Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 431 for “"Thd"”

  1. THD analyzátor

    Tato práce se zabývá návrhem THD analyzátoru pro audio kmitočty. Na úvod jsou popsány metody výpočtu THD a způsob realizace THD analyzátoru. Pro návrh THD analyzátoru je zvolena vhodná platforma schopná zpracovávat audio data. K ní je navržená rozšiřující deska, schopná snímání audio signálu. …

    brno-tech Repository record for THD analyzátor (opens in a new tab)

  2. Switching output stages for direct PCM-PWM amplification with enhanced PSRR and THD performance

    This thesis describes the process involved in designing the loop filter that is required when changing a class-D power output stage from a full-bridge configuration to a half-bridge. The loop filter designed is part of an error correction feedback network. This thesis covers the basic theoretical …

    ttu Repository record for Switching output stages for direct PCM-PWM amplification with enhanced PSRR and THD performance (opens in a new tab)

  3. Increasing the Dynamic Range of Audio THD Measurements Using a Novel Noise and Distortion Canceling Methodology

    … for measuring Total-Harmonic-Distortion (THD) of operational amplifiers functioned when compared with two standard methodologies, and whether the new methodology offers any improvement in noise floor and dynamic range along with distortion canceling of the sine-wave source used in the …

    unt Repository record for Increasing the Dynamic Range of Audio THD Measurements Using a Novel Noise and Distortion Canceling Methodology (opens in a new tab)

  4. Improving the Light Load Performance of Power Factor Correction Converters Using a Digital Controller

    … in terms of the total harmonic distortion (THD) of the converter, almost always is a trade-off for a reduction in overall converter efficiency. With increasing requirements for greater efficiency and lower THD, especially at output power loads much less than the rated output power of the …

    queens Repository record for Improving the Light Load Performance of Power Factor Correction Converters Using a Digital Controller (opens in a new tab)

  5. Harmonic distortion test development for class-D amplifier

    … The total harmonic distortion plus noise (THD+N) of an amplifier, along with its' efficiency, determines the quality of the amplifier. It has been determined that Class-D amplifiers are the most efficient of all the current Classes. The manufacturer's goal is to achieve the lowest possible …

    ttu Repository record for Harmonic distortion test development for class-D amplifier (opens in a new tab)

  6. Impact of charging of backup batteries by residential consumers on the low voltage distribution network.

    … supply voltage drop, total harmonic distortions (THD) and dc component produced at the point of common coupling by backup battery-charging using Simulink. Fourteen performance parameters which determined the quality of low voltage distribution network were reviewed. Eight of the performance …

    zambia Repository record for Impact of charging of backup batteries by residential consumers on the low voltage distribution network. (opens in a new tab)

  7. Synthesis and characterization of precursors for chemical vapor deposition of metal oxide thin films

    … CVD process. Lead bis-tetramethylheptadione [Pb(thd)₂], lead bis-heptafluorodimethyloctadione [Pb(fod)₂], and zirconium tetrakis-tetramethylheptadione [Zr(thd)₄], which are lead and zirconium precursors for CVD of Pb(Zr<sub>x</sub>Ti<sub>1-x</sub>)O₃ thin films, and T8- hydridospherosiloxane, …

    vt Repository record for Synthesis and characterization of precursors for chemical vapor deposition of metal oxide thin films (opens in a new tab)

  8. Mechanisms of Methanogenic Inhibition in Advanced Anaerobic Digestion

    … of thermally pretreated wastewater sludge (THD) were carried out. Enhanced digestion performance in terms of solids destruction and methane generation by THD relative to MAD was achieved, and was largely attributable to the solubilization and subsequent biodegradation of energy-rich …

    vt Repository record for Mechanisms of Methanogenic Inhibition in Advanced Anaerobic Digestion (opens in a new tab)

  9. Atomic layer deposition of lanthanide oxide thin films

    … processes for RE oxides are then reviewed. Ln(thd)3 and ozone were successfully utilized for deposition of most members of the Ln2O3 series. The deposited films were nearly stoichiometric Ln2O3 with only low concentrations of carbon, hydrogen, and fluorine impurities. Films were also uniform …

    aalto Repository record for Atomic layer deposition of lanthanide oxide thin films (opens in a new tab)

  10. Analysis of different topologies of multilevel inverters

    … with respect of power losses, cost, weight and THD. The switching pattern for inverters is explained as well. These inverters are connected to a 400V, 75kW asynchronous motor. For each inverter, IGBTs and MOSFETs are used as switching devices to make the comparisons more accurate. The switches …

    chalmers Repository record for Analysis of different topologies of multilevel inverters (opens in a new tab)

  11. Prevalença d'amiloïdosi de novo en receptors de fetges de donants amb polineuropatia amiloidòtica familiar

    … hepàtic (TH). El trasplantament hepàtic dòmino (THD) utilitzant fetges de donants amb polineuropatia amiloidótica familiar (PAF) és una font addicional d’òrgans amb resultats equiparables als dels donants cadàver. Els receptors tenen un risc potencial de desenvolupar amiloïdosi a llarg termini …

    barcelona Repository record for Prevalença d'amiloïdosi de novo en receptors de fetges de donants amb polineuropatia amiloidòtica familiar (opens in a new tab)

  12. Harmonic Mitigation in Dc-Ac Conversion by Utilizing Multi-Level Inverters and Its Application to Pv Systems for Grid Interconnection

    … filtering equipment.Total Harmonic Distortion (THD) for a square wave inverter is 48.34%; use of a multilevel inverter can significantly reduce this value. The first part of this thesis summarizes several harmonic minimization techniques for multilevel inverters. An equal angle approach can be …

    okstate Repository record for Harmonic Mitigation in Dc-Ac Conversion by Utilizing Multi-Level Inverters and Its Application to Pv Systems for Grid Interconnection (opens in a new tab)

  13. Designing and development of secure protection strategies for distribution network integrated with distributed energy resources

    … protection systems. Total Harmonic Distortion (THD) analysis has proven effective for fault detection in systems with complex harmonic profiles caused by DG integration. Faults induce increased harmonic distortion, making THD monitoring a valuable indicator. Despite its promise, protection …

    barcelona Repository record for Designing and development of secure protection strategies for distribution network integrated with distributed energy resources (opens in a new tab)

  14. Protection of distribution networks with distributed generation

    … microgrid protection. Total harmonic distortion (THD) based islanding detection schemes that measure the output current THD of the inverter interfaced DG (IIDG) are discussed and the role of various factors like uncertainties in filter parameters, variations in the utility THD and the utility …

    soton Repository record for Protection of distribution networks with distributed generation (opens in a new tab)

  15. Levantamento de harmônicas em redes de distribuição de uma concessionária de energia

    … the first step, measuring feeders, they had low THD's voltage and current within the limits of standard, single-family residence already had maximum voltage THD equal to 2.84 and a maximum THD current 28.7. There was predominance of 3rd and 5th harmonic voltage and the 3rd, 5th and 7th harmonic …

    brazil-ufpb Repository record for Levantamento de harmônicas em redes de distribuição de uma concessionária de energia (opens in a new tab)

  16. Tyrosine Hydroxylase Deficiency: Studies in patient samples and in a cellular model

    … Tyrosine Hydroxylase deficiency (THD), as a model of dopaminergic deficiency. Tyrosine hydroxylase (TH) enzyme catalyses the rate-limiting step in the biosynthesis of dopamine (DA). THD exhibits a wide spectrum of clinical manifestations that have been grouped according to the …

    barcelona Repository record for Tyrosine Hydroxylase Deficiency: Studies in patient samples and in a cellular model (opens in a new tab)

  17. LLC Resonant Converter Based Single-stage Inverter with Multi-resonant Branches

    … enlarges the gain range which improves output THD and reduces the switching frequency range. A 1.2 kW prototype is built to demonstrate the performance of the proposed inverter. Zero-voltage-switching (ZVS) and zero-current-switching (ZCS) are achieved on the primary side and secondary side, …

    vt Repository record for LLC Resonant Converter Based Single-stage Inverter with Multi-resonant Branches (opens in a new tab)

  18. Studium budičů anhydritových maltovin

    … věnována studiu dosavadního výzkumu na ústavu THD. V experimentální části je zpracován návrh potenciálních budičů hydratace na základě studia literatury a dle výsledků z dosavadního výzkumu na ústavu THD. Dále je navržena metodická koncepce práce. Následovalo zkoušení sledovaných …

    brno-tech Repository record for Studium budičů anhydritových maltovin (opens in a new tab)

Page 1 of 22