Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"Three-phase currents"”

  1. Modified Space Vector Modulation for a Zero-Voltage Transition Three-Phase to DC Bi-directional Converter

    … algorithm for a zero-voltage transition three-phase voltage source inverter/boost rectifier is presented. The converter is intended for high performance medium power applications requiring bi-directional power flow. The proposed modified space vector modulation allows the main switches to …

    vt Repository record for Modified Space Vector Modulation for a Zero-Voltage Transition Three-Phase to DC Bi-directional Converter (opens in a new tab)

  2. Implementation of vector controlled induction motor drive using microcontroller

    … based on information from sensors, such as three phase currents from hall sensors, and one rotor speed from an optical encoder. The controller is operated in response to the speed references, which include step speed reference commands at the starting, and reversal speed reference commands …

    nanyang Repository record for Implementation of vector controlled induction motor drive using microcontroller (opens in a new tab)

  3. Physics informed temporal Koopman network for power converter fault diagnosis

    … for comparative experiments, which including three phase currents and voltages. Extensive experiments on the dataset show that PI-TKN outperforms the state-of-the-art (SOTA) models, achieving 95.25% accuracy, improving fault diagnosis performance in industrial power electronics.

    nanyang Repository record for Physics informed temporal Koopman network for power converter fault diagnosis (opens in a new tab)

  4. A Novel Inverter Based Resource Control Strategy to Facilitate Utility-Scale Renewable Integration and Retain Existing Transmission Protection Infrastructure

    … its pre-fault behavior of generating balanced three-phase currents. Transmission-line protective relays rely upon the unbalanced currents produced by synchronous generators to accurately determine the fault location. By controlling IBRs to emulate synchronous generator fault behavior, …

    umn Repository record for A Novel Inverter Based Resource Control Strategy to Facilitate Utility-Scale Renewable Integration and Retain Existing Transmission Protection Infrastructure (opens in a new tab)

  5. Advances in pulse width modulation techniques

    The phase angle control of the Two-Level Sinusoidal Pulse Width Modulation (SPWM) strategy has been studied in Part I of this thesis, and applied to a new voltage-source type PWM High Voltage Direct Current (HVDC) transmission system. The PWM-HVDC station exercises direct control over the voltage …

    mcgill Repository record for Advances in pulse width modulation techniques (opens in a new tab)

  6. A New Solution for Improving Transmission Line Distance Protection Security During System-Wide Cascading Failures

    … that uses local distance relay instantaneous three-phase currents to enhance the security of distance protection of transmission lines during wide-area cascading events. The method incorporates advanced signal processing techniques and pattern recognition approaches to prevent zone 3 distance …

    tamu Repository record for A New Solution for Improving Transmission Line Distance Protection Security During System-Wide Cascading Failures (opens in a new tab)

  7. Active Cooling of Traction Machine via Oil-Jet Impingement: Design & Experimentation

    … and a host-target inverter control forced fixed three-phase currents to produce repeatable thermal loading. Thirteen embedded thermocouples (windings, housing, drains) provided spatial temperature data, while DC-power logging enabled an energy-balance cross-check. Heat removal was quantified by …

    ohiolink Repository record for Active Cooling of Traction Machine via Oil-Jet Impingement: Design & Experimentation (opens in a new tab)

  8. Modeling and recognition of faults in smart distribution grid using maching intelligence technique

    … to the IEEE 13 Node Test Feeder to produce three phase currents and voltages as data set for this study. This was realized by modelling the IEEE 13-node benchmark test feeder in MATLAB-Simulink R2017a. In order to achieve intelligent fault recognition and fault-type identification, different …

    dut Repository record for Modeling and recognition of faults in smart distribution grid using maching intelligence technique (opens in a new tab)

  9. Machine learning implementation in electrical machine modelling and fault diagnosis

    … space-vector current sorting’ to convert three-phase currents into distinctive sequence-like patterns, which are then classified by a compact one-dimensional convolutional neural network (1D-CNN). Extensive offline tests, robustness analyses and real-time experiments confirm high …

    whiterose Repository record for Machine learning implementation in electrical machine modelling and fault diagnosis (opens in a new tab)

  10. DIRECT AND INDIRECT TORQUE CONTROL OF UNBALANCED PERMANENT MAGNET SYNCHRONOUS MACHINES

    … and flux ripples, acoustic noise, unbalanced three-phase currents, while also reducing efficiency. These types of imbalances and undesirable harmonic distortions cannot be controlled by using the conventional indirect torque control (ITC) and direct torque control (DTC) strategies. For some …

    whiterose Repository record for DIRECT AND INDIRECT TORQUE CONTROL OF UNBALANCED PERMANENT MAGNET SYNCHRONOUS MACHINES (opens in a new tab)

  11. Analysis of the integration of renewable energy and energy storage systems in series-cascaded microgrids

    … for inter-cluster power routing and symmetrical three-phase currents. The proposed framework determines optimal third-harmonic current, third-harmonic voltage, and zero-sequence injection, together with proportional DC-side power utilization control. Under adverse operating conditions, the …

    barcelona Repository record for Analysis of the integration of renewable energy and energy storage systems in series-cascaded microgrids (opens in a new tab)

  12. EXPERIMENTAL INVESTIGATIONS ON VIBRATIONS AND ACOUSTIC NOISE OF AN INDUCTION MOTOR

    … electromagnetic forces, which are created by the three-phase currents. The effects of impressed voltage and the change ofload on vibration levels are also investigated. Noise measurements are conducted in both an ordinary laboratory and an anechoic chamber. The ordinary laboratory is similar to …

    sask Repository record for EXPERIMENTAL INVESTIGATIONS ON VIBRATIONS AND ACOUSTIC NOISE OF AN INDUCTION MOTOR (opens in a new tab)

  13. Power Converters and Control for Grid Connected Microgrids under Unbalanced Operating Conditions

    … operational conditions for MGs, due to single phase loads and single phase generation units, the power exchange between MGs and the main grid will add negative effects to the main grid. Since the MG is supposed to be grid friendly when connected to the external grid, the unbalanced currents …

    catania Repository record for Power Converters and Control for Grid Connected Microgrids under Unbalanced Operating Conditions (opens in a new tab)

  14. Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid

    … asymmetrical loads draw distorted unbalanced currents and voltages at the point of common coupling (PCC) which propagate into the distribution network. Power quality has therefore become an important issue, which has resulted in the development of numerous control strategies and other …

    cape-town Repository record for Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid (opens in a new tab)

  15. Fault Tolerant Strategies for Modular Multilevel Converter Systems

    … faults (OCFs) within submodules (SMs) in the phase leg of MMCs, and 2) a system-level fault involving the complete loss of MMC phase leg(s). The proposed FDL and FT strategies are validated through both experimental setups and real-time simulation environments. Firstly, a new FDL scheme based …

    alberta Repository record for Fault Tolerant Strategies for Modular Multilevel Converter Systems (opens in a new tab)

  16. Modélisation et réglage d'un entraînement à haute performance par un moteur réluctant

    Usually, each phase of the direct reluctance motor is fed separately by its own inverter producing a squarewave phase current depending on the rotor position. In the present work, a star-connection of the three stator phases is used and the direct reluctance motor is fed by a three-phase switched …

    epfl Repository record for Modélisation et réglage d'un entraînement à haute performance par un moteur réluctant (opens in a new tab)

  17. Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors

    … of SITFs, fault severity evaluation, and faulty phase identification for line-connected induction motors. A novel two-dimensional (2D) convolutional neural network (CNN)-based SITF detection technique is first proposed, where the fundamental frequency phasor magnitude (FPM) and the third harmonic …

    sask Repository record for Advanced Stator Inter-Turn Fault Diagnosis Methods for Line-Connected Induction Motors (opens in a new tab)

  18. Dynamic Power System Load -Estimation of Parameters from Operational Data

    … been investigated based on field measurements of phase-to-phase faults in a non-effectively earthed 50 kV system in Sweden. Three-phase currents and voltages have been used to estimate the active and reactive power. The recordings exhibited voltage dips up to 30% in the positive sequence voltage. …

    lund Repository record for Dynamic Power System Load -Estimation of Parameters from Operational Data (opens in a new tab)

  19. Integrated on-board battery chargers for EVs based on multiphase machines and power electronics

    … this area. Possibilities of charging from single-phase and three-phase mains were both considered. In the former group the charging power rating cannot exceed the limit set by the single-phase mains. Therefore, the topologies are characterised with low charging powers, leading to a long duration …

    liverpool-jm Repository record for Integrated on-board battery chargers for EVs based on multiphase machines and power electronics (opens in a new tab)

  20. Directional Sub-Cycle Fault Detection On Systems Containing Inverter-Based Resources

    … analysis of the Lissajous curves traced by the three phase currents measured at two different points on the system to determine the presence and direction of faults on the system. Finally the hardware implementation of these protection schemes is shown on the Cyclone IV-E FPGA, with a wide range …

    sask Repository record for Directional Sub-Cycle Fault Detection On Systems Containing Inverter-Based Resources (opens in a new tab) Embargoed until 2027-12-18

Page 1 of 2