm the patient. We aim to alleviate these issues by proposing ultrasound (US), instead of X-rays, to guide the surgery. However, US images are noisy, which makes them difficulty to use intraoperatively. This thesis presents …

    ubc Repository record for Real-time ultrasound bone segmentation and robust US-CT registration for surgical navigation of pelvic fractures (opens in a new tab) Download PDF for Real-time ultrasound bone segmentation and robust US-CT registration for surgical navigation of pelvic fractures (opens in a new tab)

Page 1 of 2