Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 56 for “"Timber connections"”.

  1. Reinforced multiple bolt timber connections

    Bolted connections have been used in heavy timber construction for centuries. Yet design rules are very inconsistent and failure modes are often of a brittle nature, contrary to design rules that are based on a yield model approach. To improve the ductility of bolted connections especially in …

    ubc Repository record for Reinforced multiple bolt timber connections (opens in a new tab) Download PDF for Reinforced multiple bolt timber connections (opens in a new tab)

  2. Fire Performance of Hybrid Timber Connections

    … Hybrid building systems involve the use of heavy timber in combination with other materials. A hybrid timber connection is considered as the weakest link in this construction system particularly under fire exposure. Analysis of hybrid timber connections is complicated because the behavior and …

    carleton Repository record for Fire Performance of Hybrid Timber Connections (opens in a new tab)

  3. Modelling the Fire Performance of Hybrid Steel-Timber Connections

    … building system. In this research, a steel-timber hybrid system is considered, which consists of a glulam wooden beam connected to a steel column. The connection of the beam to the column is composed of three different types of shear tab connections: concealed, exposed and seated …

    carleton Repository record for Modelling the Fire Performance of Hybrid Steel-Timber Connections (opens in a new tab)

  4. Probabilistic assessment of brittle failure modes of timber connections

    The growing popularity of timber as a building material fuelled by a increasing rise of both environmental and social sustainability is pushing timber structures to new heights. Taller and more complex timber structures are leading to higher capacity connections being required to continuing …

    chalmers Repository record for Probabilistic assessment of brittle failure modes of timber connections (opens in a new tab)

  5. Seismic retrofit of masonry-to-timber connections in historical constructions

    Proper structural connections play an important role in ensuring seismic loads distribution and developing global damage mechanisms of structures. In unreinforced masonry buildings, effective connections between masonry walls and timber floors or walls through the use of anchors can prevent the …

    minho-thes Repository record for Seismic retrofit of masonry-to-timber connections in historical constructions (opens in a new tab)

  6. Stiffness of dowel-type timber connections and its influence on structures Finite element analysis of high performance timber connections and their impact in a case study

    Timber is one of the oldest construction materials and are used for many purposes in the field. Although, timber has not been prioritized as a structural material for multi-storey buildings, today’s new technologies which generate engineering wood products, allow to build in larger scale than ever …

    chalmers Repository record for Stiffness of dowel-type timber connections and its influence on structures Finite element analysis of high performance timber connections and their impact in a case study (opens in a new tab)

  7. Numerical modelling approaches for dowelled timber connections based on fracture mechanics

    A ocorrência de roturas frágeis em ligações pode comprometer a estabilidade das estruturas de madeira. No entanto, faltam estratégias para avaliar esses modos de rotura e métodos de dimensionamento dos reforços para os evitar. Esta tese contribui com uma abordagem numérica com várias escalas, …

    minho-thes Repository record for Numerical modelling approaches for dowelled timber connections based on fracture mechanics (opens in a new tab) Embargoed until 2026-12-12

  8. Monotonic and cyclic short-term performance of nailed and bolted timber connections

    … two methods of fully reversing cyclic loading of connections are presented. The first method was a load-controlled test with the applied cyclic loads acting at specified percentages above current nominal design values. The sets of specimens were then ramped to failure and the results were compared …

    vt Repository record for Monotonic and cyclic short-term performance of nailed and bolted timber connections (opens in a new tab)

  9. Performance of timber connections with single and multiple glued-in threaded steel rods

    … of manufacturing defects on the capacity of timber joints with glued-in steel rods. For this purpose, timber joints were manufactured with two different types of defects likely to be encountered during their manufacturing on-site: i) rods placed at an angle to the drill hole instead of being …

    ubc Repository record for Performance of timber connections with single and multiple glued-in threaded steel rods (opens in a new tab) Download PDF for Performance of timber connections with single and multiple glued-in threaded steel rods (opens in a new tab)

  10. Full Scale Tests on the Performance of Hybrid Timber Connections in Real Fires

    Connections form an integral part of any building system. Concerns are raised when dealing with hybrid connections especially in fire. This is because different materials with varying ambient and thermal properties must perform together to ensure a stable structural system. This research seeks to …

    carleton Repository record for Full Scale Tests on the Performance of Hybrid Timber Connections in Real Fires (opens in a new tab)

  11. Additive Timber Jointing: Design and Robotic Manufacturing of Fiber-Aligned Mass Timber Connections

    Mass timber construction has been increasingly dependent upon connections that are manufactured independently from the structural members they will eventually be joining. This typically requires significant structural material removal to fabricate CNC-machined interfaces in glue-laminated and …

    oregon Repository record for Additive Timber Jointing: Design and Robotic Manufacturing of Fiber-Aligned Mass Timber Connections (opens in a new tab)

  12. Experimental investigations of residual and fatigue capacities of timber connections with glued-in FRP rods

    Well-designed and executed glued-in rod connections can provide excellent structural performance in terms of strength, stiffness, and efficiency in load transfer. The pull-out residual and fatigue capacity of timber connections with glued-in Glass Fibre Reinforced Polymer (GFRP) rods bonded by …

    ubc Repository record for Experimental investigations of residual and fatigue capacities of timber connections with glued-in FRP rods (opens in a new tab) Download PDF for Experimental investigations of residual and fatigue capacities of timber connections with glued-in FRP rods (opens in a new tab)

  13. Verification of an analytical hysteresis model for dowel-type timber connections using shake table tests

    … response of ductile dowel type moment-resisting connections. The analytical model, FRAME, is based on each dowel modelled as an elasto-plastic beam in a non-linear medium, thus allowing the formation of gaps between the beam and the medium. The model calculates the response using basic …

    ubc Repository record for Verification of an analytical hysteresis model for dowel-type timber connections using shake table tests (opens in a new tab) Download PDF for Verification of an analytical hysteresis model for dowel-type timber connections using shake table tests (opens in a new tab)

Page 1 of 3