Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 647 for “"Thermocouple"”.
-
Antenna-coupled thermocouple infrated detector
Master of Science (M.S.)
-
An Evaluation of Thermocouple Reconstruction Techniques
… and not able to see within the environment. Thermocouples are popular sensors because they are cheap and easy to implement across a wide range of applications and can measure temperature in areas where other methods cannot reach or see. However, while these sensors are very popular and …
-
Thermocouple Temperature Measurements for Twin Jet Thermal Mixing
<p>Thermocouples are commonly used devices for temperature measurement. This study concerns the implementation of thermocouples to collect thermal mixing data in an environment in which two parallel water jets are mixing. The measurements are taken with the purpose of modeling the jet mixing region …
-
Uncooled Infrared Detector Featuring Silicon based Nanoscale Thermocouple
… features a single standalone polysilicon-based thermocouple (without a supporting membrane) covered by an umbrellalike optical-cavity IR absorber. It is proved that the highest responsivity in the developed detectors can be achieved with only one thermocouple. Since the sub-micrometer …
-
Materials for High Temperature Thin Film Thermocouple Applications
The thermocouple systems used for the measurement of surface temperature in high temperature applications such as advanced aerospace propulsion systems and diesel engine systems are expected to perform in rapidly fluctuating and extremely high heat fluxes corresponding to high temperatures (in …
-
High Speed CO Thermometry in a Shock Tube with Thermocouple Insert
The Navy is interested in comparing multi-thermocouple probes, tested in the field, with scanned laser absorption thermometry. This comparison aims to understand the effects of excess Carbon Monoxide (CO) and carbon (soot) resulting from rich nitromethane (CH3NO2) combustion events interacting with …
-
Application of thermocouple psychrometers to field measurements of soil moisture potential.
The recent development of the peltier-type thermocouple psychrometer has made possible the measurement of soil moisture potentials to values as low as -80 bars. The applicability of this type of psychrometer to "in situ" measurements of moisture potential at a Sonoran desert field site is …
-
A dual-junction thermocouple probe for compensated temperature measurement in reacting flows
… The system under study uses the responses of two thermocouples of different sizes placed in close proximity in order to determine instantaneous temperatures. This is in contrast to previous work in which compensation is performed on a single thermocouple junction in order to correct for the error …
-
Experimental Study of the Nano-Fin Effect (NFE) During Thin Film Evaporation from Nanopores in Anodic Aluminum Oxide (AAO) Membrane Substrates Integrated with Nano-Thermocouple / Thin Film Thermocouple (TFT) Array
… used in this study include mounting a nano-thermocouple array (also termed as Thin Film Thermocouples or “TFT”) on a hot plate and observing the transient response recorded by the TFT array when a small liquid droplet (of fixed mass or volume) is dispensed on to an AAO membrane containing …
-
Experimental Study of the Nano-Fin Effect (NFE) During Thin Film Evaporation from Nanopores in Anodic Aluminum Oxide (AAO) Membrane Substrates Integrated with Nano-Thermocouple / Thin Film Thermocouple (TFT) Array
… used in this study include mounting a nano-thermocouple array (also termed as Thin Film Thermocouples or “TFT”) on a hot plate and observing the transient response recorded by the TFT array when a small liquid droplet (of fixed mass or volume) is dispensed on to an AAO membrane containing …
-
Development of a smart temperature measurement system based on a self-calibrating thermocouple
… of a commercially available self-calibrating thermocouple (a thermocouple with a high-purity, low-melting-point metal encapsulated near the thermojunction) connected to a data acquisition system with a specially designed algorithm capable of automatically detecting the calibration temperature …
-
Development of a wire identifier and its application to a thermocouple instrumentation system
… frequency range of 1 kHz to 1 MHz for a two foot thermocouple line connecting the interrogator to the specially equipped sensor. Varying the type and increasing the length of the connecting wire between the identifier and the interrogator may further limit this frequency range. The developed …
-
An Approach to Thermocouple Temperature Measurements that Reduces Uncertainties Associated with Radiative Corrections
… measurements in flame environments with thermocouples is extremely challenging due to the effects of radiative heat loss. These losses are difficult to quantify and often cannot be corrected for or minimized without sacrificing spatial resolution. In this work, a new experimental …
-
Metingen van de huiddoorbloeding: methodische en klinische ervaringen met het 'heated thermocouple' principe
Contains fulltext : mmubn000001_239068777.pdf (Publisher’s version ) (Open Access)
-
Development of a smart temperature measurement system based on the multi-lead thermocouple concept
… system (STMS) based on the concept of multi-lead thermocouples (MTC) was developed and tested. The system consists of a MTC, an interface, and a knowledge base. The MTC is comprised of five thermo-elements sharing a single measuring junction that provides up to ten estimates of the temperature. …
Page 1 of 33