  1. IMPROVED TECHNOLOGY FOR TIME DOMAIN MEASUREMENTS IN FLOW CYTOMETRY

    Flow cytometers that repeat measurements on individual samples are powerful tools enabling uncertainty quantification and other fundamentally new measurement schemes in cytometry. While this approach introduces new testing modes in cytometry, multi-region measurements in these systems increase …

    maryland Repository record for IMPROVED TECHNOLOGY FOR TIME DOMAIN MEASUREMENTS IN FLOW CYTOMETRY (opens in a new tab)

  2. Investigation of time-domain measurements for analysis and machine recognition of speech

    … and mechanical speech recognition work, spectral measurements are the conventional form of signal representation and acoustical descriptions of speech sounds are usually given in terms of this form of representation. In this thesis, certain time-domain measurements are investigated as an …

    ubc Repository record for Investigation of time-domain measurements for analysis and machine recognition of speech (opens in a new tab) Download PDF for Investigation of time-domain measurements for analysis and machine recognition of speech (opens in a new tab)

  3. Optical spectroscopy of turbid media: time-domain measurements and accelerated Monte Carlo modelling

    … scattering (turbid) materials by means of time-of-flight spectroscopy (TOFS). Instrumentation and modelling aspects of TOFS were investigated and improved, enabling significantly more accurate spectroscopic measurements. It was shown that the commonly used diffusion theory fails to …

    lund Repository record for Optical spectroscopy of turbid media: time-domain measurements and accelerated Monte Carlo modelling (opens in a new tab) Download PDF for Optical spectroscopy of turbid media: time-domain measurements and accelerated Monte Carlo modelling (opens in a new tab)

  4. Optical Fiber Dispersion Characterization

    … function of an optical fiber using either time domain measurements or frequency domain measurements are given. A test set is described which uses time domain measurements for dispersion characterization. Complex transfer function data are presented for various fiber lengths as well as …

    ucf Repository record for Optical Fiber Dispersion Characterization (opens in a new tab)

  5. InGaN šviestuko tyrimas mažo sužadinimo dažninės skyros metodu /

    … work I demonstrate the small signal frequency domain method for differential carrier lifetime measurements. This method allowed me to measure differential carrier lifetime in a broad normalized optical power range (0,04 – 25). The use of DLT technique simplified the carrier and photon number …

    vilnius Repository record for InGaN šviestuko tyrimas mažo sužadinimo dažninės skyros metodu / (opens in a new tab)

  6. The development of a bistatic electromagnetic scattering laboratory employing time domain measurement techniques for impulse response determination and target classification.

    A time domain measurements, electromagnetic has been developed to provide a means of exper the transient, scattered electromagnetic field objects for impulse response determination or The evolution of the physical laboratory is de the development of the transmitting and receiv interface of the data …

    nps Repository record for The development of a bistatic electromagnetic scattering laboratory employing time domain measurement techniques for impulse response determination and target classification. (opens in a new tab)

  7. Time domain metrology for dielectric spectroscopy of particulates

    … the permittivity of soil samples using measurements in the time domain were studied. A number of algorithms for inverting the measured data to obtain epsilon were investigated and three different types of sampling devices were examined. The investigation examined the positive and …

    vt Repository record for Time domain metrology for dielectric spectroscopy of particulates (opens in a new tab)

  8. Time domain transmission line measurements with the speedy delivery signal

    … Use of the SD waveform allows for high precision time domain measurements on transmission lines. High precision time domain reflectometry (TDR) and time domain transmission (TDT) measurements are described. An example measurement is presented. The design of the experimental apparatus is detailed. …

    texas Repository record for Time domain transmission line measurements with the speedy delivery signal (opens in a new tab)

  9. Multiple scattering of broadband terahertz pulses

    … have used narrowband optical radiation where measurements are limited to time averaged intensities or autocorrelation quantities, which contain no phase information of the pulses. In the experiments presented here, a terahertz time-domain spectrometer (THz-TDS) is used. A THz-TDS propagates …

    rice Repository record for Multiple scattering of broadband terahertz pulses (opens in a new tab)

  10. Phase-Locking Performance of Optical Injection-Locking Evaluated by Coherent Detection

    … performance of injection-locking, novel coherent time domain measurements has been conducted. Performance measurements are focused on phase variance in time domain. The results agree with theoretical work previously done by Bordonalli et al. Several tradeoffs are identified, amongst them, between …

    chalmers Repository record for Phase-Locking Performance of Optical Injection-Locking Evaluated by Coherent Detection (opens in a new tab)

  11. Spice modeling and simulation of silicon-carbide power modules

    … parasitic model of the power module’s frequency domain behavior. Second, double pulse testing is implemented to characterize the dynamic behavior of the power module. Next, a SPICE model is developed from the frequency and time domain measurements. Finally, the model is validated through its …

    alabama Repository record for Spice modeling and simulation of silicon-carbide power modules (opens in a new tab)

  12. Target detection via Kalman filtering

    A simple, time domain method is used to analyze moderate to high PRF radar signals. The quantities of interest are the signal's PRF, SNR, and time of arrival. The time of arrival problem is important because it can be used, with multiple sensors, to determine the position of the emitting target. An …

    nps Repository record for Target detection via Kalman filtering (opens in a new tab)

  13. Ultrafast and magneto-optical spectroscopy of semiconductor heterostructures

    … telluride for mid-infrared detection. Our time-domain measurements help sample growers optimize growth conditions to maximize the carrier lifetime and determine the superlattice period and interface quality. The second area of research has a more fundamental focus. Here, we study the …

    rice Repository record for Ultrafast and magneto-optical spectroscopy of semiconductor heterostructures (opens in a new tab)

  14. Interposer platforms featuring polymer-enhanced through silicon vias for microelectronic systems

    … and synchrotron x-ray diffraction (XRD) measurements have been demonstrated. High-frequency measurements up to 170 GHz and time-domain measurements up to 10 Gbps have been demonstrated for the fabricated polymer-embedded vias. For the fabricated coaxial vias and inductors, high-frequency …

    gatech Repository record for Interposer platforms featuring polymer-enhanced through silicon vias for microelectronic systems (opens in a new tab)

  15. Use of Pattern Classification Algorithms to Interpret Passive and Active Data Streams from a Walking-Speed Robotic Sensor Platform

    … attention is given to acoustic echolocation measurements of approaching vehicles, where an acoustic parametric array propagates an audible signal to the oncoming target and the Kinect microphone array records the reflected backscattered signal. Although useful information about the target is …

    wm-mary Repository record for Use of Pattern Classification Algorithms to Interpret Passive and Active Data Streams from a Walking-Speed Robotic Sensor Platform (opens in a new tab)

  16. The design of SiGe integrated circuit components for extreme environment systems and sensors

    … ultra-fast x-ray detector for picosecond scale time-domain measurements of evolving chemical reactions. The first two projects capitalized on the wide-temperature performance and radiation tolerance of the SiGe HBT, allowing them to operate under extreme environmental conditions reliably and …

    gatech Repository record for The design of SiGe integrated circuit components for extreme environment systems and sensors (opens in a new tab)

  17. Time-Domain Measurement Of Ultrafast Magnetization Dynamics In Magnetic Nanoparticles

    Ultrafast time-domain measurements are made on collections of Fe3O4 magnetic nanoparticles using an inductive measurement technique. The 10nm particles are placed directly on a coplanar waveguide (CPW) situated in an adjustable external magnetic bias field. A fast-rising step current in the CPW …

    south-carolina Repository record for Time-Domain Measurement Of Ultrafast Magnetization Dynamics In Magnetic Nanoparticles (opens in a new tab)

  18. Femtosecond time-resolved spectroscopy of coherent oscillations in nanomaterials

    … of the acoustic vibrations, obtained from the time-domain measurements with low intensity pump pulses, together with the information about the size of the particles, were used to determine the elastic constants of the materials. Also changes in the measured acoustical response of the Ag …

    tamu Repository record for Femtosecond time-resolved spectroscopy of coherent oscillations in nanomaterials (opens in a new tab)

  19. Time-Domain Measurement of Magnetization Dynamics in Ferrofluids

    Time-domain measurements are made on a magnetite-based (Fe3O4) ferrofluid using an inductive technique. The constituent particles are 5.8% by volume, polydisperse, and have a nominal diameter of 10nm with a ~1nm-thick anionic hydrophobic coating. The ferrofluid is placed in a sealed channel on a …

    south-carolina Repository record for Time-Domain Measurement of Magnetization Dynamics in Ferrofluids (opens in a new tab)