Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"Thermal conductivity detector"”.

  1. DEVELOPMENT OF PLATINUM BALANCED CANTILEVER-BASED THERMAL CONDUCTIVITY DETECTOR FOR GAS CHROMATOGRAPHY APPLICATION

    … focuses on developing a new generation of the thermal conductivity detectors. This research is aimed at enhancing the Limit of Detection (LOD), developing new measurement methods, developing new models to predict sensor behavior and bring TCD gas sensor technology together with gas …

    gatech Repository record for DEVELOPMENT OF PLATINUM BALANCED CANTILEVER-BASED THERMAL CONDUCTIVITY DETECTOR FOR GAS CHROMATOGRAPHY APPLICATION (opens in a new tab)

  2. MicroGC: Of Detectors and their Integration

    … This research focuses on the development of gas detectors and their integration, in different styles, primarily for gas chromatography. Utilizing fabrication techniques used in semiconductor industry and exploiting scaling laws we investigate the ability to improve on conventional gas separation …

    vt Repository record for MicroGC: Of Detectors and their Integration (opens in a new tab)

  3. The determination of the helium discharge detector response to fixed gases

    The Beckman Helium Discharge Detector has been found to be sensitive to the fixed gases oxygen, nitrogen, and hydrogen at detection levels 10-100 times more sensitive than possible with a Bow-Mac Thermal Conductivity Detector. Detection levels o~ approximately 1.9 E-4 ~ v/v oxygen, 3.1 E-4 ~ v/v …

    brock Repository record for The determination of the helium discharge detector response to fixed gases (opens in a new tab)

  4. Zebra GC: A Fully Integrated Micro Gas Chromatography System

    … (microPC), a MEMS separation column with on-chip thermal conductivity detector (microSC-TCD), the flow controller unit, and all the necessary flow and thermal management as well as user interface circuitry are integrated to realize the fully functional microGC system. The work reports extensive …

    vt Repository record for Zebra GC: A Fully Integrated Micro Gas Chromatography System (opens in a new tab)

  5. Síntese e caracterização de catalisadores a base de nióbio dopados com carbono por fotocatálise

    … bagasse, sodium alginate and sucrose. Hydrothermal and mechanical incorporation with subsequent heat treatment methods were used to prepare the photocatalysts. The catalysts were characterized by several techniques such as ultraviolet-visible spectroscopy (UV-vis), X-ray diffraction (XRD), …

    brazil-uerj Repository record for Síntese e caracterização de catalisadores a base de nióbio dopados com carbono por fotocatálise (opens in a new tab)

  6. Integration of a micro-gas chromatography system for detection of volatile organic compounds

    … and on its integration with an ultra-low power Thermal Conductivity Detector (TCD) for fast separation and detection of Volatile Organic Compounds (VOC). The major limitations of the current MEMS-GC column are: direct bonding of silicon to silicon, and peak band broadening due to slow …

    gatech Repository record for Integration of a micro-gas chromatography system for detection of volatile organic compounds (opens in a new tab)

  7. Computational and experimental development of ultra-low power and sensitive micro-electro-thermal gas sensor

    In this research a state-of-the-art micro-thermal conductivity detector is developed based on MEMS technology. Its efficient design include a miniaturized 100×2 µm bridge from doped polysilicon, suspended 10 µm away from the single crystalline silicon substrate through a thermally grown silicon …

    gatech Repository record for Computational and experimental development of ultra-low power and sensitive micro-electro-thermal gas sensor (opens in a new tab)

  8. Síntese e caracterização de catalisadores de LaNiO3 não suportados e suportados em Al2O3 e ZrO2 para a reforma a vapor do metano

    … the method of the polymeric precursors. The thermal treatment of the materials took place at 300 ºC for 2h. The material supported in alumina and/or zirconia was calcined at 800 ºC temperature for 4h. The samples had been characterized by the following techniques: thermogravimetry; infrared …

    brazil-ufrn Repository record for Síntese e caracterização de catalisadores de LaNiO3 não suportados e suportados em Al2O3 e ZrO2 para a reforma a vapor do metano (opens in a new tab)

  9. Catalytic control of nitric oxide with gaseous or solid reducing materials

    … Diesel powered vehicles, because of their higher thermal efficiency, tend to emit less carbon monoxide and unburned hydrocarbons than gasoline vehicles, but emit significant quantities of NO_x. Therefore, it is essential to develop improved emission control equipment in diesel engines. A fixed bed …

    njit Repository record for Catalytic control of nitric oxide with gaseous or solid reducing materials (opens in a new tab)

  10. Preparation and characterization of novel carbon material derived from resorcinol-formaldehyde xerogels for CO2 capture

    … a differential pressure transducer (DPT) and a thermal conductivity detector (TCD) respectively. The study demonstrates the potential of the surface chemistry of surface modified RF-carbon xerogels for the generation of efficient CO2 adsorbents, if their beneficial surface chemistry could be …

    strathclyde Repository record for Preparation and characterization of novel carbon material derived from resorcinol-formaldehyde xerogels for CO2 capture (opens in a new tab)

  11. Φωτοκαταλυτική αναγωγή του νερού με χρήση διθειολενικών συμπλόκων

    … the detection ofH2 a gas chromatographer with a thermal conductivity detector (TCD) was used.

    greece Repository record for Φωτοκαταλυτική αναγωγή του νερού με χρήση διθειολενικών συμπλόκων (opens in a new tab)

  12. Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.

    The Pulsed Discharge Helium Ionization Detector (PDHID) was compared to the Flame Ionization Detector (FID) and the Thermal Conductivity Detector (TCD) for High Speed Gas Chromatography (HSGC). It was shown that the PDHID is as sensitive as the FID but can be less reproducible. Moreover, the PDHID …

    nodak Repository record for Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples. (opens in a new tab)

  13. Measuring effective diffusivities in porous pellets: experimental procedures and FFT calculations

    … gas feed position, and flow rate through the thermal conductivity detector (TCD) on D[subscript] e, are shown. The height of the tracer dispersion cone above the top face of the pellet affected the value of D[subscript] e calculated. A model was proposed which separated the upper chamber …

    iastate Repository record for Measuring effective diffusivities in porous pellets: experimental procedures and FFT calculations (opens in a new tab)

  14. Design of a high pressure flow reactor for gas phase kinetics

    … feed to the Gas Chromatography Flame Ionization Detector (FID) and Thermal Conductivity Detector (TCD) were designed: a water-cooled sampling probe for faster residence times with greater control of experimental data, and a sampling syringe for ease of implementation for various testing setups. …

    colo-mines Repository record for Design of a high pressure flow reactor for gas phase kinetics (opens in a new tab)

  15. Selective no absorption from gas streams with tertiary organic hydroperoxide solutions

    … analyzed using a gas chromatograph (GC) with a thermal conductivity detector (TCD) or a chemiluminescent NO_x analyzer. A Fourier transform infrared spectrometer (FTIR) was used to determine organic product distribution and an ion chromatograph (IC) was used to measure inorganic products from …

    njit Repository record for Selective no absorption from gas streams with tertiary organic hydroperoxide solutions (opens in a new tab)

  16. Characterization of Pyrolysis Products from Fast Pyrolysis of Live and Dead Vegetation

    … and dead (biomass) plants undergo a two-step thermal degradation process (pyrolysis and combustion) when exposed to high temperatures. Pyrolysis is the thermal decomposition of organic material, which does not require the presence of oxygen. Pyrolysis products may later react with oxygen at …

    byu Repository record for Characterization of Pyrolysis Products from Fast Pyrolysis of Live and Dead Vegetation (opens in a new tab) Download PDF for Characterization of Pyrolysis Products from Fast Pyrolysis of Live and Dead Vegetation (opens in a new tab)

  17. Catalytically Enhanced Heterogeneous Combustion of methane

    … CCD camera, and a gas chromatograph with thermal conductivity detector which enable temperature measurements, acoustic spectroscopy, characterization of thermal radiative emissions, and composition analysis of exhaust gasses, respectively. Before evaluation of the various solid media in …

    ucf Repository record for Catalytically Enhanced Heterogeneous Combustion of methane (opens in a new tab)

  18. Catalysts for Hydrogen Production by the Auto-Thermal Reforming of Glycerol

    … study to develop an effective catalytic auto-thermal reforming process to convert glycerol into top value bio-based products. Glycerol can be converted to hydrogen-rich streams by steam reforming (SR), partial oxidation (POX), gasification, auto-thermal reforming (ATR), supercritical water …

    regina Repository record for Catalysts for Hydrogen Production by the Auto-Thermal Reforming of Glycerol (opens in a new tab) Download PDF for Catalysts for Hydrogen Production by the Auto-Thermal Reforming of Glycerol (opens in a new tab)

Page 1 of 2