Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 684 for “"Thermocouples"”.

  1. Stability of Nuclear Thermocouples

    … IV reactor conditions is limited. Currently, thermocouples are the most commonly used temperature monitors within nuclear reactors. The primary motivation of this dissertation was to investigate the stability of High Temperature Irradiation Resistant thermocouples (HTIR-TCs) in addition to …

    boise Repository record for Stability of Nuclear Thermocouples (opens in a new tab)

  2. Ageing effects on iron-constantan thermocouples

    vt Repository record for Ageing effects on iron-constantan thermocouples (opens in a new tab)

  3. Determination of Thermal Properties Using Embedded Thermocouples

    <p>The Purpose of this thesis is to experimentally demonstrate an inversion analysis technique, developed by Dr. Jay Frankel (UTK), that utilizes transient temperature data from probes embedded at known locations in a material. This allows one to determine thermal properties (thermal diffusivity …

    ut-knoxville Repository record for Determination of Thermal Properties Using Embedded Thermocouples (opens in a new tab)

  4. Low Power Remote Sensing System for Ceramic Thermocouples

    … available which can be used to interface these thermocouples at low-cost and low power for accurate temperature measurement. An electronic system is needed to use these ceramic sensors which consumes less amount of power for an extensive period of time with remote monitoring option. This thesis …

    wvu Repository record for Low Power Remote Sensing System for Ceramic Thermocouples (opens in a new tab)

  5. A Data Acquisition System for 300 Quasi-grounded Thermocouples

    … project at South Dakota State University, 310 thermocouples were installed in and under a slab-on-grade concrete floor. During the installation two irregularities were introduced; the thermocouple junctions were constructed from extension grade thermocouple wire and the welded thermocouple …

    sdstate Repository record for A Data Acquisition System for 300 Quasi-grounded Thermocouples (opens in a new tab)

  6. Conduction Error in Thermocouples Embedded in Low Conductivity Material

    Thermocouples are generally used as devices to determine the internal temperature of any material. The purpose of the temperature measuring device is to measure the temperature which would exist at some known location if the device were not present. The thermocouples are embedded in the material in …

    byu Repository record for Conduction Error in Thermocouples Embedded in Low Conductivity Material (opens in a new tab) Download PDF for Conduction Error in Thermocouples Embedded in Low Conductivity Material (opens in a new tab)

  7. Estimation of Surface Temperature and Heat Flux Using Embedded Thermocouples

    … surface temperature and heat flux based on thermocouples embedded within the interior of a test article. The test apparatus was a Mach 2 axisymmetric rocket nozzle with probes embedded at depths of 1/8” and 1/4” from the inner surface of the nozzle at the throat and exit locations. Three …

    ut-knoxville Repository record for Estimation of Surface Temperature and Heat Flux Using Embedded Thermocouples (opens in a new tab)

  8. Heat Transfer In Intrinsic Thermocouples;Application To Transient Temperature Measurement Errors.

    The use of intrinsic thermocouples to measure rapid temperature variations of electrically conductive materials has become increasingly popular because of their unique characteristics: rapid response, versatility, reliability, relative simplicity and low cost. However, in some of the applications, …

    unm Repository record for Heat Transfer In Intrinsic Thermocouples;Application To Transient Temperature Measurement Errors. (opens in a new tab)

  9. AN INVESTIGATION ON THERMAL CHARACTERISTICS OF PREMIXED COUNTERFLOW FLAMES USING MICRO-THERMOCOUPLES

    Hydrogen addition is known to improve the stability of highly strained hydrocarbon premixed flames. Since the flame temperature is an important factor associated with extinction, it is of interest to study the thermal characteristics of the hydrogen-doped flames near extinction. Temperature …

    maryland Repository record for AN INVESTIGATION ON THERMAL CHARACTERISTICS OF PREMIXED COUNTERFLOW FLAMES USING MICRO-THERMOCOUPLES (opens in a new tab)

  10. Design, fabrication, packaging and testing of thin film thermocouples for boiling studies

    … during boiling. Microfabricated thin film thermocouples were used in this study. The main aim of this study was to develop a repeatable procedure for fabrication of thin film thermocouples and to test them by measuring surface temperatures during various boiling regimes. Since thin film …

    tamu Repository record for Design, fabrication, packaging and testing of thin film thermocouples for boiling studies (opens in a new tab)

  11. Analysis of Stresses in Metal Sheathed Thermocouples in High-Temperature, Hypersonic Flows

    … [6] and the new structural low-order model for thermocouples was developed. This code is capable of solving a highly generalized version of the 1-D pin fin equation, allowing for the solution of the temperature distribution in a sensor taking into account conduction, convection, and radiation …

    vt Repository record for Analysis of Stresses in Metal Sheathed Thermocouples in High-Temperature, Hypersonic Flows (opens in a new tab)

  12. Heat Transfer in Beaded Thermocouples Mounted on Solid Substrates-- Application to Transient Measurement Errors

    Beaded thermocouples mounted on the surface of a solid for the purpose of measuring surface temperature are liable to introduce measurement errors as a result of heat transfer between the surface and the bead, and also because of the thermal inertia of the bead. For the prediction or correction of …

    unm Repository record for Heat Transfer in Beaded Thermocouples Mounted on Solid Substrates-- Application to Transient Measurement Errors (opens in a new tab)

  13. Heat Flux Model Validation Utilizing Convolutional Neural Networks and Sub-surface Thermocouples for NSTX-U

    … for operation of NSTX-U. Sub-surface thermocouples will be utilized to demonstrate validation of the heat load model, using the castellated designs to quantify the shot-integrated energy deposited in the NSTX-U divertor. A Convolutional Neural Network (CNN) has been trained using ANSYS …

    ut-knoxville Repository record for Heat Flux Model Validation Utilizing Convolutional Neural Networks and Sub-surface Thermocouples for NSTX-U (opens in a new tab)

  14. Thermal Response Characterization and Low Fluid Velocity Measurements Using Specialized In-Situ Thermocouples Via The Loop Current Step Response Method

    … Thermal response characterization of installed thermocouples is essential in order to obtain accurate positional temperature data in rapid transient applications. An analytical model is presented that fully describes the thermocouple system based on a first-principles approach to the heat …

    ut-knoxville Repository record for Thermal Response Characterization and Low Fluid Velocity Measurements Using Specialized In-Situ Thermocouples Via The Loop Current Step Response Method (opens in a new tab)

  15. FIBRE OPTIC COUPLED, INFRARED THERMOMETERS FOR PROCESSES INCURRING HARSH CONDITIONS

    … thermometers (IRTs) that could substitute for thermocouples in harsh conditions that would affect contact temperature measurements deleteriously. The IRTs have been configured without photodiode cooling and signal chopping but achieved low minimum measurable temperatures, fast responses and …

    whiterose Download PDF for FIBRE OPTIC COUPLED, INFRARED THERMOMETERS FOR PROCESSES INCURRING HARSH CONDITIONS (opens in a new tab)

  16. Leveraging Machine Learning (ML) for Enhancing Sustainability, Reliability, Robustness and Resilience in Thermal Energy Storage (TES) Applications Using Phase Change Materials (PCM)

    … Temperature transients were recorded by three thermocouples immersed in the PCM (termed as “PCM thermocouples”). Three additional thermocouples were mounted on the outer surface of the cylinder (termed as “surface thermocouples”). Each set of transient temperature data (for a chosen constant …

    tamu Repository record for Leveraging Machine Learning (ML) for Enhancing Sustainability, Reliability, Robustness and Resilience in Thermal Energy Storage (TES) Applications Using Phase Change Materials (PCM) (opens in a new tab)

  17. A dual-junction thermocouple probe for compensated temperature measurement in reacting flows

    … The system under study uses the responses of two thermocouples of different sizes placed in close proximity in order to determine instantaneous temperatures. This is in contrast to previous work in which compensation is performed on a single thermocouple junction in order to correct for the error …

    vt Repository record for A dual-junction thermocouple probe for compensated temperature measurement in reacting flows (opens in a new tab)

Page 1 of 35