Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"Tension band"”

  1. Mechanical Evaluation of Pin and Tension-Band Factors in a Delrin Olecranon Osteotomy Model

    Pin and tension-band wire (PTBW) fixation is the most common method of repair for simple olecranon fractures and osteotomies despite relatively high rates of complications reported with this technique. A two-phase mechanical study was undertaken to evaluate the effect of altering PTBW fixation …

    ohiolink Repository record for Mechanical Evaluation of Pin and Tension-Band Factors in a Delrin Olecranon Osteotomy Model (opens in a new tab)

  2. TENSION BAND HERNIORRHAPHY IN CANINE PERINEAL HERNIA: EVALUATION OF THE ROLE OF COLOPEXY ON SURGICAL AND CLINICAL OUTCOME

    The objective of our study is to evaluate the influence of colopexy on both clinical and surgical outcome of dogs treated with perineal herniorrhapy and, if possible, to establish its impact on rectal dilatation. Moreover our second aim is to compare the results of our surgical approach to those …

    milano Repository record for TENSION BAND HERNIORRHAPHY IN CANINE PERINEAL HERNIA: EVALUATION OF THE ROLE OF COLOPEXY ON SURGICAL AND CLINICAL OUTCOME (opens in a new tab)

  3. A Biomechanical Comparison of a Low-Profile Mesh Plate Contrasted with Tension Band Wiring Treatment of Olecranon Fractures and Osteotomies

    … that exceed a 2 mm fragment displacement. The tension band wire (TBW) technique is the current standard of care for treating olecranon fractures due to its positive clinical results. However, the complication rate due to prominent hardware is reported to be upwards of 50\%. This research aims …

    unm Repository record for A Biomechanical Comparison of a Low-Profile Mesh Plate Contrasted with Tension Band Wiring Treatment of Olecranon Fractures and Osteotomies (opens in a new tab)

  4. Early range of motion exercise in pediatric patients with olecranon fractures treated with tension band suture with double loops and double knots

    … with olecranon fractures are uncommon. The tension band suture technique was introduced to reduce the burden of implant removal and other complications. However, to our knowledge, early range-of-motion exercise has not been introduced in this patient population. Double vicryl loops and knots …

    ajou Repository record for Early range of motion exercise in pediatric patients with olecranon fractures treated with tension band suture with double loops and double knots (opens in a new tab) Embargoed until 9999-12-31

  5. Biomechanical evaluation of two methods of surgical stabilization of the atlantoaxial joint

    … used in clinical cases. However, Kishigami tension bands are a less technically demanding procedure with potentially fewer complications. The purpose of this study was to biomechanically compare these two techniques in ventral-to-dorsal bending in both mature and immature dogs. Seventeen …

    vt Repository record for Biomechanical evaluation of two methods of surgical stabilization of the atlantoaxial joint (opens in a new tab)

  6. The effectiveness of anular repair as illustrated in an in vitro laboratory simulation

    … circular or slit defect (control); 2) a single tension band; 3) two tension bands in a cruciate pattern; and 4) two tension bands in a parallel configuration. Anular defects were repaired with the XcloseTM Tissue Repair System. Input pressure was increased until failure (i.e. extrusion of the …

    umn Repository record for The effectiveness of anular repair as illustrated in an in vitro laboratory simulation (opens in a new tab)

  7. Effect of a hip exotendon system on lower body muscle activity during forward skating accelerations

    … novel exotendon system designed to assist hip extension. Three levels of tension band stiffnesses were assessed (soft, medium, stiff) along with a control condition. Measures of root mean square (RMS) electromyographic (EMG) muscle activity were analyzed from five elite male ice hockey players …

    mcgill Repository record for Effect of a hip exotendon system on lower body muscle activity during forward skating accelerations (opens in a new tab)

  8. Ergebnisse einer retrospektiven Nachkontrolle operativ versorgter Olekranonfrakturen mit Beurteilung der Wertigkeit und Vergleichbarkeit von verschiedenen Scores

    Ziel: Ziel der Studie war es das Outcome der osteosynthetisch versorgten Olekranonfrakturen anhand 4 verschiedener Scores zu erfassen. Die Scores wurden auf ihre Vergleichbarkeit und Aussagekraft miteinander Verglichen. Methode: In einem Zeitraum von 9 Jahren kontrollierten wir die bei uns in der …

    fu-berlin Repository record for Ergebnisse einer retrospektiven Nachkontrolle operativ versorgter Olekranonfrakturen mit Beurteilung der Wertigkeit und Vergleichbarkeit von verschiedenen Scores (opens in a new tab)

  9. Studies on rotator cuff repairs

    … subject who could generate more than 100N. The tension band repair construct had higher footprint contact pressure compared to single and double row repair. Contact pressure and pull out strength were further enhanced by using a wider tape instead of the #2; suture. Transtendon repair of partial …

    unsw Repository record for Studies on rotator cuff repairs (opens in a new tab)

  10. Investigation of exogenous growth factors; platelet derived growth factor, insulin-like growth factor binding protein and fibroblast growth factor, and their influence on in vivo bone repair.

    … intramedullary pin and figure-of-eight tension band suture, with a 3 week survival period. The GFs tested in this model were 3 concentrations of PDGF, a single dose of insulin-like growth factor binding protein (IGF-BP) and a combination of the two. Each osteotomy was injected with a …

    unsw Repository record for Investigation of exogenous growth factors; platelet derived growth factor, insulin-like growth factor binding protein and fibroblast growth factor, and their influence on in vivo bone repair. (opens in a new tab)

  11. Mechanical Assessment of Veterinary Orthopedic Implant Technologies: Comparative Studies of Canine Fracture Fixation and Equine Arthrodesis Devices and Techniques

    … a two “figure-eight” 1.25mm stainless steel wire tension band. Fatigue tests and to failure tests were conducted. There were no significant differences in stiffness between groups for fatigue tests. Stiffness increased after the first fatigue cycle for the LCP/wire (80.56+/-52.22%) and DCP/wire …

    tamu Repository record for Mechanical Assessment of Veterinary Orthopedic Implant Technologies: Comparative Studies of Canine Fracture Fixation and Equine Arthrodesis Devices and Techniques (opens in a new tab)

  12. Σύνθετα (2, 3 και 4 τμημάτων) κατάγματα άνω πέρατος βραχιονίου. Διάγνωση, χειρουργική αντιμετώπιση και λειτουργική αποκατάσταση

    … σε ένα ενιαίο τμήμα, δίκην ταινίας ελκυσμού (tension band effect), που επιτρέπει την σταθερή οστεοσύνθεση του κατάγματος και διευκολύνει την πρώιμη κινητοποίηση του ώμου. Υλικό-Μέθοδος: Την χρονική περίοδο 1991-2003 αντιμετωπίστηκαν χειρουργικά στην κλινική μας με τη μέθοδο της οστεοσυρραφής …

    patras-thes Repository record for Σύνθετα (2, 3 και 4 τμημάτων) κατάγματα άνω πέρατος βραχιονίου. Διάγνωση, χειρουργική αντιμετώπιση και λειτουργική αποκατάσταση (opens in a new tab)

  13. Proximal forearm fractures: epidemiology, functional results and predictors of outcome

    … of the olecranon were carried out to compare 1) tension band wire (TBW) versus plate fixation in younger patients (<75 years) and 2) operative versus non-operative management in elderly patients (≥75 years). The primary outcome measure for these studies was the upper limb specific patient …

    edinburgh Repository record for Proximal forearm fractures: epidemiology, functional results and predictors of outcome (opens in a new tab)