Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 87 for “"Three storey"”.
-
Assessment of seismic behavior of full-scale instrumented buildings using field data and calibrated numerical models
… of seismic responses of two instrumented three storey RC buildings under a selection of 50 earthquakes and behavioral changes after Ms=7.1 Darfield (2010) and Ms=6.3 Christchurch (2011) earthquakes for an instrumented eight story RC building. The dynamic characteristics of the instrumented …
-
Pramogų banko interjero įrangos projektas /
Designed interior of a three-storey modern building, located outside of Lithuania. However, proposed Project of Entertainment bank equipment designed for Lithuanian environment (selected plan for a major opened functional areas). New functional areas were replaced in the renovation: there were …
-
Numerical Investigations of the Indoor Thermal Environment in Atria and of the Buoyancy- Driven Ventilation in a Simple Atrium Building
… atria of two existing buildings and in a simple three-storey atrium building design have been undertaken using CFD techniques. The initial work involved the evaluation of various turbulence models and a radiation model used in CFD simulations for the prediction of the thermal environment in atria …
-
Strength of beam-columns in flexibly connected steel frames.
… tests, eight column subassemblages, and two three storey, two bay steel frames are reported. It is demonstrated that all beam to column connections have an inherent degree of stiffness and that their moment-rotation characteristics are non-linear. The load carrying capacity of columns, …
-
OPEN SPACE AND WALKUP APARTMENTS: A Case Study of User Needs and Landscape Design
… spaces and open space related elements in two three-storey walkup apartment complexes in Winnipeg. The study seeks to identify attitudes and patterns of use which can become the basis for a frame of reference for the design of this type of housing for residents of low to middle income. By …
-
Comparison of performance based engineering approaches
… structural response parameters, such as inter-storey drifts, as performance measures. This first generation PBEE is now being used by some engineers in the practicing community. However, most practicing engineers are unfamiliar with second generation PBEE, which focuses on economic loss. In …
-
Double Skin Facades Integrating Photovoltaic Panels, Motorized Shades and Controlled Air Flow
… and shading configurations for a south facing three-storey double skin façade considering a typical year in Montreal (Canada). Different flow rates inside the cavity and shading configurations were considered and simulated. It was concluded that the optimal cavity width, in which the …
-
Improvements to the Design and Use of Post-tensioned Self-centering Energy-dissipative (SCED) Braces
… upon the design and use of SCED braces through three large-scale experimental studies and an associated numerical building model study. The first experimental study increased the strength capacity of SCED braces and refined the design procedure through the design and testing of a new …
-
Room for Creativity; An Exploration of a new Timber Cultural Centre in central Gothenburg
… urban development. The project proposal is a three-storey cultural centre with an exposed timber load-bearing construction and an open spatial organisation intended to encourage movement, encounters, and interaction throughout the building. The architectural expression consists of three inner …
-
Seismic force redistribution in asymmetrical reinforced concrete buildings due to soil-structure interaction
… Interaction (SSI). A series of one-storey R/C plane frames with one, two and four spans, founded οn rigid, deformable soil through footings with connecting beams is analyzed dynamically. The seismic loading is simulated through synthetic accelerograms compatible with the EC8 design …
-
Modeling of existing and rehabilitated reinforced concrete buildings
… model was used in the analysis of an existing three-storey building to determine its seismic capacity. The effect of ignoring the beam-column joint shear deformations, bond slip and concrete crushing was studied. Ignoring any of these parameters can change the building failure mechanism which …
-
Development of a low damage steel frame building incorporating friction based braced and moment frame connections
… the design and detailing of a full scale, three storey steel framed test building with composite floor systems incorporating nine different seismic resisting systems, being the key part of the New ZealandChina RObust BUilding SysTem (ROBUST) project. These different systems are designed and …
-
Integrated modelling of structure-foundation systems
… foundation systems reduced the demands on three storey structures for all soil conditions. Increased structural demands were identified for the ten storey structure as a result of the reduced impact of foundation characteristics on the response of the integrated system. The level of …
-
Modeling and control of smart structures embedded with magnetorheological devices
… in the simulation of a seismically excited three-storey benchmark building model. To exploit the frequency domain advantage, this study also focuses on the cyclic dissipation of vibration-induced energy in the smart devices under a controlled magnetic field to analyze the energy …
-
A double-acting hydraulic ram pump for deep-well water pumping
… <p>A 15 m tall test facility housed within a three storey public stairwell was set up to help simulate pumping from deep underground. The DAHR sitting in a tank at the bottom would lift water to the top of the stairwell before it was returned under gravity to complete the circuit. The driving …
-
The Significance of Spaciousness: an investigation of spaciousness in the context of the residential yard
… was performed as a case-study with six cases. Three cases involve housing of low to medium density built during the urban building explosion of the 1960s known as “the Swedish million-program era”. They are typical of post-war multi-family housing with three-storey slab blocks. The other three …
-
Network-synthesis-based identification methodology for passive vibration suppression system design
… termed as 1PT1NG, IFL, 2PT1NG, GIFN networks. Three of them include one reaction mass, which can be represented through the use of a notional ground as the mass element does not have a direct electrical equivalent. The 1PT1NG network has one physical terminal (PT) and one notional ground (NG) …
-
Experimental investigations on seismic Behaviour of Light Timber framed Buildings and log-house traditional constructive System
… on crucial structural topics about multistorey timber construction. The efforts have been focused on the traditional light timber framed system (LTF) and on the log-house system (LH). Concerning the LTF, different aspects of the structural behaviour to the lateral load bearing structure …
-
The dynamic response of timber shear walls
This thesis describes three numerical models, developed by the author, that predict the behavior of timber shear walls. Two of the models have been implemented in finite element programs. One program predicts the static behavior of shear walls and the other predicts the dynamic response to …
-
Performance evaluation of friction damped braced steel frames under simulated earthquake loads
… objective is to study the performance of a 3 storey Friction Damped Braced Frame model under simulated earthquake loads. The main members of the test frame were chosen from available hot-rolled sections and the mass selected to provide the expected fundamental frequency of a three storey …
Page 1 of 5