Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 414 for “"Tdr"”

  1. Monitoring Slope Stability Problems Utilizing Electrical and Optical TDR

    <p>Electrical Time Domain Reflectometry (TDR) and Optical Time Domain Reflectometry (OTDR) were utilized to monitor a zone suspected to have a slope stability problem on SR 690, 7.8 miles east of the city of Athens, in southeast Ohio. Two pairs of cables – one coaxial (electrical TDR) and one fiber …

    ohiolink Repository record for Monitoring Slope Stability Problems Utilizing Electrical and Optical TDR (opens in a new tab)

  2. Impulse TDR and its Application to Characterisation of Antennas

    … using a step-function time domain reflectometer (TDR) along with frequency-domain processing techniques. Localisation of the measurement in time prior to transformation allows for the dismissal of unwanted spurious reflections, eliminating the need for an anechoic chamber. An alternative technique …

    waikato-masters Repository record for Impulse TDR and its Application to Characterisation of Antennas (opens in a new tab)

  3. Accuracy and Bias of TDR Measurements in Compacted Sands

    … parameters. Time domain reflectometry (TDR) is one such method. Relying on the propagation of an electromagnetic wave through the soil sample, TDR can be used to measure both in-situ moisture content as well as soil dry density. Although TDR is relatively new to the field of geotechnical …

    usf Repository record for Accuracy and Bias of TDR Measurements in Compacted Sands (opens in a new tab)

  4. PLC kullanılarak TDR ile tümleşik bir yüksek gerilim test cihazının tasarımı.

    … (Programlanabilir Mantıksal Denetleyici) tabanlı TDR (Zaman Alanı Reflektometresi) yöntemiyle çalışan bir taşınabilir yüksek gerilim kablo test ekipmanı tasarımı yapılmıştır. Tasarlanan ekipman, özellikle yeraltı enerji kablolarında TDR yönteminden faydalanılarak arıza ve arıza yeri tespiti …

    ogu-tr Repository record for PLC kullanılarak TDR ile tümleşik bir yüksek gerilim test cihazının tasarımı. (opens in a new tab)

  5. Design of a Multilevel - TDR Probe for Measuring Soil Water Content

    ABSTRACT The TDR measures soil water content by measuring the travel time of an electromagnetic step pulse through a wave guide embedded in the soil. Damage during insertion and retrieval of the probe makes it unsuitable for repeated use. A multilevel-TDR probe with adequate protection for cable …

    manitoba Repository record for Design of a Multilevel - TDR Probe for Measuring Soil Water Content (opens in a new tab)

  6. Time domain reflectometry (TDR) techniques for the design of distributed sensors

    … system consists of time domain reflectometry (TDR) signal processing equipment and specially designed sensing cables. The TDR equipment sends a high-frequency electric pulse (in the gigahertz range) along the sensing cable. Any change in electric impedance along the cable reflects some portion …

    vt Repository record for Time domain reflectometry (TDR) techniques for the design of distributed sensors (opens in a new tab)

  7. TDR Sensor for Chemical Analysis to Avoid Groundwater Contamination at CopperMining Facility

    … project the use of Time Domain Reflectometery (TDR) was assessed to analyze the impact of acids on subsurface soil at a copper mining facility. The basic method is the electrical conductivity of soil and its relation with the electrical potential along with dielectric constant. Since each …

    ohiolink Repository record for TDR Sensor for Chemical Analysis to Avoid Groundwater Contamination at CopperMining Facility (opens in a new tab)

  8. A Study on the Calibration and Accuracy of the One-Step TDR Method

    … parameters. Time domain reflectometry (TDR) is one such method. Several advances have been made over the past few years to further the use of TDR technology in water content and density measurement of compacted fill. The one-step method relies on the measurement of the apparent …

    usf Repository record for A Study on the Calibration and Accuracy of the One-Step TDR Method (opens in a new tab)

  9. Numerical methods in soil hydrology: TDR waveform analysis and water vapor diode simulation

    … water content from time domain reflectometry (TDR) measurements and simulate soil water accumulation in selected soil layers. TDR enables nondestructive and continuous soil water content measurements. Traditional TDR waveguides have relatively long probes (>150 mm), but new TDR waveguides tend …

    iastate Repository record for Numerical methods in soil hydrology: TDR waveform analysis and water vapor diode simulation (opens in a new tab)

  10. Application of e-TDR to achieve precise time synchronization and controlled asynchronization of remotely located signals

    Time Domain Reflectometer (TDR) measures the electrical length of a cable from the applied end to the location of an impedance change. An impedance change causes a portion of the applied signal to reflect back based on the value of its reflection coefficient. The time of flight (TOF) between the …

    texas Repository record for Application of e-TDR to achieve precise time synchronization and controlled asynchronization of remotely located signals (opens in a new tab)

  11. Time Domain Reflectometry Measurement of Water Content and Electrical Conductivity Using a Polyolefin Coated TDR Probe

    The use of time domain reflectometry (TDR) to determine water content (θv) from the measurement of the apparent dielectric constant (Ka) or the square root of the apparent dielectric constant (Ka 0.5) in highly saline environments has been limited due to the dampening effect that electrical …

    waterloo Repository record for Time Domain Reflectometry Measurement of Water Content and Electrical Conductivity Using a Polyolefin Coated TDR Probe (opens in a new tab)

  12. Thermo-TDR measurements of thermal properties and volume fractions of water, solids, and air in soil

    A thermo-TDR probe is a new device that allows rapid and accurate determination of soil thermal and electrical properties. The thermo-TDR was used to examine the relationships between thermal properties and the volume fractions of soil water ([Theta]), solids (v[Subfield s]), and air (n[Subfield …

    iastate Repository record for Thermo-TDR measurements of thermal properties and volume fractions of water, solids, and air in soil (opens in a new tab)

  13. Using rainfall simulation, TDR, and tracer anions to determine effects of soil properties on nitrate leaching

    … of non-destructive time domain reflectometry (TDR) techniques. A laboratory experiment was conducted to study the effects of different soil bulk density (1.10, 1.33, 1.57, and 1.81 g/cm 3) in the zone of N application and antecedent soil moisture by mass (10 and 15%) on NO3-N leaching during …

    iastate Repository record for Using rainfall simulation, TDR, and tracer anions to determine effects of soil properties on nitrate leaching (opens in a new tab)

  14. Concordância entre procedimentos de triagem auditiva e o teste de dígitos no ruído (TDR) em estudantes

    Introduction: Identifying hearing loss in students is essential to ensure adequate educational and social development. Objective: To assess the agreement between auditory screening procedures and the Hearing-in-Noise Test (HINT) adapted as the Digits-in-Noise Test (DIN) in students. Method: This …

    brazil-ufrn Repository record for Concordância entre procedimentos de triagem auditiva e o teste de dígitos no ruído (TDR) em estudantes (opens in a new tab) Embargoed until 2028-02-02

  15. The use of time domain reflectometry (TDR) to determine and monitor non-aqueous phase liquids (NAPLS) in soils

    … potential use(s) of Time Domain Reflectometry (TDR) to determine and monitor Non-Aqueous Phase Liquids (NAPLs) in soils. TDR is an established method to determine water content and electrical conductivity of soils. Other applications include solute transport and NAPLs migration in subsurface. A …

    ohiolink Repository record for The use of time domain reflectometry (TDR) to determine and monitor non-aqueous phase liquids (NAPLS) in soils (opens in a new tab)

  16. Is TDR in Virginia DOA? A Study of the State of Transfer of Development Rights Programs in Virginia

    … regarding obstacles and limitations to TDR program development and implementation, from every locality in the Commonwealth authorized to employ this tool. Based on findings of pertinent TDR literature, this research outlines the environment in which policy in Virginia is being developed …

    vcu Repository record for Is TDR in Virginia DOA? A Study of the State of Transfer of Development Rights Programs in Virginia (opens in a new tab)

Page 1 of 21