Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 91 for “"Three Phase Power"”.
-
Differential Protection for Arbitrary Three-Phase Power Transformers
… current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use of standard transformer differential protection …
-
Coherent noise rejection in a three-phase power inverter
… reject the effects of high order harmonics in a three-phase power inverter. Specifically, coherent noise in the fifth harmonic is considered, as it seems to be dominant in most applications. The controller used in this power inverter operates in a reference frame synchronous with the 60 Hz line …
-
Three-phase power conversion using soft-switching PWM techniques
… related to high-frequency soft-switching PWM three-phase power converters. These are: 1. Analysis, synthesis, and design of three-phase soft-switching PWM power converter topologies 2. Design of input EMI filters for three-phase converters 3. Design of microprocessor controllers for …
-
Passive Component Weight Reduction for Three Phase Power Converters
… there has been increased use of electronic power processing in alternative, sustainable, and distributed energy sources, as well as energy storage systems, transportation systems, and the power grid. Three-phase voltage source converters (VSCs) have become the converter of choice in many ac …
-
Three-Phase Power Converter Based Real-Time Synchronous Generator Emulation
<p>To bridge the gap between power system research and their real application in power grids, a Hardware Test-Bed (HTB) with modular three-phase power converters has been developed at the CURENT center, the University of Tennessee, Knoxville, to emulate transmission level power systems with actual …
-
EM-Taguchi-PSO design optimization of three-phase power transformers
Power Transformers are an essential part of all AC Power Grids. This work proposes a multi-objective design optimization method for Power Transformers to increase efficiency while decreasing core volume in a case study of a step-down transmission-voltage transformer. A Finite-Element State-Space …
-
Synchronized Phasor Measurement Units Applications in Three-phase Power System
… in the field of real-time monitoring of power system. By aligning time stamps of voltage and current phasor measurements, which are consistent with Coordinated Universal Time (UTC), a coherent picture of the power system state can be achieved through either direct measurements or simple …
-
Versatile Three-Phase Power Electronics Converter based Real-time Load Emulators
… In the development, current controlled three-phase power electronics converter based emulator unit is adopted to create desired power system loading conditions.</p> <p>In the application, constant impedance, constant current and constant power (ZIP) load has been emulated to represent …
-
An analytical solution of subsequent faults in three-phase power systems
Thesis (M.S.)--Michigan State College of Agriculture and Applied Science. Dept. of Electrical Engineering, 1953
-
Component Modeling and Three-phase Power-flow Analysis for Active Distribution Systems
… a novel, fast, and accurate 3 steady-state power-flow analysis (PFA) tool for the real-time operation of the active distribution systems, also known as the active distribution networks (ADN), in the grid-tied and islanded operating modes. Three-phase power-flow models of loads, transformers, …
-
Three-Phase Power Factor Correction Circuits for Low-Cost Distributed Power Systems
Front-end converters with power factor correction (PFC) capability are widely used in distributed power systems (DPSs). Most of the front-end converters are implemented using a two-stage approach, which consists of a PFC stage followed by a DC/DC converter. The purpose of the front-end converter is …
-
Advance Three Phase Power Factor Correction Schemes for Utility Interface of Power Electronic Systems
Modern power electronic systems operate with different voltage and/or frequency rating such as Adjustable speed drive, Micro Grid, Uninterruptable Power Supplies (UPS) and High Voltage DC Transmission Systems. To match power electronic systems with the mains supply, DC link converters are used. The …
-
Design of High-Density Filter Building Blocks for SiC-based Three-Phase Power Converters
… high-density and high-efficiency integration of power electronics systems. This being the result of relatively high switching frequencies (>10 kHz) compared to conventional Si IGBT counterparts, which reportedly can minimize the size of passive components such as DC-link capacitors and line …
-
Design, modeling and control of a 12.47 kV isolated three phase power factor correction rectifier
A novel three-phase rectifier with power factor correction feature is proposed for the medium voltage (MV) high power (HP) applications. A typical application is to use it as the front-end circuit to interface with power grid and supply the power to a customized load, including medium voltage …
-
Digital one-cycle control technique with grid voltage measurement applied to three-phase power factor corrected rectifiers and active power filters
… Control (DOCC) with grid voltage measurement to three-phase Power Corrected (PFC) Rectifier and Active Power Filter (APF). The use of grid voltage is explored in a generalized approach, by defining the influence of these measurements on harmonics, power factor and load limits. The compensation of …
-
Ανάλυση και έλεγχος ολοκληρωμένων συστημάτων μετατροπέων ισχύος - ηλεκτρικών μηχανών με εφαρμογές στην ηλεκτροκίνηση και τις ανανεώσιμες πηγές ενέργειας
… is addressed in the research field of control of power systems and more precisely in providing advanced methods for the analysis and control of electrical machines driven by power devices. Particularly, taking into account the accurate nonlinear models of the power converters and the electrical …
-
Low harmonic content three-phase-to-DC-conversion using AC-side switches and discontinuous conduction mode
The quality of AC power is affected by the large number of nonlinear loads, particularly power converter systems. One way of improving the power factor of AC-DC converters in the 3-100 kW power range is by using Pulse Width Modulation rectifiers with low effects on the mains. The three-phase Power …
-
Validation of popular nonsinusoidal power theories for the analysis and management of modern power systems
… are characteristic of modem electrical power systems. Technological advances such as that of the rapidly developing solid-state technology has accelerated the nonlinear loading of power systems. The thesis firstly reformulates and demonstrates multi-frequency power system analysis …
-
AN INSTRUMENT FOR REAL-TIME MEASUREMENTS IN ELECTRIC POWER SYSTEMS
… methods of measuring electrical parameters of a power system are based on electromechanical instruments. These electromechanical instruments suffer from inherent limitations common to all mechanical systems. In recent years, digital electronic techniques have been adapted to work with …
-
Determination of impulse generator setup for transient testing of power transformers using optimization-enabled electromagnetic transient simulation
… mechanisms of electrical devices in the power system. It is important to test the insulation strength of a device against these impulsive overvoltages. Usually, Marx generators are used to generate impulse waveforms for testing purposes. A novel approach is proposed to obtain resistor …
Page 1 of 5