Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 187 for “"Test device"”.

  1. Development and design of a test device for cartilage wear studies

    … joints focused on friction behavior. Only a few tests dealing with cartilage wear were conducted. Most of the cartilage wear studies were carried out under exaggerated conditions which might change the wear mechanisms. Two studies were undertaken under conditions close to normal conditions …

    vt Repository record for Development and design of a test device for cartilage wear studies (opens in a new tab)

  2. Development of a Tow Capacity Test Device for Small Unmanned Vehicles

    … vehicles and payloads. To date, the unmanned test community has not standardized on an apparatus or test operating procedure (TOP) specifically for evaluating the towing capacity of small unmanned ground vehicles. Draw-bar testing has been adapted by several groups to quantify small unmanned …

    vt Repository record for Development of a Tow Capacity Test Device for Small Unmanned Vehicles (opens in a new tab)

  3. A rapid in situ test device to evaluate the compaction effort of aggregate piers

    <p>A current in situ test exists to evaluate a load-deformation relationship of aggregate piers. However, the test is lengthy, evaluates only non-production aggregate piers, and does not provide a record of compaction. It would be beneficial to evaluate production piers as they are installed. A new …

    iastate Repository record for A rapid in situ test device to evaluate the compaction effort of aggregate piers (opens in a new tab)

  4. A modified ring shear test device for determining the hydro-mechanical behaviour of unsaturated soils

    … automated modified ring shear apparatus for the testing of unsaturated soils using the axis translation technique. The system is fully automated and it can be used for conducting Constant Load and constant Suction (CLS) shear tests, Constant Volume and constant Suction (CVS) shear tests, Constant …

    ottawa-retro Repository record for A modified ring shear test device for determining the hydro-mechanical behaviour of unsaturated soils (opens in a new tab)

  5. Development of a Modified Anthropomorphic Test Device for the Quantification of Behind Shield Blunt Impacts

    … duration. This work modified an Anthropomorphic Test Device (ATD) to be used for the characterization of behind ballistic shield blunt impact loading profiles. The modified ATD was instrumented to measure impacts at the hand, wrist, forearm, and elbow to compare the force transfer at different …

    mcmaster Repository record for Development of a Modified Anthropomorphic Test Device for the Quantification of Behind Shield Blunt Impacts (opens in a new tab)

  6. DEVELOPMENT OF A TEST DEVICE TO MEASURE THE TRIBOLOGICAL BEHAVIOUR OF SHOE-SURFACE INTERACTIONS IN TENNIS

    … understanding and develop a robust, portable device to assess the friction characteristics of tennis surfaces that relate to playing performance and safety. To understand the tennis player’s response and adaptability to a tennis court surface, including friction in the shoe-surface interface, …

    whiterose Download PDF for DEVELOPMENT OF A TEST DEVICE TO MEASURE THE TRIBOLOGICAL BEHAVIOUR OF SHOE-SURFACE INTERACTIONS IN TENNIS (opens in a new tab)

  7. Comparing In Situ Submerged Jet Test Device and Laboratory Flume Methods to Estimate Erosional Properties of Cohesive Soils for Bank Stability Models

    … obtained using the in situ submerged jet test device (SJT) were measured against results from the closed-loop laboratory flume method for 12 cohesive bank sites. Additionally, SJT critical shear stress values were compared to values found via empirical relationships found in literature …

    ut-knoxville Repository record for Comparing In Situ Submerged Jet Test Device and Laboratory Flume Methods to Estimate Erosional Properties of Cohesive Soils for Bank Stability Models (opens in a new tab)

  8. Ion implanted GaAs Mesfet technology

    … and the Cr tends to diffuse during device processing. Undoped semi-insulating GaAs substrates can be grown by the Liquid Encapsulated Czochralski (LEC) technique and allow the possibility of forming active regions by the process of implanting dopants directly into the substrate. The …

    ubc Repository record for Ion implanted GaAs Mesfet technology (opens in a new tab) Download PDF for Ion implanted GaAs Mesfet technology (opens in a new tab)

  9. Characterization of elastic solids using finite element methods.

    … are calculated as numerical results. A possible test device for the experimental characterization of anisotropic solids is postulated, the precision of displacement measurements to be required for such a device being determined by random perturbation analysis. Numerical constants accurate to …

    nps Repository record for Characterization of elastic solids using finite element methods. (opens in a new tab)

  10. Disturbed state constitutive modeling and testing of solders in electronic packaging

    … a thermomechanical digital image correlation test device has been developed to investigate solder joint material behavior under thermal mechanical and cyclic loading. The test device is composed of two high precision actuators driven by two brushless servo-motors; a vacuum chamber used to …

    arizona-thes Repository record for Disturbed state constitutive modeling and testing of solders in electronic packaging (opens in a new tab)

  11. Testing and modeling of unsaturated interfaces.

    A conventional fully automated direct shear test device was modified to achieve the objectives of this study. The newly developed device, called the Unsaturated Interface Direct Shear Apparatus (UIDSA), was equipped for applying and maintaining suction as well as net normal stress. The UIDSA can be …

    oklahoma-thes Repository record for Testing and modeling of unsaturated interfaces. (opens in a new tab)

  12. The Effects of Distraction on the Simple Reaction Time of Normal and Retarded Students

    … high school students. Specifically, these tests were concerned with assessing the effect of various combinations of loud popular music and bright flashing lights upon an individual's ability to attend to a simple reaction test device.

    central-wash Repository record for The Effects of Distraction on the Simple Reaction Time of Normal and Retarded Students (opens in a new tab)

  13. Macro-scale direct shear device for studying the large displacement shear strength of soil-structure interfaces under very low effective normal stresses.

    This thesis describes a new macro-scale test device for assessing the large-displacement soil/solid interface shear strength at very low effective normal stresses (3 kPa to 6 kPa). The testing method arises from a need to obtain the interface friction between soils and epoxy-coated pipes under low …

    ubc Repository record for Macro-scale direct shear device for studying the large displacement shear strength of soil-structure interfaces under very low effective normal stresses. (opens in a new tab) Download PDF for Macro-scale direct shear device for studying the large displacement shear strength of soil-structure interfaces under very low effective normal stresses. (opens in a new tab)

  14. A COMPARATIVE STUDY OF MOS CAPACITORS FABRICATED ON SINGLE-CRYSTAL AND POLYCRYSTALLINE SILICON

    The properties of bulk and interface traps in device grade single-crystal silicon and solar cell grade polycrystalline silicon are studied and compared, using MOS capacitors with 1 mm diameter aluminium gates and approximately 1000 Å thick gate oxide as test device. The device capacitance and …

    nus Repository record for A COMPARATIVE STUDY OF MOS CAPACITORS FABRICATED ON SINGLE-CRYSTAL AND POLYCRYSTALLINE SILICON (opens in a new tab) Download file for A COMPARATIVE STUDY OF MOS CAPACITORS FABRICATED ON SINGLE-CRYSTAL AND POLYCRYSTALLINE SILICON (opens in a new tab)

  15. An experiment in the prediction of achievement in Senior Certificate higher grade mathematics

    … of the examination papers is discussed. A test device suitable for Standard Seven pupils is developed on the basis of the composition of the Higher Grade Matriculation examination papers analysed. The object of this test is to provide that early indication to pupils of their ability to cope …

    cape-town Repository record for An experiment in the prediction of achievement in Senior Certificate higher grade mathematics (opens in a new tab)

  16. Development of a portable rheometer for fresh portland cement concrete

    … this research was to identify an effective field test method for measuring the workability of concrete in general and of high-microfines concrete in particular. The workability of fresh concrete has traditionally been measured with the slump test, which provides an inadequate indication of …

    texas Repository record for Development of a portable rheometer for fresh portland cement concrete (opens in a new tab) Restricted access

  17. Friction, wear and lubrication of a poly(2-hydroxyethyl methacrylate) hydrogel

    … to evaluate friction and wear of polyHEMA. Tests were carried out using a friction and wear test device developed for biotribology research. The geometry consisted of a ball on flat; 6mm stainless steel ball and flat polyHEMA discs. Test factors were load, lubrication, hydration and material …

    vt Repository record for Friction, wear and lubrication of a poly(2-hydroxyethyl methacrylate) hydrogel (opens in a new tab)

Page 1 of 10