Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 106 for “"Test cells"”
-
Improvement of engine inlet pressure control in jet engine test cells
… engine inlet pressure control in jet engine testing. This report documents a study in which a statistical regression method, using system data acquired on-line, was employed to model the system dynamics involved. From this model and a known engine disturbance (fan speed) a control strategy …
-
Controls and Measurements of KU Engine Test Cells for Biodiesel, SynGas, and Assisted Biodiesel Combustion
… other; however, they all include the concept of testing renewable or future fuel sources. The projects were the following: University of Kansas's Feedstock-to-Tailpipe Initiative's Synthesis Gas Reforming rig, Feedstock-to-Tailpipe Initiative's Biodiesel Single Cylinder Test Stand, and a unique …
-
Development and Implementation of test cells to perform DC and LI breakdown testing of materials used in HVDC cable accessories
… thesis work is to develop,build up and verify a test circuit for measurements of DC breakdown strength and LI testing. The work contains both practical and theoretical elements, focusing on optimizing the design of electrodes as well as the size and shape of samples and to determine the Optimal …
-
Arsenic Remediation Using Constructed Treatment Wetlands
… study, small scale (0.57 m x 0.17 m x 0.17 m) test cells were constructed to assess the ability of wetlands to remediate arsenic contaminated water. We have proposed a conceptual model that envelops the potential remediation processes, including soil, plants and microorganisms, within a …
-
Design of an Experimental Facility for the Validation of Cooling Load Calculation Procedures
Two test cells were constructed to validate the ASHRAE cooling load calculation procedures developed under RP-875 and codified in the ASHRAE Loads Toolkit (RP987). The test cells were designed to test the cooling load procedures' ability to accurately predict cooling loads dominated by solar and …
-
A Study of the Relationship Between Soil and Quantitative Terrain Factors
… selected. A sufficient number of 0.5-mile square test cells was established at random in each of the soil areas. Ten terrain factors were quantified in each of the test cells from data measured on either the topographic maps or the aerial photographs or both. The results showed that certain great …
-
Viability, Functionality, and Genetic Assessment of Cells After Laser Guidance
… and exposure time of the laser on single cells to clearly establish laser parameters that allow negligible cell damage with significant cellular position control. To accomplish this goal, embryonic day 7 (E7) chick forebrains neurons were cultured with control and test cells selected one …
-
Pulsed electric field treatment of Arthrospira platensis and Saccharomyces cerevisiae
… bio-membrane and cause the death of microbial cells without significant thermal effect, which can be used for inactivation of microorganisms and facilitation lysis of microbial cells for lipid extraction. The present study aimed to investigate the efficiency of PEF treatment of Arthrospira …
-
Towards Nearly Zero Energy Buildings in Lebanon: Bioclimatic Design and Experimental Strategies
… found while monitoring the apartments, three test cells with different double masonry walls and insulation configurations are built and their internal temperatures are monitored for a full summer season. They are maintained under a strictly-controlled environment. Later, these test cells are …
-
Defect spectroscopy on Cu(In,Ga)(S,Se) 2 -based heterojunction solar cells: role of the damp-heat treatment
… characteristics induced by accelerated lifetime tests on solar cells of the heterostructure ZnO/CdS/Cu(In,Ga)(S,Se)2/Mo are investigated. The fill factor and open-circuit voltage of non-encapsulated test cells are reduced after prolonged damp-heat treatment in the laboratory, leading to a reduced …
-
An experimental investigation of the near-field liquid patternation produced by two air-blast atomizers
… clouds in altitude simulation and icing research test cells, to simulate adverse weather flow conditions. Simulation of adverse weather in the engine test cells and wind tunnels is of great importance to the aerospace industry, since flight in adverse weather represents both safety and performance …
-
Determination of the Leak Size Critical to Package Sterility Maintenance
… 2, 5, 7, 10, 20 or 50 m, were measured using 63 test cells filled with safranin red dye, tryptic soy broth, and distilled water with surface tensions of 18.69 mN/m, 44.09 mN/m, and 64.67 mN/m, respectively. Significant differences were found between observed threshold pressures for safranin red …
-
FPGA Logic Design for Analog-to-Digital-Converter Hardware Utilizing High Speed Serial Data Links
… System (CADDMAS) used by the aeropropulsion test cells at Arnold Engineering Development Center (AEDC) processes a large amount of high bandwidth accelerometer and strain gage data. Data from each sensor must be digitized before being processed by software running on networked computers. This …
-
Electrochemical studies of microbiologically influenced corrosion in austenitic stainless steel weldments in the Tennessee River, Knoxville, Tennessee, and the Guadalupe River, Victoria, Texas
… MIC. In order to study these effects, two field test sites were chosen; (1) the Tennessee River in Knoxville, Tennessee, where MIC has been shown to be a problem for the Tennessee Valley Authority (TVA) fossil and nuclear plants; and (2) the Guadalupe River in Victoria, Texas, where MIC of …
-
Biofouling of membrane systems: characterization and impact of pre-treatment
… Thus, in the present thesis a membrane test cell was developed which enables the investigation of biofouling under validated, representative conditions of full-scale modules. Biofouling was studied in order to determine its impact on membrane performance. Also, appropriate, …
-
A Comparison of Frictional Forces During Simulated Cuspid Retraction on a Continuous Edgewise Archwire
… observed with the .016"x.022" stainless steel test cells. The largest frictional force was found in the .017”'x.025" Beta-Titanium retraction specimens. Nitinol revealed force data intermediate between stainless steel and Beta-Titanium. The maximum resistance assembly developed 2.3 times the …
Page 1 of 6