Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 697 for “"Tendons"”.

  1. Prestressed BFRP tendons in concrete beams

    … structures are normally reinforced with steel tendons. In marine or chemical environment steel has its limitations. Replacing steel with FRP reinforcement has been practiced for many years but using basalt fiber reinforcement polymer tendons (BFRP) as a structural material is rather new. …

    reykjavik Repository record for Prestressed BFRP tendons in concrete beams (opens in a new tab)

  2. Viscoelastic Models for Ligaments and Tendons

    Collagenous tissues such as ligaments and tendons are viscoelastic materials. They exhibit a slow continuous increase in strain over time, or creep, when subjected to a constant stress and a slow continuous decrease in stress over time, or stress relaxation, when subjected to a constant strain. …

    vt Repository record for Viscoelastic Models for Ligaments and Tendons (opens in a new tab)

  3. Cathodic Protection of Corroded Pre-stressed Tendons

    … generation and subsequent embrittlement of the tendons. This research investigates the performance of pre-stressed steel tendon exposed to an impressed current cathodic protection (ICCP) at varying potentials on a long-term basis to establish its effect on strength and establish optimised …

    sheffield-hallam Repository record for Cathodic Protection of Corroded Pre-stressed Tendons (opens in a new tab) Download PDF for Cathodic Protection of Corroded Pre-stressed Tendons (opens in a new tab)

  4. Mechanical modelling and imaging of human tendons

    <p>Tendons are fibrous connective tissues which are saturated with fluid. Cells within the tendon control the production and organisation of tendon constituents in response to local mechanical signals. Tendinopathy is a painful condition characterised by collagen disruption, accumulation of …

    oxford Repository record for Mechanical modelling and imaging of human tendons (opens in a new tab)

  5. Optically Sensorized Tendons for Articulate Robotic Needles

    … routing. The performance of the sensorized tendons is explored in terms of strength (higher than 13N for the bare PM-FBG fiber tendon, up to 40N for the Kevlar-reinforced tendon under tensile loading), strain sensitivity (0.127 percent strain per newton for the bare PM-FBG fiber tendon, 0.04 …

    tamu Repository record for Optically Sensorized Tendons for Articulate Robotic Needles (opens in a new tab)

  6. Mechanobiological analyses of healing tendons using computational approaches

    <p>The healing process of ruptured tendons is problematic due to scar tissue formation and deteriorated material properties. In some cases, it may take nearly a year to complete. Mechanical loading has been shown to positively influence tendon healing; however, the mechanisms remain unclear. …

    oxford Repository record for Mechanobiological analyses of healing tendons using computational approaches (opens in a new tab)

  7. Mechanical and chemical properties of rotator cuff tendons

    … and biomechanical changes in torn rotator cuff tendons may help to reduce the high rerupture rates. This study aimed to characterise normal, and different sized rotator cuff tendon tears from small samples obtained intraoperatively to try to use tests that may potentially be clinically useful in …

    oxford Repository record for Mechanical and chemical properties of rotator cuff tendons (opens in a new tab)

  8. Tendons: structure, function and challenges to clinical treatment

    As dense connective tissues, tendons play a vital role in the transmission of contractile forces from muscle to bone. This link between muscles and bones provides the means in transferring tensile forces produced by muscles on to the connected bone. During movement, tendons slide over surrounding …

    bu Repository record for Tendons: structure, function and challenges to clinical treatment (opens in a new tab)

  9. Capacity of concrete beams prestressed with BFRP tendons

    Steinsteypt mannvirki eru yfirleitt járnbent vegna lágs togstyrks steypunnar. Járnbending hentar að mörgu leyti vel en hefur þann ókost að tærast sé hún ekki varin. Þetta á einkum við þar sem raki, selta eða önnur efnaáraun er mikil. Við slíkar aðstæður geta önnur efni verið heppilegri sem bending …

    reykjavik Repository record for Capacity of concrete beams prestressed with BFRP tendons (opens in a new tab)

  10. Evaluation of external post-tensioned tendons using vibration signatures

    … strands, cables specimens, and external tendons. A series of tension tests of individual strands were conducted to investigate changes in the uniaxial behavior after damage was induced. Simulated damage included uniform corrosion of the strand, mechanical wire cuts, and an initial defect …

    texas Repository record for Evaluation of external post-tensioned tendons using vibration signatures (opens in a new tab)

  11. Frequency response of damage [sic] external post-tensioned tendons

    Bridges with external post-tensioned tendons are considered to be more durable than bridges with internal tendons (tendons within the webs and flanges), because external tendons are easier to inspect. In addition, in the event that extensive corrosion damage is detected, it is possible to replace …

    texas Repository record for Frequency response of damage [sic] external post-tensioned tendons (opens in a new tab)

  12. Investigating mechanisms driving fibrosis in pathological rotator cuff tendons

    … the TGFβ axis in healthy and pathological tendons, and to study changes related to the epithelial to mesenchymal transition. We hypothesised that TGFβ family mediators would be dysregulated in pathological compared to healthy tendons. We also hypothesised that there would be evidence of …

    oxford Repository record for Investigating mechanisms driving fibrosis in pathological rotator cuff tendons (opens in a new tab)

  13. Impedance Analysis of Anodized Aluminum and Structural Bridge Tendons

    … detecting corrosion of steel in post-tensioned tendons which are used as reinforcing structural elements in segmental bridge construction. The tendons are composed of high-density polyethylene ducts that contain high-strength steel strands surrounded by cementicious grout. A proof of concept was …

    usf Repository record for Impedance Analysis of Anodized Aluminum and Structural Bridge Tendons (opens in a new tab)

  14. Inspection of Internal Post-Tensioned Tendons Using Nondestructive Testing

    … systems, the structural integrity of the PT tendons is critical. To protect the steel strands, a cementous grout material is injected into the ducts. However, the presence of grout voids in the tendons combined with the ingress of chlorides allows for corrosion of the steel strands. …

    tamu Repository record for Inspection of Internal Post-Tensioned Tendons Using Nondestructive Testing (opens in a new tab)

  15. Durability of non-metallic reinforcing bars and prestressing tendons

    … different commercially available FRP rebars and tendons. In addition, long-term relaxation losses and fatigue characteristics of two carbon and one aramid FRP tendons were also examined. Test results showed durability problems associated with E-glass and AR-glass FRP rebars, and excellent …

    arizona-thes Repository record for Durability of non-metallic reinforcing bars and prestressing tendons (opens in a new tab)

  16. Strengthening prestressed beams using parafil ropes as external tendons

    … Plastics (FRP) can be used instead of steel tendons. Within the different types of FRP, Parafil rope was established to be well suited for prestressing system, combining the benefits of light-weight, high strength, easy handling and efficient anchorage system. Thirteen prestressed beams,one …

    whiterose Download PDF for Strengthening prestressed beams using parafil ropes as external tendons (opens in a new tab)

  17. Corrosion of Post-Tensioned Tendons Repaired with Dissimilar Grout

    … in repaired systems in which the affected tendons have been re-grouted with dissimilar grouts. The presence of two distinct grouting materials, manifested by the existing/simulated base grout and a newly introduced repair grout, provided the dissimilar grout condition studied. Corrosion …

    unf Repository record for Corrosion of Post-Tensioned Tendons Repaired with Dissimilar Grout (opens in a new tab) Download PDF for Corrosion of Post-Tensioned Tendons Repaired with Dissimilar Grout (opens in a new tab)

Page 1 of 35