Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 24 for “"Thermosiphon"”.
-
Experimental study of thermosiphon performance
A model single phase loop thermosiphon was designed and built such that velocity profiles and heat transfer rates could be studied by obtaining temperature data, along with a detailed set of non-intrusive Laser Doppler Velocimetry measurements. The quantities measured were the instantaneous …
-
Modeling and optimization of a thermosiphon for passive thermal management systems
An optimally designed thermosiphon for power electronics cooling is developed. There exists a need for augmented grid assets to facilitate power routing and decrease line losses. Power converter augmented transformers (PCATs) are critically limited thermally. Conventional active cooling system …
-
Evaluation of Energy and Airflow Performance of Data Centers with Centralized Thermosiphon
… an indirect airside free cooling based on thermosiphon loop is proposed and investigated to reduce energy consumption and improve the IT equipment reliability in a novel vertical data center (VDC) which is designed by Vert.com Inc. An energy model was established to evaluate the energy …
-
SYSTEM PERFORMANCE ENHANCEMENT OF MOBILE COOLING SYSTEM WITH THERMAL BATTERY AND THERMOSIPHON RECHARGE
… by rejecting heat stored in the PCM with a thermosiphon recharge cycle. The PCM was enhanced with copper and graphite matrices. The system was tested with the goal of increasing the coefficient of performance (COP) of the VCC and decreasing the PCM recharge time. This study found that a …
-
CPU Cooling in Data Center Using a Thermosiphon Loop with Tapered Open Microchannel Manifold (OMM)
… cost to the system. The great potential of a thermosiphon system as a replacement of currently used cooling techniques is studied in the presented work. A thermosiphon loop using two-phase heat and mass transfer process uses latent heat of the working fluid. The latent heat is much more …
-
A Thermosiphon Loop for High Heat Flux Removal using Flow Boiling of Ethanol in Open Microchannel Manifold (OMM) with Taper
… in developing a low pressure drop system like a thermosiphon loop. To this end, a gravity-driven flow boiling system developed earlier was tested at low flow rates using ethanol. Based on the pressure drop and heat transfer data, a two-phase thermosiphon loop with a small ethanol head below 0.2 m …
-
High Heat Flux Dissipation Using Innovative Dual Tapered Manifold in Pool Boiling, and Thermosiphon Loop for CPU Cooling in Data Centers
… tapered microgap design is also implemented in a thermosiphon loop for CPU cooling where no pumping power is required for fluid circulation in a closed loop. The loop contains an evaporator with a dual tapered microgap and was able to dissipate heat from an actual CPU (i7-930 processor, TDP 130W) …
-
Soil Temperature and Moisture Control in Ground Source Heat Pump Systems
… were soil moisture control, presence of thermosiphon (TS), and effects of soil type. A single U-loop of a GSHP system was modeled in a soil domain using a finite element analysis (FEA) software Ansys Mechanical. The Backward Euler formulation and the Sparse Direct Solver were used to …
-
Experimental and Numerical Investigation of Solar Airflow Windows
<p>Solar thermosiphons integrated into the thermal envelop of buildings has been studied for their potential to take advantage of solar energy in heating buildings. The annual performance of solar thermosiphons cannot currently be predicted with the correlations from previous research. Also, no …
-
Design, Test, and Comparison of a Photovoltaic Thermal Hybrid Solar Collector Utilizing a Thermosiphon, and Theory and Analysis of Related Predictive Computer Model
… density changes from solar radiation, creates a thermosiphon, moving water without the use of a pump and ultimately drawing heat away from the solar panel. This is done to create a more efficient solar panel as well as decreasing potential damage due to high temperatures. Evaluation of electrical …
-
Passive thermal management of distribution grid assets
… on the thermal transport of single-phase closed thermosiphon systems incorporating a secondary parallel flow path for cooling an additional, typically smaller, thermal load associated with the power electronics converters. Dual-loop thermosiphon passive thermal management systems were …
-
BATTERY POWERED PORTABLE VAPOR COMPRESSION CYCLE SYSTEM WITH PCM CONDENSER
… by using the vapor compression cycle as a thermosiphon loop. The main focus of the current research was on the development of the cooling system. The cooling capacity of the vapor compression cycle measured was 165.6 W with system COP at 2.85. It was able to provide 2 hours cooling without …
-
Mathematical Modeling Of Transport And Corrosion Phenomenon Inside High Temperature Molten Salt Systems
… model was designed and benchmarked against a thermosiphon reactor. This thermosiphon reactor exposed the alloy coupons to non-isothermal conditions expected in CSP plants. Cathodic protection was also added to the model as a mitigation strategy for corrosion of metal surfaces. The model …
-
Análise do desempenho térmico de um sistema de aquecimento solar de baixo custo
… The system operates under natural convection or thermosiphon. The absorbing surface of the collector is formed by twelve PVC pipes of 25 mm outside diameter connected in parallel via connections in T of the same material. The tubes were covered with absorbing fins made with recycled aluminum …
-
Viabilidades térmica, econômica e de materiais de um sistema solar de aquecimento de água a baixo custo para fins residenciais
… the conventionally. Its regimen of work is the thermosiphon for a volume of 250 liters water. The main characteristic of the system in considered study is its low cost, allowing a bigger socialization of the use of solar energy. It will be demonstrated the viabilities thermal, economic and of …
-
Projeto, construção e análise de desempenho de coletores solares alternativos utilizando garrafas pet
… for water heating is presented. It work on a thermosiphon, consisting of one or two alternative collectors and a water storage tank also alternative, whose main purpose is to socialize the use of energy mainly to be used by people of low income. The collectors were built from the use of pets …
-
Estudo térmico de um sistema solar de aquecimento de água residencial para duas configurações de superfície absorvedora
… absorption of sunlight. The system worked on a thermosiphon assembly and absorber of the collector has been tested in two configurations: with the tubes facing up, directly exposed to the impact of sunlight and facing down, exchanging heat with the plate by conduction. It was determined the most …
-
Análise do desempenho térmico de um sistema de aquecimento solar utilizando coletor com superfície absorvedora em chapas de PVC
… and beers cans open. The system worked on a thermosiphon and was tested in two configurations: the plates uncoated and coated with aluminum material, to determine the influence of material on the efficiency of the collector. For both configurations was used EPS plates below the surface to …
-
Feedforward control of binary distillation
… A total condenser provided the reflux, and a thermosiphon reboiler provided the stripping vapor. Analyses were made by refractive index measurements. The transient distillate and bottoms compositions were determined as responses to pulsed variations of feed composition, reflux rate and boilup …
-
Passive Energy Design for Schools in the Constantine Region of Algeria
… mass storage in conjuction with a passive solar thermosiphon loop could avoid winter overheating and fulfil the morning preheat demand, while summer cooling could be met using the same store and delivery system, but separate passive cool air intake and hot exhaust.
Page 1 of 2