Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"Tibia fracture"”.
-
Engineered mRNA therapeutic encoding beta-catenin increased bone formation in a murine tibial fracture model
Fractures continue to be a global economic burden and impaired fracture healing cases, like delayed and non-union, occurring in about 14% of all tibial shaft fractures. Current treatments to aid in fracture healing involve surgical interventions and osteoanabolic, bone-morphogenetic protein-2 …
-
A Study of Knee Injury Mechanisms in Car-to-Pedestrian Impacts Using
… structures, upper body mass and presence of tibia fracture on the calculated injury parameters was investigated using total 24 simulations. The LLMS model was refined and evaluated using published cadaver test data. Six simulations of bumper-to-lower extremity impacts were carried out under …
-
Πειραματική μελέτη της σταθερότητας της ενδομυελικής ήλωσης ασταθών καταγμάτων κνήμης με περιφερικούς κοχλίες διαφορετικού αριθμού και θέσης
Recently introduced tibial intramedullary nails allow a multitude of distal screws to be used in order to reduce the incidence of mal-alignment and loss of fixation of distal metaphyseal fractures. However, the number of screws and the type of screw configuration to be used remains obscure. In …
-
Amputation rate following tibia fractures with associated popliteal artery injuries
… and 2. identify risk factors in patients with tibia fractures and associated popliteal artery injuries. Intervention: Amputation or limb salvage. Design: Retrospective case-control study. Setting: Level 1 trauma center. Patients: Thirty popliteal artery injuries with ipsilateral tibial …
-
Prognosis and Management of Patients who had Trauma Necessitating Orthopedic Surgeries
… of antibiotic prophylaxis in patients with open fracture of the extremities. The results demonstrate moderate quality evidence of an important reduction in the infection rate in patients receiving, versus not receiving, antibiotic prophylaxis. We found no difference in infection rate with longer …
-
Characterizing Distal Tibia Fractures in Motor Vehicle Crashes: Assessing Occupant Risk, Vehicle Crashworthiness, and Clinical Outcomes
High-energy distal tibia fractures are a clinically complex injury associated with high rates of clinical complications, chronic pain, and functional limitations. One of the primary causes of severe distal tibia fractures are motor vehicle crashes. Road traffic injuries account for a significant …
-
Immunomodulation of IL6 transsignaling in polytrauma
… were assigned to one of three study arms, sham, fracture or polytrauma. The mice were given general anaesthesia and received an ipsilateral femur- and tibia fracture (fracture group), a haemorrhagic shock in addition to the fractures (polytrauma group), or no further intervention (sham group). …
-
Exploring Prognostic Factors Associated with Adverse Outcomes in Patients with Fractures of the Tibial Shaft
… indicators for complications in patients with fractures of the tibial shaft. In particular, the complications of focus in this thesis are surgical site infections and nonunion. The three analytical studies comprising this thesis were derived from large data sets arising from two randomized …
-
Εκτίμηση της σταθερότητας της κεντρικής ασφάλισης του ενδομυελικού ήλου στα κατάγματα του άνω τριτημορίου της κνήμης
… is the gold standard treatment of diaphyseal fractures of the tibia. As a result of this gain in popularity, the indications for intramedullary nailing have expanded to more proximal fracture patterns. However, when the same method is used for extra-articular fractures of the proximal tibia, …
-
ΑΝΤΙΜΕΤΩΠΙΣΗ ΤΩΝ ΑΝΟΙΚΤΩΝ ΚΑΤΑΓΜΑΤΩΝ ΤΗΣ ΚΝΗΜΗΣ ΜΕ ΤΗ ΧΡΗΣΙΜΟΠΟΙΗΣΗ ΕΞΩΤΕΡΙΚΗΣ ΟΣΤΕΟΣΥΝΘΕΣΕΩΣ ΕΙΔΙΚΟΥ ΚΑΙ ΣΥΓΧΡΟΝΟΥ ΤΥΠΟΥ
… STUDY IS THE ANALYSIS OF THE RESULTS OF THE OPEN TIBIA FRACTURES TREATMENT, WITH A DYNAMIC AXIAL FIXATOR. IN THIS STUDY WE REPORT 65 PATIENTS WITH AN OPEN TIBIAL FRACTURE. 78,5% OF THEM SUSTAINED A GRADE THREE OPENFRACTURE. ALL THESE FRACTURES WERE TREATED WITH AN ORTHOFIX EXTERNAL FIXATION DEVICE …
-
ΜΕΙΟΝΕΚΤΗΜΑΤΑ ΚΑΙ ΠΛΕΟΝΕΚΤΗΜΑΤΑ ΤΩΝ ΜΕΘΟΔΩΝ ΑΝΤΙΜΕΤΩΠΙΣΗΣ ΤΩΝ ΚΑΤΑΓΜΑΤΩΝ ΤΗΣ ΔΙΑΦΥΣΗΣ ΤΗΣ ΚΝΗΜΗΣ (ΑΝΑΛΥΣΗ 360 ΚΑΤΑΓΜΑΤΩΝ)
… IN TREATING 351 PATIENTS WITH 360 DIAPHYSEAL FRACTURES OF THE TIBIA, USING CONSERVATIVE AND SURGICAL METHODS. WE ANALYSE THE RESULTS OF CONSERVATIVE TREATMENT (PLASTER OF PARIS) WITH THOSE OF SURGICAL ONES (PLATES AND SCREWS, EXTERNAL FIXATION AND ESPECIALLY THE INTRAMEDULLARY NAILING) IN …
-
Histologische Untersuchung der Frakturheilung Ein Vergleich von unaufgebohrter Marknagelung und Fixateur intern Stabilisierung in einer tierexperimentellen Studie an der Schafstibia
… einfachen Schaftfraktur der Schafstibia mit standardisiertem Weichteiltrauma im lateralen Kompartiment (Grad II nach Tscherne) durchgeführt. Jedes Schaf wurde an beiden Hinterläufen operiert und mit einem Fixateur intern (PC Fix II Mathys, Schweiz) bzw. einem unaufgebohrten …