Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"Time over Threshold"”.

  1. FPGA-Based System for Radiation Energy Histogram Computation using Time-Over-Threshold

    … that is expensive and limits the number of time-point samples. This thesis presents an FPGA-based system used in the Portable Dosimetry Device (PODD), a compact wireless gamma spectroscopy system for monitoring 177Lu therapy. This thesis focuses on the design and implementation of an …

    washington Repository record for FPGA-Based System for Radiation Energy Histogram Computation using Time-Over-Threshold (opens in a new tab)

  2. A Multi-Time over Threshold Data Acquisition System for Silicon Photomultipliers based Positron Emission Tomography Imaging

    … row column channel combining scheme and employ threshold detection technique to reduce dark noise contribution across the readout channels. The second generation of the readout chip was fabricated in TSMC 65nm Low Power process with a modified front-end interface design. The third generation of …

    washington Repository record for A Multi-Time over Threshold Data Acquisition System for Silicon Photomultipliers based Positron Emission Tomography Imaging (opens in a new tab)

  3. DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS

    … triple alpha source obtaining an overall resolution around 3.5‰. The chip comprises four channels specifically designed for hole signals and one channel for electron signals. The power consumption is around 10 mW per channel as required by the specifications of TRACE. The main …

    milano Repository record for DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS (opens in a new tab)

  4. MALDI and SIMS microscope mode imaging mass spectrometry

    … the throughput of the instrument.</p> <p>Using a Timepix3 camera, the timing precision can be improved by using a more intense trigger, reaching a 4.5 ns full width half maximum (FWHM). Through the use of time-over-threshold data, mass peaks can be reduced from a FWHM of 50 μm to 32 μm, improving …

    oxford Repository record for MALDI and SIMS microscope mode imaging mass spectrometry (opens in a new tab)

  5. Ανίχνευση και μελέτη εκτεταμένων ατμοσφαιρικών καταιονισμών με τη χρήση καινοτόμων ανιχνευτών και αλγορίθμων

    … for the scintillator counters is based in the Time over Threshold (ToT) technique, demanding triple coincidence between the counters of a station, also providing signal as external trigger to the antenna of that station. In order to verify the fidelity of the developed simulation method, …

    greece Repository record for Ανίχνευση και μελέτη εκτεταμένων ατμοσφαιρικών καταιονισμών με τη χρήση καινοτόμων ανιχνευτών και αλγορίθμων (opens in a new tab)

  6. CdTe/CdZnTe pixellated radiation detector

    … this research, three main aspects have been covered in the development and application of these detectors. These broadly describe the fabrication process, characterisation of energy spectrum and imaging performance, and application of these detectors in industrial X-ray tomography. The first …

    glasgow Download PDF for CdTe/CdZnTe pixellated radiation detector (opens in a new tab)

  7. PARTICLE SCINTILLATING TRACKERS: DESIGN AND READ-OUT OF REAL-TIME, LARGE-AREA, HIGHLY SEGMENTED DETECTORS

    … made of water equivalent material for the real-time imaging and tracking of charged particles to be applied in medical diagnostic. The first prototype of the OFFSET tracker was designed with a single X-Y position plane having a sensitive area 20x20 cm^2. It has the great advantage of a read-out …

    catania Repository record for PARTICLE SCINTILLATING TRACKERS: DESIGN AND READ-OUT OF REAL-TIME, LARGE-AREA, HIGHLY SEGMENTED DETECTORS (opens in a new tab)

  8. Low power compact dual mode detectors for nuclear security applications

    … for CLLBC and CLYC respectively. The use of a time-of-flight measurement allowed for the determination of neutron efficiency for the CLLBC, CLYC and EJ-276 materials, as EJ-299-50 was not available at the time of this measurement, with neutron efficiencies of 0.22%±0.05%, 0.31%±0.07% and …

    glasgow Repository record for Low power compact dual mode detectors for nuclear security applications (opens in a new tab) Download PDF for Low power compact dual mode detectors for nuclear security applications (opens in a new tab)

  9. Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy

    The Timepix detector developed by CERN is a novel and sophisticated particle detector. It consists of a semiconductor layer divided into an array of pixels. This array of pixels is bumpbonded to an electronics integrated layer (i.e. the readout chip). Timepix can be used for a wide range of …

    adelaide Repository record for Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy (opens in a new tab)