Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"Temperature-mapping"”.
-
Autonomous Small Scale Data-logger for Temperature Mapping
… and validation of a low cost small scale temperature data-logger used as a monitoring system for automated applications. The proposed system is battery powered and packaged in a manner able to operate in temperatures up to 100oC, with exposure to chemicals such as Isopropyl Alcohol, …
-
Microscale air temperature mapping in greater Vancouver, British Columbia
Background: Mobile air temperature monitoring is a promising method to better understand temperature distributions at fine spatial resolutions across urban areas and to minimize extreme hot weather health impacts. The first study objective was to collect pedestrian microscale air temperature data …
-
Self-Diffusion and Temperature Mapping of Food Materials Using MRI
… chemical composition, internal structure, and temperature of foods. Studying self-diffusion noninvasively using magnetic resonance imaging (MRI) techniques is useful for understanding dynamic phenomena which occur during food processing. The overall objective of this study was to measure the …
-
Feedback Control of Phased Array Electromagnetic Hyperthermia Using MRI Temperature Mapping
… technique is presented that allows noninvasive mapping of the relative phase patterns of the microwave fields inside a phantom. (3) An MRI-based technique is presented for closed loop spatial steering of the hot spot in a phased array system. (4) Noninvasive techniques are demonstrated that …
-
Temperature mapping of particles during aseptic processing via magnetic resonance imaging
… Magnetic Resonance Imaging (MRI) techniques for temperature measurement of particles undergoing aseptic processing were studied. A variable flip angle gradient echo sequence was initially tested. With this sequence T1 maps were obtained from two images acquired in sequence with a total imaging …
-
Droplet size, concentration, and temperature mapping in sprays using SLIPI-based techniques
… droplet size, droplet concentration, and liquid temperature in atomizing sprays. Two types of spray systems are investigated here: 1) Steady hollow-cone water sprays using temporally averaged imaging. 2) Transient Direct-Injection spark ignition (DISI) biofuel sprays using instantaneous imaging. …
-
Weighting Landsat Digital Data According to Land Cover Emissivity for Surface Temperature Mapping
… accurate data concerning land use/land cover and temperature gradients for informed decision making. Remotely-sensed data provide a method for acquiring such information in a dependable and efficient manner. Regular data acquisition and a synoptic view make the Landsat Thematic Mapper (TM) an …
-
Analytical method for turbine blade temperature mapping to estimate a pyrometer input signal
… is to develop a method to estimate local blade temperatures in a gas turbine for comparison with the output signal of an experimental pyrometer. The goal of the method is to provide a temperature measurement benchmark based on a knowledge of blade geometry and engine operating conditions. A …
-
Temperature Mapping of an Acoustically Forced Laminar Diffusion Flame using Planar Laser Rayleigh Scattering
… laser Rayleigh scattering was used to generate temperature maps of an acoustically forced laminar jet. Small scale enhancement was found to increase with frequency, while large scale vortices had competing effects in the range of the preferred mode. While vortices compacted the flame, increased …
-
MRI temperature mapping and finite element modeling of heat transfer in carrot particulates undergoing thermal processing
… magnetic resonance imaging to measure the temperature inside foods during heating. First, a steady state temperature gradient was applied to a model food gel. The T$\sb1$ temperature dependence for the gel was determined. A two dimensional Fourier transform spin echo imaging sequence was …
-
Surface temperature mapping of the University of Northern Iowa campus using high resolution thermal infrared aerial imagery
… collected. A model for the pixel to radiance and temperature conversion was developed with its parameters estimated with an R2 of 0.78. Temperature imagery was shown to be consistent over the time of the survey and accurate to within 12°C. The temperature map then was used to assess the conditions …
-
Using electrical conductivity and temperature mapping to locate zones of groundwater discharge in the South Nation River, eastern Ontario
… seepage from electrical conductivity and temperature (EC& T) of water at the bottom of the river, based on the assumption that there is a contrast between the incoming groundwater and the river water (which is almost always the case). Zones of groundwater seepage were confirmed and …
-
Advancing the Maximum Accelerating Gradient of Niobium-3 Tin Superconducting Radiofrequency Accelerator Cavities: RF Measurements, Dynamic Temperature Mapping, and Material Growth
… increased quality factors, twice the operational temperature (4.2 K instead of 2 K}), and almost twice the theoretical accelerating gradient--96 MV/m in a TESLA elliptical style cavity. These advances can reduce the size and complexity of particle accelerators while simultaneously making them more …
-
Measurement of brain temperature using magnetic resonance spectroscopic imaging
The study of brain temperature is important for a number of clinical conditions such as stroke, traumatic brain injury, schizophrenia and birth asphyxia (for neonates). A direct method to estimate brain temperature non-invasively will allow assessment of brain thermoregulation and its variation in …
-
Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping
… SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity …
-
Advanced Techniques in Magnetic Resonance-Guided High-Intensity Focused Ultrasound
… through skin. Heating the tissue to a temperature high enough, e.g., to 57°C, induces instantaneous cell death through thermal coagulative necrosis. Alternatively, HIFU can be used for hyperthermia, in which tissue temperature is maintained within a range of 40–45°C for a longer period …
-
Low-Cost Two-Color Pyrometry for Laser-Powder Bed Fusion
… a novel method for real-time, pixel-wise temperature measurement in L-PBF using a low-cost two-color pyrometry system built from synchronized Near-Infrared (NIR) cameras. The system uses two high-resolution USB 3.0 Basler acA5472 cameras—one monochrome and one color—outfitted with …
-
Gold nanoclusters and fluorescence-based sensing
… AuNCs@BSA was investigated and an aqueous-phase temperature sensor was achieved. In addition to AuNCs, we developed novel glutathione stabilized copper NCs with green-emission in assistance of ascorbic acid reduction, which showed great resistance to nitro compounds. Further, analytical …
-
Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy
Magnetic resonance temperature imaging (MRTI) is recognized as a noninvasive means to provide temperature imaging for guidance in thermal therapies. The most common method of estimating temperature changes in the body using MR is by measuring the water proton resonant frequency (PRF) shift. …
Page 1 of 3