Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 84 for “"Target volumes"”

  1. Auto-Delineation of Oropharyngeal Clinical Target Volumes Using Deep Learning Techniques

    … radiation dose to the defined treatment targets achieving more accurate target dose distribution and better sparing of normal tissues. However, producing very precise treatment plans may be ineffective if the target volumes are not defined accurately. Furthermore, there are several …

    uthsc Repository record for Auto-Delineation of Oropharyngeal Clinical Target Volumes Using Deep Learning Techniques (opens in a new tab)

  2. Adaptation of High-Precision Radiotherapy to Moving Target Volumes in Real-Time Using Dynamic Multileaf Collimators

    … delivery of modulated fluence patterns to the target volume. Intrafractional target motion, however, considerably deteriorates the geometric accuracy of the delivery process. Therefore, a dynamic control system was developed which enabled the real-time adaptation of the dose delivery for moving …

    heid-diss Repository record for Adaptation of High-Precision Radiotherapy to Moving Target Volumes in Real-Time Using Dynamic Multileaf Collimators (opens in a new tab)

  3. Automated Segmentation And Clinical Target Volumes Definition For Nasopharyngeal Cancer Radiation Treatment Using Computed Tomography, Non New Net And Landmarks

    Purpose: Delineation of Clinical Target Volumes (CTVs) for nasopharyngeal cancer radiotherapy is inherently complex, primarily due to the variability in disease location and extent. This study introduces an auto-contouring tool developed following the NRG-HN001 protocol, demonstrating significant …

    houston Repository record for Automated Segmentation And Clinical Target Volumes Definition For Nasopharyngeal Cancer Radiation Treatment Using Computed Tomography, Non New Net And Landmarks (opens in a new tab)

  4. Evaluation of the contribution of dual-energy CT to the definition of target volumes and organs at risk in radiation oncology

    … à délimiter les organes à risques (OAR) et les volumes cibles (VC), représente une source majeure d'incertitudes en RT. Réalisée par des cliniciens, elle souffre d'une forte variabilité intra- et inter-observateurs, en partie due aux limitations du SECT. Les outils de segmentation automatique, …

    star-france Repository record for Evaluation of the contribution of dual-energy CT to the definition of target volumes and organs at risk in radiation oncology (opens in a new tab)

  5. 18F-FDOPA positron emission tomography and diffusion tensor imaging for radiation therapy of high-grade gliomas with dose painting

    … arc therapy (VMAT). First, radiation therapy target volumes obtained from five observers using ¹⁸F-FDOPA PET and MRI were compared with the location of recurrences following radiotherapy. It was demonstrated with simultaneous truth and performance level estimation that high-grade glioma …

    ubc Repository record for 18F-FDOPA positron emission tomography and diffusion tensor imaging for radiation therapy of high-grade gliomas with dose painting (opens in a new tab)

  6. Neuartige Zielvolumendefinition für die Strahlentherapie des Glioblastoma multiforme

    Background: For target delineation in Glioblastoma there are currently two major consensus guidelines being used, the one of the European Organisation for Research and Treatment of Cancer (EORTC) and the one of the Radiation Therapy Oncology Group (RTOG). The resulting target volumes are often …

    freiburg-diss Repository record for Neuartige Zielvolumendefinition für die Strahlentherapie des Glioblastoma multiforme (opens in a new tab)

  7. Machine Learning Models to automate Radiotherapy Structure Name Standardization

    … identify the various Organs-at-Risk, Planning Target Volumes and `Other' organs for monitoring present and future medications. Physicians often label anatomical structure sets in Digital Imaging and Communications in Medicine (DICOM) images with nonstandard random names. Hence, the …

    vcu Repository record for Machine Learning Models to automate Radiotherapy Structure Name Standardization (opens in a new tab)

  8. Quantification of Respiratory Motion in Positron Emission Tomography for Precise Radiation Treatment of Lung Cancer

    … significant challenge for RT is to accurately target the lesion volume while avoiding the irradiation of surrounding healthy tissue. Currently at the Juravinski Cancer Centre (JCC), treatment plans for lung cancer patients are completed using fluorodeoxyglucose positron emission tomography …

    mcmaster Repository record for Quantification of Respiratory Motion in Positron Emission Tomography for Precise Radiation Treatment of Lung Cancer (opens in a new tab)

  9. Investigation of a Monte Carlo model based dose calculation for Pd-103 low dose rate breast brachytherapy and I-125 low dose rate prostate brachytherapy

    … clinical dose-volume histogram metrics of the targets and organs at risk (OAR) for both simulations were extracted and compared across the two patient cohorts. Results: Breast target volumes showed a slight overestimation of dose by water-equivalent MC of 1% for the CTV V₁₀₀ and 6% for the ETV …

    ubc Repository record for Investigation of a Monte Carlo model based dose calculation for Pd-103 low dose rate breast brachytherapy and I-125 low dose rate prostate brachytherapy (opens in a new tab)

  10. Improvements In Four-Dimensional and Dual Energy Computed to mography

    … In clinical 4D CT, semi-automatically drawn target volumes and artifacts were compared between data driven and standard 4D CT images. Target volumes were shown to be statistically at least as large as standard contours, and artifacts were significantly reduced using the data driven technique. …

    uthsc Repository record for Improvements In Four-Dimensional and Dual Energy Computed to mography (opens in a new tab)

  11. Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct

    … respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information …

    uthsc Repository record for Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct (opens in a new tab)

  12. The role of magnetic resonance imaging (MRI) in external beam radiotherapy treatment planning (RTP) for cervical cancer

    Background Accurate delineation of treatment volumes for radiotherapy is a crucial step in radiation treatment, but can be associated with considerable uncertainty and variability. Magnetic resonance imaging (MRI) has a proven benefit in the staging of cervical cancer and for image guided adaptive …

    unsw Repository record for The role of magnetic resonance imaging (MRI) in external beam radiotherapy treatment planning (RTP) for cervical cancer (opens in a new tab)

  13. CT-PET guided target delineation in head and neck cancer and implications for improved outcome

    … This thesis has investigated 18FDG CT-PET guided target volume delineation methods and attempted to validate 64Cu-ATSM as a hypoxic radio-nuclide in patients with squamous cell carcinoma of the Head and Neck. Materials and Methods: Eight patients with locally advanced disease underwent 18FDG …

    ucl Repository record for CT-PET guided target delineation in head and neck cancer and implications for improved outcome (opens in a new tab)

  14. Advanced magnetic resonance imaging of radiation-induced normal and abnormal brain tissue changes

    … brain tumours. Inevitably, the location of the target volumes, the resulting differences in radiation directions and positioning inaccuracies during treatment result in a certain amount of radiation dose being delivered to the surrounding normal tissue. Exposure of normal tissue to radiation can …

    qucosa-diss Repository record for Advanced magnetic resonance imaging of radiation-induced normal and abnormal brain tissue changes (opens in a new tab)

  15. An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant

    … restricted to or permitted outside of spherical target volumes. To address more realistic geometries, model parameters were used to re-plan a 5-patient cohort in MIM Symphony. The results confirm that the current clinical needle-to-needle and seed-to-seed spacing provides the most favourable dose …

    calgary Repository record for An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant (opens in a new tab)

  16. Two-step-fusion 18F-fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) based radiotherapy in locally advanced oropharyngeal cancer

    … ratio) of bony structures. Radiotherapy target volumes for both primary (T) and nodal disease (N) were defined separately on CTsim and FDG-PET/CT using visual assessment (PET/CT-vis) and segmentation with 50% SUVmax (PET/CT-50%). Volumes (cc) and spatial reproducibility (R) were …

    glasgow Repository record for Two-step-fusion 18F-fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) based radiotherapy in locally advanced oropharyngeal cancer (opens in a new tab)

  17. Optimization of Radiation Therapy Treatment Planning Considering Setup Uncertainty and Radiobiological Effects

    … effectiveness of protons, high LETs in target volumes and low LETs in critical structures and normal tissues are preferred in an IMPT plan. Conventionally, the IMPT optimization criteria only includes dose-based objectives in which the relative biological effectiveness (RBE) is assumed …

    houston Repository record for Optimization of Radiation Therapy Treatment Planning Considering Setup Uncertainty and Radiobiological Effects (opens in a new tab)

  18. Use of ¹⁸F-BPA PET images and image registration to enhance radiation treatment planning for boron neutron capture therapy

    … linearly and homogenously within the tumor and target volumes. Current methods should be improved. The average dose to the tumor cells by such a method could be improved by better methods of quantifying the in-vivo boron biodistribution. A better method of determining the in-vivo IOB …

    utk-theses Repository record for Use of ¹⁸F-BPA PET images and image registration to enhance radiation treatment planning for boron neutron capture therapy (opens in a new tab)

  19. Adaptive proton radiation therapy via fast Monte Carlo dose calculation to correct for inter- and intra-fraction motion and geometry changes

    … patient respiratory motion by defining planning target volumes based on a 4DCT of the patient. Density overwrites considering water-equivalent-path-length to voxels across the 4DCT targets works best. Project 4 demonstrates an online algorithm that maintains IMPT plan quality through treatment, …

    heid-diss Repository record for Adaptive proton radiation therapy via fast Monte Carlo dose calculation to correct for inter- and intra-fraction motion and geometry changes (opens in a new tab)

  20. Real-time tumor localization with electromagnetic transponders for image-guided radiotherapy applications

    … (non-ionizating radiation, three-dimensional target localization) and those of x-ray imaging (volumetric information about organ deformation and rotation, localization of organs at risk). The technique has been applied successfully to the elimination of motion artifacts in cone-beam computed …

    heid-diss Repository record for Real-time tumor localization with electromagnetic transponders for image-guided radiotherapy applications (opens in a new tab)

Page 1 of 5