Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"Thermosiphon loop"”.

  1. CPU Cooling in Data Center Using a Thermosiphon Loop with Tapered Open Microchannel Manifold (OMM)

    … cost to the system. The great potential of a thermosiphon system as a replacement of currently used cooling techniques is studied in the presented work. A thermosiphon loop using two-phase heat and mass transfer process uses latent heat of the working fluid. The latent heat is much more …

    rit Repository record for CPU Cooling in Data Center Using a Thermosiphon Loop with Tapered Open Microchannel Manifold (OMM) (opens in a new tab)

  2. A Thermosiphon Loop for High Heat Flux Removal using Flow Boiling of Ethanol in Open Microchannel Manifold (OMM) with Taper

    … in developing a low pressure drop system like a thermosiphon loop. To this end, a gravity-driven flow boiling system developed earlier was tested at low flow rates using ethanol. Based on the pressure drop and heat transfer data, a two-phase thermosiphon loop with a small ethanol head below 0.2 m …

    rit Repository record for A Thermosiphon Loop for High Heat Flux Removal using Flow Boiling of Ethanol in Open Microchannel Manifold (OMM) with Taper (opens in a new tab)

  3. High Heat Flux Dissipation Using Innovative Dual Tapered Manifold in Pool Boiling, and Thermosiphon Loop for CPU Cooling in Data Centers

    … tapered microgap design is also implemented in a thermosiphon loop for CPU cooling where no pumping power is required for fluid circulation in a closed loop. The loop contains an evaporator with a dual tapered microgap and was able to dissipate heat from an actual CPU (i7-930 processor, TDP 130W) …

    rit Repository record for High Heat Flux Dissipation Using Innovative Dual Tapered Manifold in Pool Boiling, and Thermosiphon Loop for CPU Cooling in Data Centers (opens in a new tab)

  4. BATTERY POWERED PORTABLE VAPOR COMPRESSION CYCLE SYSTEM WITH PCM CONDENSER

    … by using the vapor compression cycle as a thermosiphon loop. The main focus of the current research was on the development of the cooling system. The cooling capacity of the vapor compression cycle measured was 165.6 W with system COP at 2.85. It was able to provide 2 hours cooling without …

    maryland Repository record for BATTERY POWERED PORTABLE VAPOR COMPRESSION CYCLE SYSTEM WITH PCM CONDENSER (opens in a new tab)

  5. Passive Energy Design for Schools in the Constantine Region of Algeria

    … mass storage in conjuction with a passive solar thermosiphon loop could avoid winter overheating and fulfil the morning preheat demand, while summer cooling could be met using the same store and delivery system, but separate passive cool air intake and hot exhaust.

    glasgow Download PDF for Passive Energy Design for Schools in the Constantine Region of Algeria (opens in a new tab)

  6. Evaluation of Energy and Airflow Performance of Data Centers with Centralized Thermosiphon

    … an indirect airside free cooling based on thermosiphon loop is proposed and investigated to reduce energy consumption and improve the IT equipment reliability in a novel vertical data center (VDC) which is designed by Vert.com Inc. An energy model was established to evaluate the energy …

    concordia Download PDF for Evaluation of Energy and Airflow Performance of Data Centers with Centralized Thermosiphon (opens in a new tab)