Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"Test gas"”.
-
Evaluation of Hydrogen as a Cryogenic Wind Tunnel Test Gas
… of hydrogen as a cryogenic wind tunnel test gas. By using Cryogenic hydrogen, instead of air or cryogenic nitrogen, as the wind tunnel test gas, a significant increase in the test Reynolds number may be achieved without increasing the aerodynamic loads. Under sonic conditions, for …
-
Mass spectrometry in shock tunnels
… and constructed to detect the onset of driver gas contamination in a free piston shock tunnel. A skimmer, which formed a molecular beam that was ionised and analysed by a quadrupole mass spectrometer, sampled the flow. The design and construction of the vacuum system, the ion source, and the …
-
A study of radiating argon flows at high opacities
… Experiments have been performed using argon as a test gas because the radiation loss with argon is quite considerable under the thermodynamic conditions experienced in this study. The nature of the experiments was mainly spectroscopic. This investigation has shown that?using a careful analysis^the …
-
Numerical simulation and modeling of shock tube experiments
… the formation of nonuniformities in shock tube test gases is investigated in the context of ideal gas simulations. Shock speed variations from -29% to +33% are found to influence temperatures in the test slug by as much as 55% in an Argon test gas with a tube-end 2100 m/s. These results give …
-
Removal of sulfur dioxide from an air stream by selected coal fly ashes in a bench-scale fixed-bed reactor
<p>In a series of exploratory tests the capacity for five United States coal fly ashes to absorb sulfur dioxide was measured under various temperature and moisture conditions. Tests were run at temperatures ranging from 75° F to 350° F. A simulated flue gas was passed through a fixed-bed of the …
-
Performance of an arc chamber
… studied with helium and hydrogen as the working gases. An optimum electrode gap and chamber diameter were determined for a stagnation pressure between 1 and 1.5 atmospheres by computing the efficiency of the unit for various values of these parameters. Two methods of increasing the specific …
-
Design of a submillimeter gas laser
A gas laser has been designed to 01lase over the entire far infra-red spectrum. This thesis discusses the theoretical and practical considerations that are involved in such a design. The three aspects of design that are discussed are the laser cavity, the excitation mechanism, and the detection …
-
Mass Spectrometric Studies of Oxygen Isotope Exchange Reactions with Oxide Surfaces
… of approximately 2%18o2 in neon was used as the test gas, and was passed over the surface of the oxides. Measurements were taken as a function of temperature and residence time, for kinetic studies. These studies clearly show a second order rate law for the surfaces examined. The rate constant on …
-
Modeling of non-equilibrium plasmas in an inductively coupled plasma facility
… results of the numerical simulation of ionized gas flows inside the torch of an inductively coupled plasma facility in the von Karman Institute for Fluid Dynamics. The main purpose of this work is the parametric investigation of thermo-chemical non-equilibrium effects on the plasma jet at different …
-
Experimental study of rare-gases excimer VUV system and H2 Lyman-bands calibration
An electron impact rare gas excimer vacuum ultra-violet experimental system is custom-designed and tested using an argon and H2 mixture. An electron flooding system, i.e. filament, is used as the hot electron source. A SiNx membrane is applied as the entrance foil separating the high vacuum chamber …
-
The production of hypersonic shock waves in an electrothermal diaphragm shock tube
… tube of 5 cm inside diameter in which the driver gas is heated by the discharge of electrical energy ( ~ 10³ joules) is analyzed in detail. A technique is described for the measurement of the heated driver gas pressure and empirical relations are obtained which enable the shock speed to be …
-
A high performance diaphragm shock tube with an imploding detonation driver.
… by the imploding front elevates the driver gas temperature and pressure above the usual Chapman-Jouguet values, thereby increasing the strength of the test shock. Theoretically, the relationship between test shock strength, filling pressure, and area reduction in a conical channel is …
-
The bacterial flora of raw bulk tank milk of fourteen farms in the Winnipeg area
… on the basis of the Gram stain, catalase test, coagulase test, gas production in lactose, and spore stain into eight categories. Of the 5550 pure cultures studied, 51.4% were micrococci, 20.0% Gram -ve rods, 19.2% streptococci, 2.7% asporogenous Gram +ve rods, 2.2% coliform organisms, 2.0% …
-
Analysis of a High-Temperature Spectroscopic Gas Cell Design
… experimental validation of parameters under test conditions. For this research, the design of a high-temperature, three-zone gas cell is proposed as a replacement for the current absorption cell system at The University of Tennessee Space Institute (UTSI). This new design, a prototype of …
-
Method to measure line shapes and relative transition probabilities
… state has been developed. Argon was used as a test gas to show that this method is more accurate than other current procedures. The experimental observations agree well with the theory developed in this thesis. It is shown that the ratio of the Lorentzian to Doppler half-widths of the line can …
-
Measurement of temperatures in unsteady gas flows
… measurement of the temperature of unsteady gas flows in a shock tube. The range of mach numbers for which the present system is designed is 1.1 to 1.4. This corresponds to a temperature directly behind the shock front in the range of about 318° K. to 373° K. The existing techniques of …
-
Post-Shock Relaxation of Air Species using Ab-Initio Data
… such quantities, particularly in cases where the test gas is not diluted with an inert species.
-
Shock wave and contact zone instabilities
… infinitely thin contact surface , separates the test sample from the driver gas, over a wide range of shock tube operating conditions. Severe distortions of the shock front are observed when this mixing zone is co incident with the shock wave. It is shown that these shock distortions can be …
-
Ionization of air produced by strong shocks
… modifications and deviations from the perfect gas theory for most simple mixtures of test gases is included. This program utilizes the latest available equilibrium constants for various gases. Also, this dissertation describes a technique which allows the electron concentration to be …
Page 1 of 3