Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 33 for “"Tibial Component"”

  1. Assessing and improving clinical outcomes of the cementless Oxford unicompartmental knee replacement tibial component

    … cemented, but have a higher incidence of early tibial fracture, and is not known how their symptoms compare. The aims of this thesis were firstly to compare the symptoms following cemented and cementless OUKR and explore factors that may influence them, and secondly to assess design changes …

    oxford Repository record for Assessing and improving clinical outcomes of the cementless Oxford unicompartmental knee replacement tibial component (opens in a new tab)

  2. Parameter establishment for the design of interference fit tibial component of total knee replacement

    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] Over 4.7 million Americans are living with total knee replacements with an additional one million receiving the surgery each year. With these numbers predicted to grow each year, there is a need for a more robust and …

    missouri Repository record for Parameter establishment for the design of interference fit tibial component of total knee replacement (opens in a new tab)

  3. Effect of unicompartmental knee replacement tibial component design on proximal tibial strain and ongoing pain

    … a possible cause of which is elevated proximal tibial bone strain. The influence of implant design on this strain has not been previously investigated. Aims: The aims of this thesis are to determine the effect of medial UKR tibial component design on proximal tibial strain and ongoing pain. …

    edinburgh Repository record for Effect of unicompartmental knee replacement tibial component design on proximal tibial strain and ongoing pain (opens in a new tab)

  4. Three dimensional finite element analysis of a tibial ankle prosthesis

    … and compare partially and fully porous coated tibial components, of an ankle prosthesis, implanted in the distal tibia. The geometry of the distal tibia is determined from measurements of cross sections of a human tibia. From the measurements, solid models of the cancellous and cortical bone …

    njit Repository record for Three dimensional finite element analysis of a tibial ankle prosthesis (opens in a new tab)

  5. Fixation of the Oxford unicompartmental knee replacement

    … radiolucent lines are commonly found beneath the tibial tray. With the projected increase in knee arthroplasty, particularly in younger patients, implant longevity is of paramount importance. The aim of this thesis is to understand how fixation is achieved with the Oxford UKR and how it can be …

    oxford Repository record for Fixation of the Oxford unicompartmental knee replacement (opens in a new tab)

  6. Outcome after medial unicompartmental knee replacement

    … had pain related complications.</p> <p>Although component and leg alignment, and component overhang have a profound effect on the outcome of total knee replacement (TKR), their effect on the outcome of the Oxford UKR are not known. It was found that malalignment in the coronal or sagittal planes …

    oxford Repository record for Outcome after medial unicompartmental knee replacement (opens in a new tab)

  7. Investigation of the effect of surgical factors on the transition from primary to secondary stability of press-fit components in the proximal medial tibia

    … long-term implant survival. The aetiology of tibial periprosthetic fracture (PPF) and tibial component subsidence which are two complications after OUKR associated with tibial component fixation were unknown.</p> <p>As primary stability of cementless components is related to the mechanical …

    oxford Repository record for Investigation of the effect of surgical factors on the transition from primary to secondary stability of press-fit components in the proximal medial tibia (opens in a new tab)

  8. Fixation of the cementless oxford unicompartmental knee replacement

    … There are, however, anecdotal reports of tibial plateau fractures with cementless fixation. The aim of this thesis was to assess the clinical outcome and key biomechanical aspects of the fixation of the cementless OUKR.</p> <p>A systematic review demonstrated that modern cementless …

    oxford Repository record for Fixation of the cementless oxford unicompartmental knee replacement (opens in a new tab)

  9. Μακροπρόθεσμα αποτελέσματα ολικής αρθροπλαστικής γόνατος με επικάλυψη υδροξυαπατίτη

    … damage, two for fatigue fracture of the tibial component and two for non-specific knee pain. Analysis of six retrieved and one unused set of knee arthroplasties showed local inconsistencies of the hydroxyapatite characteristics, with respect to coating thickness, adherence to metal and …

    greece Repository record for Μακροπρόθεσμα αποτελέσματα ολικής αρθροπλαστικής γόνατος με επικάλυψη υδροξυαπατίτη (opens in a new tab)

  10. Finite Element Analysis of the Proximal implanted Tibea in relation to implant loosening

    <p>Tibial component alignment is one of the parameters that have most influence on implant loosening. The effect of varus-valgus and antero-posterior angles on the cancellous bone stress at the bone-implant interface was examined by means of finite element analysis. The lowest stress was obtained …

    soton Repository record for Finite Element Analysis of the Proximal implanted Tibea in relation to implant loosening (opens in a new tab)

  11. Περιορισμένης επεμβατικότητας ολική αρθροπλαστική του γόνατος έναντι της κλασικής: συγκριτική μελέτη

    … No cases of malposition of either the femoral or tibial component were identified. Major general or local complications, radiological signs of implant loosening or displacement were not recorded during the follow up examination. In conclusion, MIS is a reliable and safe surgical technique in …

    greece Repository record for Περιορισμένης επεμβατικότητας ολική αρθροπλαστική του γόνατος έναντι της κλασικής: συγκριτική μελέτη (opens in a new tab)

  12. Biomechanical comparison of two total ankle replacement designs : micromotion and kinematic patterns

    … the bone and prosthesis than the STAR for the tibial component in INV-EV (p=0.037), and for the talar component in PF-DF (p=0.002) and IR-ER (p=0.038). Micromotion magnitudes were affected by loading direction and compression. Kinematic changes were observed following replacement of the ankle …

    ubc Repository record for Biomechanical comparison of two total ankle replacement designs : micromotion and kinematic patterns (opens in a new tab)

  13. Alergija metalui po kelio sąnario endoprotezavimo. Klinikinio atvejo pristatymas ir literatūros apžvalga /

    … right knee joint showed osteolysis around the tibial component, therefore, revision surgery was performed, during which microbiological cultures were taken and a positive Synovasure Alpha Defensin test was obtained. Due to a suspected infectious inflammation, cemented inserts were implanted. …

    vilnius Repository record for Alergija metalui po kelio sąnario endoprotezavimo. Klinikinio atvejo pristatymas ir literatūros apžvalga / (opens in a new tab)

  14. Degradation of Cobalt Chrome Molybdenum Hip And Knee Implants in Vivo and in Vitro

    … and material transfer from the backside of the tibial component onto the posterior condyle of the femoral component are more prevalent than originally thought. These damage modes, along with migration of alumina from grit blasted tibial components, allow for third body wear particles to enter …

    clemson Repository record for Degradation of Cobalt Chrome Molybdenum Hip And Knee Implants in Vivo and in Vitro (opens in a new tab)

  15. Μακροπρόθεσμα αποτελέσματα επιφανειακής ολικής αρθροπλαστικής γόνατος με ασύμμετρους κνημιαίους κονδύλους (GENESIS I)

    … cases. The prosthesis consisted of a femoral, a tibial component, a polyethylene insert and a polyethylene patella component. The femoral and the tibial components were placed with the use of cement. It is an easy-to-use system featuring an anatomic, chrome - cobalt femoral component with a wide, …

    greece Repository record for Μακροπρόθεσμα αποτελέσματα επιφανειακής ολικής αρθροπλαστικής γόνατος με ασύμμετρους κνημιαίους κονδύλους (GENESIS I) (opens in a new tab)

  16. Optimising the outcomes of the Oxford unicompartmental knee replacement

    … However the revision rate for peri-prosthetic tibial fracture increased. These results were mirrored by a systematic review comparing fixation types for all UKR types (n=10,736). </p> <p>Other retrospective observational studies from the NJR were used to investigate the effect on revision rates …

    oxford Repository record for Optimising the outcomes of the Oxford unicompartmental knee replacement (opens in a new tab)

Page 1 of 2