Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 38 for “"Threshold Limit Value"”

  1. Fungal Exposure and Development of Autoimmune Disorders

    … to fugal exposure, no standardized exposure limits or threshold limit value has been established yet. The nature and ubiquity of fungal materials makes it difficult to study exposure-disease relationships.

    ohiolink Repository record for Fungal Exposure and Development of Autoimmune Disorders (opens in a new tab)

  2. Evaluation of flash and fluorescent sources with respect to recommended ocular exposure thresholds

    … with respect to recommended ocular exposure limits. This system consists of a diode array radiometer calibrated for absolute radiometric measurements and software for the application of the currently accepted threshold limits for exposure to the various wavelengths of radiation. Absolute …

    rit Repository record for Evaluation of flash and fluorescent sources with respect to recommended ocular exposure thresholds (opens in a new tab)

  3. ΕΚΤΙΜΗΣΗ ΤΟΥ ΚΙΝΔΥΝΟΥ ΧΡΟΝΙΑΣ ΕΚΘΕΣΗΣ ΣΤΟΝ ΥΔΡΑΡΓΥΡΟ ΓΙΑ ΤΟΝ ΚΛΙΝΙΚΟ ΟΔΟΝΤΙΑΤΡΟΚΑΙ ΤΟ ΒΟΗΘΗΤΙΚΟ ΠΡΟΣΩΠΙΚΟ

    … THE EXAMINED GROUP. MERCURY CONCENTRATIONS ABOVE THRESHOLD LIMIT VALUE (0,05 MGHG/M3 OF AIR) HAVE BEEN DETERMINED IN THE ATMOSPHERE OF ABOUT 14% OF PRIVATEDENTAL OFFICES AND 28% OF THE -IKA- POLYCLINICS. ALSO A CLOSE RELATIONSHIP WAS REVEALED BETWEEN SOME DENTAL PRACTICE CHARACTERISTICS AND THE …

    greece Repository record for ΕΚΤΙΜΗΣΗ ΤΟΥ ΚΙΝΔΥΝΟΥ ΧΡΟΝΙΑΣ ΕΚΘΕΣΗΣ ΣΤΟΝ ΥΔΡΑΡΓΥΡΟ ΓΙΑ ΤΟΝ ΚΛΙΝΙΚΟ ΟΔΟΝΤΙΑΤΡΟΚΑΙ ΤΟ ΒΟΗΘΗΤΙΚΟ ΠΡΟΣΩΠΙΚΟ (opens in a new tab)

  4. An investigation into visual problems of crane operators at a petrochemical factory and the possible link with exposure to hydrocarbons

    … 0 to 0.477 ppm. These levels are well below the threshold limit value (TLV) for toluene which is 50ppm. Hydrocarbon levels were also determined by biological monitoring. The levels of hippuric acid/g creatinine and ortho-cresol/ g creatinine in the urine were also lower than the threshold values. …

    nwu-za Repository record for An investigation into visual problems of crane operators at a petrochemical factory and the possible link with exposure to hydrocarbons (opens in a new tab)

  5. The Ability of the U.S. Army Heat Strain Decision Aid (HSDA) to Predict a Limiting Heat Stress Exposure

    Working below the threshold limit value (TLV) for heat stress is not always feasible. When work above the TLV is required, an exposure method is needed that can help protect workers from time limiting heat stress by calculating a safe time for work at certain heat exposures. The purpose of this …

    usf Repository record for The Ability of the U.S. Army Heat Strain Decision Aid (HSDA) to Predict a Limiting Heat Stress Exposure (opens in a new tab)

  6. Heat stress, heat strain, and productivity in Washington State tree fruit harvesters

    … guidelines, which recommend thermal Action Limits and Threshold Limit Values based on several factors, including environmental conditions, metabolic rate of task, and clothing ensembles. Heat exposure was measured near individual workers using hand-held Wet Bulb Globe Temperature (WBGT) …

    washington Repository record for Heat stress, heat strain, and productivity in Washington State tree fruit harvesters (opens in a new tab)

  7. USE OF AIR DISPERSION MODELING TO ESTIMATE THE TIME POTENTIALLY AVAILABLE FOR EMERGENCY RESPONSE ACTION NEEDED TO PROTECT PUBLIC SAFETY FROM CHEMICAL RELEASES

    … to occupational exposure, Permissible Exposure Limit (PEL), Threshold Limit Value (TLV), and Immediately Dangerous to Life or Health (IDLH). The distance the plume traveled, used in conjunction with the time frame in which it moved, was used to determine the amount of time available to notify …

    ohiolink Repository record for USE OF AIR DISPERSION MODELING TO ESTIMATE THE TIME POTENTIALLY AVAILABLE FOR EMERGENCY RESPONSE ACTION NEEDED TO PROTECT PUBLIC SAFETY FROM CHEMICAL RELEASES (opens in a new tab)

  8. Protective laboratory measures for the flexible wall permeameter and the Atterberg limits tests using hazardous and toxic chemicals

    … the Flexible Wall Permeameter and the Atterberg Limits Tests. The tests were evaluated in detail to determine the critical points at which the technician would be exposed to the hazardous and/or toxic permeant. It was found that the following safety measures should always be taken; 1) the …

    njit Repository record for Protective laboratory measures for the flexible wall permeameter and the Atterberg limits tests using hazardous and toxic chemicals (opens in a new tab)

  9. Occupational noise exposure and hearing assessment of hydraulic fracturing workers: quiet versus conventional fleets

    … shift to determine if there were temporary threshold shifts (TTS) in hearing. Based on the personal noise dosimetry results, 42/50 (84%) of the quiet fleet and 34/34 (100%) of the conventional fleet workers sampled were at or over 100% noise dose according to the American Conference of …

    colostate Repository record for Occupational noise exposure and hearing assessment of hydraulic fracturing workers: quiet versus conventional fleets (opens in a new tab)

  10. An Exposure Assessment of Paper Dust in a Coupon Manufacturing Facility

    … Administration (OSHA) Permissible Exposure Limit (PEL) and 0.5% to 7.1% of the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV), except sample RD-4 in the Baler Room. TWAs for respirable dust within the Press Room and Collation Area ranged from …

    usf Repository record for An Exposure Assessment of Paper Dust in a Coupon Manufacturing Facility (opens in a new tab)

  11. Assessment of Occupational Heat Strain

    … rate were 5°CWBGT and 10°C-WBGT above the Threshold Limit Value adjusted for clothing. Eight male and four female acclimated individuals (age 18-36 years) participated. Four experimental trials were randomized in sequence. The transition point, when a participant’s status changed from …

    usf Repository record for Assessment of Occupational Heat Strain (opens in a new tab)

  12. Exposure of car guards to solar ultraviolet radiation during summer and winter

    … that of other anatomical areas, even though values were in excess of the threshold limit value (TLV). Heat stress measurements obtained during summer indicated a WBGTo ranging between 22.60 - 30.94, and that of winter ranged between 8.32 - 20.32. Conclusion: The high exposure of car guards to …

    nwu-za Repository record for Exposure of car guards to solar ultraviolet radiation during summer and winter (opens in a new tab)

  13. Evaluation Of Occupational Exposure To Noise And Respirable Particulate Matter In Dentistry

    … exposures are common in dental environments, limited data exist describing full-shift occupational exposure levels during routine dental procedures. The purpose of this study was to evaluate occupational exposure to noise and respirable particulate matter (RPM) during routine dental procedures …

    uab Repository record for Evaluation Of Occupational Exposure To Noise And Respirable Particulate Matter In Dentistry (opens in a new tab)

  14. Potential Noise Exposure During Post-Trip Inspection Among Commercial Freight Truck Operators

    … Administration’s (OSHA) permissible exposure limit (PEL) and Hearing Conservation (HC) action level in addition to the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV). 4 trucks were sampled and for each truck, recording duration lasted …

    uab Repository record for Potential Noise Exposure During Post-Trip Inspection Among Commercial Freight Truck Operators (opens in a new tab)

  15. Noise exposure and evaluation at tire changing facilities

    … without exceeding occupational exposure limits. Personal noise dosimetry data were compared to published occupational noise exposure limits to assess compliance. The noise dosimetry results were then extrapolated against the number of tire changes to determine if there was a relationship …

    colostate Repository record for Noise exposure and evaluation at tire changing facilities (opens in a new tab)

  16. Employee noise exposure and octave band analysis in a manufacturing setting

    … were compared to published occupational exposure limits to determine if they were at increased risk of hearing loss. Personal noise exposures were compared to the Occupational Safety and Health Administration's (OSHA) noise Action Level (AL) and Permissible Exposure Limit (PEL); the American …

    colostate Repository record for Employee noise exposure and octave band analysis in a manufacturing setting (opens in a new tab)

  17. Acute respiratory effects and endotoxin exposure during wheat harvest in northeastern Colorado

    … with 8 percent of workers exposed above the threshold limit value of 4 mg/m3. Total endotoxin exposures ranged from 4.4 to 744.4 EU/m3 (geometric mean 54.2 EU/m3), with 33 percent of workers exposed above levels associated with symptoms and lung function effects. At these exposure levels, 60 …

    colostate Repository record for Acute respiratory effects and endotoxin exposure during wheat harvest in northeastern Colorado (opens in a new tab)

  18. Entwicklung der Narkosegasbelastung des Anästhesie-Personals der Universitätsklinik Freiburg von 1992 - 2001

    An der Anästhesiologischen Universitätsklinik der Albert-Ludwigs-Universität werden seit 1992 regelmäßige Messungen der Narkosegasbelastung in den Arbeitsbereichen der Anästhesie durchgeführt. Die Narkosegasmessungen werden nach Vorgabe der Gefahrstoffverordnung vorgenommen und von so genannten …

    freiburg-diss Repository record for Entwicklung der Narkosegasbelastung des Anästhesie-Personals der Universitätsklinik Freiburg von 1992 - 2001 (opens in a new tab)

Page 1 of 2