Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"Thermocouple Probe"”.
-
A dual-junction thermocouple probe for compensated temperature measurement in reacting flows
… The system under study uses the responses of two thermocouples of different sizes placed in close proximity in order to determine instantaneous temperatures. This is in contrast to previous work in which compensation is performed on a single thermocouple junction in order to correct for the error …
-
Design and performance of a shieled high velocity thermocouple probe in a high-temperature, seeded-coal-combustion exhaust stream
… expended trying to improve the design of the probe-mounted High Velocity Thermocouple (HVT), which has been used as a temperature sensor. The main problems that appear to affect the recorded temperatures are particulate blockage of the probe and radiation & conduction heat losses from the …
-
Development of electric probes to detect phase change at a heated surface.
Two types of electric resistance probe have been developed to detect the rewetting of a heated surface, during quenching experiments. Measurements of electric resistance were made using two different methods: (i) Two-Electrode measurement, through a thermocouple probe; (ii) Probe-to Wall …
-
Numerical Simulation of Microwave Sintering of Zinc Oxide
… of zinc oxide, particularly dielectric loss. Two thermocouple probes were used to measure the temperature response in a small cylindrical sample of zinc oxide packed in powder insulation, and heated in a microwave oven. In order to determine if the unusual response is caused by the dielectric …
-
Development of a temperature probe radiation shield which is heated by the combustion of gases
… cooling causes significant heat losses in thermocouples at temperatures as low as 1200° Fahrenheit, which increases with increased temperature. Detailed analysis of error causing effects for thermal exchange is not possible since a detailed knowledge of the thermal environment must be …
-
Development of thermal hydraulic correlations for the University of Texas at Austin TRIGA reactor using computational fluid dynamics and in-core measurements
… dynamics code, FLUENT, along with real-time thermocouple probe measurements of the channel were used to solve both of these major issues. A high resolution model of four adjacent flow channels was created to provide a numerical experimental data set for enhancing the correlations used in the …
-
Natural convection liquid immersion cooling of high density columns of discrete heat sources in a vertical channel.
… were measured using a centrally located embedded thermocouple. Temperature measurement within the flow was conducted using a thermocouple probe. Flow visualization was conducted with the use of a laser generated plane of light. A visual temperature profile of the board was developed through the …
-
AN INVESTIGATION ON THERMAL CHARACTERISTICS OF PREMIXED COUNTERFLOW FLAMES USING MICRO-THERMOCOUPLES
… measurements were made utilizing a micro-thermocouple probe. To improve the measurements, the thermocouple support design was enhanced and corrections were made for measurement errors where appropriate. Trends observed in experimental and modeling temperature profiles with changes in fuel …
-
A preliminary attempt at sintering an ultrafine alumina powder using microwaves
… aid. The oven was modified by inserting a thermocouple probe through the bottom housing, and thoroughly insulating the interior with insulating material. The oven was placed in a glove box and filled with argon to prevent degradation of the thermocouple, and oxidation of the powdered …
-
Estimation of Surface Temperature and Heat Flux Using Embedded Thermocouples
… surface temperature and heat flux based on thermocouples embedded within the interior of a test article. The test apparatus was a Mach 2 axisymmetric rocket nozzle with probes embedded at depths of 1/8” and 1/4” from the inner surface of the nozzle at the throat and exit locations. Three …
-
Temperature elevations due to NIR exposure in the brain tissue
… measurements were made directly using a thermocouple probe inside the rat brain cortex within the sagittal plane. The spatial map indicates that N I R light penetrates more readily in the vertical directions than the spreading in the horizontal axis. The decrease in the vertical direction …
-
The controlled synthesis and characterisation of magnesium particles with nano-morphologies via physical vapor deposition for hydrogen storage
… A temperature gradient is studied by taking thermocouple-probe readings at measured positions from the furnace heater to the exit end of the tube for the range experimental parameters. Subsequent substrate placement at these positions is used as a means of natural T\(_d\) control, and an …
-
CAPITAL IN NEBRASKA AGRICULTURE: ITS FORMATION, DISTRIBUTION, AND FINANCING.
… flow rate by means of a modified high velocity thermocouple probe placed immediately above the packing. All nonisothermal runs were made with the tube wall temperature constant at 231°F.Radial mass transfer rates were expressed in terms of modified Peclet numbers (DpV/Eta). In the region of …
-
Analytical Corrections to a Numerical Procedure for Estimating Gas Stagnation Temperature fromThermocouple Measurements
… by a radiation – shielded, self – aspirated thermocouple (TC) probe. The numerical procedure breaks down the components of the thermocouple probe into individual but thermally interacting thermal bodies. The numerical procedure assumes that the measured TC tip temperature is a true value, and …
-
Ice-nucleating active bacteria: A novel approach to the management of the red imported fire ant
… At the end of each seven-day interval, a thermocouple probe was used to determine whole body supercooling points of randomly selected worker ants from each colony. In addition, head capsule widths and whole body weights were measured. Analysis of variance indicated a significant difference …
-
Effect of radio-frequency electromagnetic fields on nervous tissue
… brain tissue slice was not quantifiable by micro-thermocouple probe, due to perturbation of the E-field by the metal thermocouple. Non-perturbing temperature probe and thermal imaging camera measurements could not discern any measurable temperature rise during RF exposure due to inadequate …
-
Thermal convection at high Rayleigh numbers in compressed gases.
… measurements were taken using a 76μ m thermocouple probe. The temperature measurements are at significant variance from the expected temperature distribution in the thermal boundary layer. Conduction effects in the probe are shown to be significant. Temperature statistics measured with …
-
On natural convection in a large civil gas turbine
… of these flow fields. Furthermore, a robust thermocouple probe has been developed that allows for accurate measurements in a natural convective boundary layer, along with a novel method of determining heat flux fluctuations.</p> <p>An extensive experimental study has shown that the overall …
-
Experimental and Numerical Characterization of Turbulent Slot FIlm Cooling
… Particle Image Velocimetry (PIV) and a micro-thermocouple probe, respectively. These comprehensive measurements provide a unique data set for characterizing the momentum and thermal mixing of the turbulent flows, and for validating turbulence models in Reynolds averaged Navier-Stokes (RANS) …
-
Experimental verification of a heat/mass transfer analogy in two dimensional laminar and turbulent boundary layers.
… within 2%. The effect of conduction within the thermocouple wires is studied with a numerical model using fin analysis and a variable convective heat transfer load. The equilibrium thermocouple temperature is solved for various locations of the thermocouple probe within the boundary layer to …
Page 1 of 2